scholarly journals Molecular diagnosis of scabies using a novel probe-based polymerase chain reaction assay targeting high-copy number repetitive sequences in the Sarcoptes scabiei genome

2021 ◽  
Vol 15 (2) ◽  
pp. e0009149
Author(s):  
Lena Chng ◽  
Deborah C. Holt ◽  
Matt Field ◽  
Joshua R. Francis ◽  
Dev Tilakaratne ◽  
...  

Background The suboptimal sensitivity and specificity of available diagnostic methods for scabies hampers clinical management, trials of new therapies and epidemiologic studies. Additionally, parasitologic diagnosis by microscopic examination of skin scrapings requires sample collection with a sharp scalpel blade, causing discomfort to patients and difficulty in children. Polymerase chain reaction (PCR)-based diagnostic assays, combined with non-invasive sampling methods, represent an attractive approach. In this study, we aimed to develop a real-time probe-based PCR test for scabies, test a non-invasive sampling method and evaluate its diagnostic performance in two clinical settings. Methodology/Principal findings High copy-number repetitive DNA elements were identified in draft Sarcoptes scabiei genome sequences and used as assay targets for diagnostic PCR. Two suitable repetitive DNA sequences, a 375 base pair microsatellite (SSR5) and a 606 base pair long tandem repeat (SSR6), were identified. Diagnostic sensitivity and specificity were tested using relevant positive and negative control materials and compared to a published assay targeting the mitochondrial cox1 gene. Both assays were positive at a 1:100 dilution of DNA from a single mite; no amplification was observed in DNA from samples from 19 patients with other skin conditions nor from house dust, sheep or dog mites, head and body lice or from six common skin bacterial and fungal species. Moderate sensitivity of the assays was achieved in a pilot study, detecting 5/7 (71.4% [95% CI: 29.0% - 96.3%]) of clinically diagnosed untreated scabies patients). Greater sensitivity was observed in samples collected by FLOQ swabs compared to skin scrapings. Conclusions/Significance This newly developed qPCR assay, combined with the use of an alternative non-invasive swab sampling technique offers the possibility of enhanced diagnosis of scabies. Further studies will be required to better define the diagnostic performance of these tests.

1991 ◽  
Vol 66 (04) ◽  
pp. 500-504 ◽  
Author(s):  
H Peretz ◽  
U Seligsohn ◽  
E Zwang ◽  
B S Coller ◽  
P J Newman

SummarySevere Glanzmann's thrombasthenia is relatively frequent in Iraqi-Jews and Arabs residing in Israel. We have recently described the mutations responsible for the disease in Iraqi-Jews – an 11 base pair deletion in exon 12 of the glycoprotein IIIa gene, and in Arabs – a 13 base pair deletion at the AG acceptor splice site of exon 4 on the glycoprotein IIb gene. In this communication we show that the Iraqi-Jewish mutation can be identified directly by polymerase chain reaction and gel electrophoresis. With specially designed oligonucleotide primers encompassing the mutation site, an 80 base pair segment amplified in healthy controls was clearly distinguished from the 69 base pair segment produced in patients. Patients from 11 unrelated Iraqi-Jewish families had the same mutation. The Arab mutation was identified by first amplifying a DNA segment consisting of 312 base pairs in controls and of 299 base pairs in patients, and then digestion by a restriction enzyme Stu-1, which recognizes a site that is absent in the mutant gene. In controls the 312 bp segment was digested into 235 and 77 bp fragments, while in patients there was no change in the size of the amplified 299 bp segment. The mutation was found in patients from 3 out of 5 unrelated Arab families. Both Iraqi-Jewish and Arab mutations were detectable in DNA extracted from blood and urine samples. The described simple methods of identifying the mutations should be useful for detection of the numerous potential carriers among the affected kindreds and for prenatal diagnosis using DNA extracted from chorionic villi samples.


2014 ◽  
Vol 18 (53) ◽  
pp. 1-167 ◽  
Author(s):  
Louise Pankhurst ◽  
Louissa Macfarlane-Smith ◽  
James Buchanan ◽  
Luke Anson ◽  
Kerrie Davies ◽  
...  

BackgroundEvery year approximately 5000–9000 patients are admitted to a hospital with diarrhoea, which in up to 90% of cases has a non-infectious cause. As a result, single rooms are ‘blocked’ by patients with non-infectious diarrhoea, while patients with infectious diarrhoea are still in open bays because of a lack of free side rooms. A rapid test for differentiating infectious from non-infectious diarrhoea could be very beneficial for patients.ObjectiveTo evaluate MassCode multiplex polymerase chain reaction (PCR) for the simultaneous diagnosis of multiple enteropathogens directly from stool, in terms of sensitivity/specificity to detect four common important enteropathogens:Clostridium difficile,Campylobacterspp.,Salmonellaspp. and norovirus.DesignA retrospective study of fixed numbers of samples positive forC. difficile(n = 200),Campylobacterspp. (n = 200),Salmonellaspp. (n = 100) and norovirus (n = 200) plus samples negative for all these pathogens (n = 300). Samples were sourced from NHS microbiology laboratories in Oxford and Leeds where initial diagnostic testing was performed according to Public Health England methodology. Researchers carrying out MassCode assays were blind to this information. A questionnaire survey, examining current practice for infection control teams and microbiology laboratories managing infectious diarrhoea, was also carried out.SettingMassCode assays were carried out at Oxford University Hospitals NHS Trust. Further multiplex assays, carried out using Luminex, were run on the same set of samples at Leeds Teaching Hospitals NHS Trust. The questionnaire was completed by various NHS trusts.Main outcome measuresSensitivity and specificity to detectC. difficile,Campylobacterspp.,Salmonellaspp., and norovirus.ResultsNucleic acids were extracted from 948 clinical samples using an optimised protocol (200Campylobacterspp., 199C. difficile, 60S. enterica, 199 norovirus and 295 negative samples; some samples contained more than one pathogen). Using the MassCode assay, sensitivities for each organism compared with standard microbiological testing ranged from 43% to 94% and specificities from 95% to 98%, with particularly poor performance forS. enterica. Relatively large numbers of unexpected positives not confirmed with quantitative PCR were also observed, particularly forS. enterica,Giardia lambliaandCryptosporidiumspp. As the results indicated thatS. entericadetection might provide generic challenges to other multiplex assays for gastrointestinal pathogens, the Luminex xTag®gastrointestinal assay was also run blinded on the same extracts (937/948 remaining) and on re-extracted samples (839/948 with sufficient material). ForCampylobacterspp.,C. difficileand norovirus, high sensitivities (> 92%) and specificities (> 96%) were observed. ForS. enterica, on the original MassCode/Oxford extracts, Luminex sensitivity compared with standard microbiological testing was 84% [95% confidence interval (CI) 73% to 93%], but this dropped to 46% on a fresh extract, very similar to MassCode, with a corresponding increase in specificity from 92% to 99%. Overall agreement on the per-sample diagnosis compared with combined microbiology plus PCR for the main four/all pathogens was 85.6%/64.7%, 87.0%/82.9% and 89.8%/86.8% for the MassCode assay, Luminex assay/MassCode extract and Luminex assay/fresh extract, respectively. Luminex assay results from fresh extracts implied that 5% of samples did not represent infectious diarrhoea, even though enteropathogens were genuinely present. Managing infectious diarrhoea was a significant burden for infection control teams (taking 21% of their time) and better diagnostics were identified as having major potential benefits for patients.ConclusionsOverall, the Luminex xTag gastrointestinal panel showed similar or superior sensitivity and specificity to the MassCode assay. However, on fresh extracts, this test had low sensitivity to detect a key enteric pathogen,S. enterica; making it an unrealistic option for most microbiology laboratories. Extraction efficiency appears to be a major obstacle for nucleic acid-based tests for this organism, and possibly the whole Enterobacteriaceae family. To improve workflows in service microbiology laboratories, to reduce workload for infection control practitioners, and to improve outcomes for NHS patients, further research on deoxyribonucleic acid-based multiplex gastrointestinal diagnostics is urgently needed.FundingThe Health Technology Assessment programme of the National Institute for Health Research.


Sign in / Sign up

Export Citation Format

Share Document