scholarly journals Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis

PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248827
Author(s):  
Lili He ◽  
Yinghua Sun ◽  
Wei Sheng ◽  
Qiong Yao

Several recent studies demonstrated that lung ultrasound could achieve desired diagnostic accuracy for transient tachypnea of the neonate (TTN). However, the diagnostic performance of lung ultrasound for TTN has not been systematically studied to date. This meta-analysis aimed to investigate the performance of lung ultrasound in diagnosing TTN. The relevant literature was searched in PubMed, Medline, the Cochrane Library, and Embase databases without any restriction in terms of language and time until January 31, 2021. Studies that assessed the diagnostic performance of lung ultrasound for TTN were included. Seven studies with 1514 participants were summarized. The lung ultrasound provided more accurate performance for diagnosing TTN with pooled sensitivity and specificity of 0.67 [95% confidence interval (CI) = 0.63–0.71] and 0.97 (95% CI = 0.95–0.98), respectively. A higher summarized area under the summary receiver operating characteristic curve was observed as 0.9906. Lower sensitivity and area under the curve (AUC) of B-lines for TTN were observed as 0.330 (95% CI = 0.27–0.38) and 0.5000, respectively. Lung ultrasound provided highly accurate AUC, sensitivity, and specificity in detecting TTN. Large-scale studies are warranted in the future to confirm these results.

2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Zhenhong Wei ◽  
Yuanting Li ◽  
Chaojun Wei ◽  
Yonghong Li ◽  
Hui Xu ◽  
...  

Abstract Background One forth whole-world population is infected with Mycobacterium tuberculosis (Mtb), but 90% of them are asymptotic latent infection without any symptoms but positive result in IFN-γ release assay. There is lack of ideal strategy to distinguish active tuberculosis (TB) and latent tuberculosis infection (LTBI). Some scientist had focused on a set of cytokines as biomarkers besides interferon- gamma (IFN-γ) to distinguish active TB and LTBI, but with considerable variance of results. This meta-analysis aimed to evaluate the overall discriminative ability of potential immune molecules to distinguish active TB and LTBI. Methods PubMed, the Cochrane Library, and Web of Science databases were searched to identify studies assessing diagnostic roles of cytokines for distinguishing active TB and LTBI published up to August 2018. The quality of enrolled studies was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). The pooled diagnostic sensitivity and specificity of each cytokine was calculated by using Meta-DiSc software. Area under the summary receiver operating characteristic curve (AUC) was used to summarize the overall diagnostic performance of each biomarker. Results Fourteen studies with 982 subjects met the inclusion criteria, including 526 active TB and 456 LTBI patients. Pooled sensitivity, specificity and AUC for discriminating between active TB and LTBI were analyzed for IL-2 (0.87, 0.61 and 0.9093), IP-10 (0.77, 0.73 and 0.8609), IL-5 (0.64, 0.75 and 0.8533), IL-13 (0.75, 0.71 and 0.8491), IFN-γ (0.67, 0.75 and 0.8031), IL-10 (0.68, 0.74 and 0.7957) and TNF-α (0.67, 0.64 and 0.7783). The heterogeneous subgroup analysis showed that cytokine detection assays, TB incidence, and stimulator with Mtb antigens are main influence factors for their diagnostic performance. Conclusions The meta-analysis showed cytokine production could assist the distinction between active TB and LTBI, IL-2 with the highest overall accuracy. No single biomarker is likely to show sufficiently diagnostic performance due to limited sensitivity and specificity. Further prospective studies are needed to identify the optimal combination of biomarkers to enhanced diagnostic capacity in clinical practice.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sohyun Eun ◽  
Haemin Kim ◽  
Ha Yan Kim ◽  
Myeongjee Lee ◽  
Go Eun Bae ◽  
...  

AbstractWe assessed the diagnostic accuracy of the age-adjusted quick Sequential Organ Failure Assessment score (qSOFA) for predicting mortality and disease severity in pediatric patients with suspected or confirmed infection. We conducted a systematic search of PubMed, EMBASE, the Cochrane Library, and Web of Science. Eleven studies with a total of 172,569 patients were included in the meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio of the age-adjusted qSOFA for predicting mortality and disease severity were 0.69 (95% confidence interval [CI] 0.53–0.81), 0.71 (95% CI 0.36–0.91), and 6.57 (95% CI 4.46–9.67), respectively. The area under the summary receiver-operating characteristic curve was 0.733. The pooled sensitivity and specificity for predicting mortality were 0.73 (95% CI 0.66–0.79) and 0.63 (95% CI 0.21–0.92), respectively. The pooled sensitivity and specificity for predicting disease severity were 0.73 (95% CI 0.21–0.97) and 0.72 (95% CI 0.11–0.98), respectively. The performance of the age-adjusted qSOFA for predicting mortality and disease severity was better in emergency department patients than in intensive care unit patients. The age-adjusted qSOFA has moderate predictive power and can help in rapidly identifying at-risk children, but its utility may be limited by its insufficient sensitivity.


2021 ◽  
Vol 8 ◽  
Author(s):  
Xueyan Yuan ◽  
Ling Liu ◽  
Wei Chang ◽  
Zongsheng Wu ◽  
Lili Huang ◽  
...  

Background: Acute respiratory failure (ARF) is a commonly distressing condition in critically ill patients. Its early recognition and treatment may improve clinical outcomes. Mounting evidence suggests that lung ultrasound (LUS) could be an alternative to chest X-ray (CXR) or computed tomography (CT) for the diagnosis of ARF in critically ill patients. This meta-analysis aimed to determine whether LUS can be an alternative tool used to investigate the cause of ARF or thoracic pathologies associated with the diagnosis of ARF in critically ill patients.Method: A systematic literature search of the PubMed, Web of Science, Embase, and Cochrane Library databases was conducted from inception to March 2020. Two researchers independently screened studies investigating the accuracy of LUS with CXR or CT for adult critically ill patients with ARF. Data with baseline, true positives, false positives, false negatives, and true negatives were extracted. The study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The pooled sensitivity and specificity were obtained using a bivariate model.Results: Eleven studies, including 1,232 patients, were included in the meta-analysis. Most studies were of low quality. LUS had a pooled sensitivity of 92% (95% confidence interval [CI]: 85–96) and a pooled specificity of 98% (95% CI: 94–99). The area under the summary receiver operating characteristic curve was 98% (95% CI: 97–99). The sensitivity and specificity of LUS to identify different pathological types of ARF were investigated. For consolidation (1,040 patients), LUS had a sensitivity of 89% and a specificity of 97%. For pleural effusion (279 patients), LUS had a pooled sensitivity of 95% and a specificity of 99%. For acute interstitial syndrome (174 patients), LUS had a pooled sensitivity of 95% and a specificity of 91%.Conclusions: LUS is an adjuvant tool that has a moderate sensitivity and high specificity for the diagnosis of ARF in critically ill patients.Systematic Review Registration: The study protocol was registered with PROSPERO (CRD42020211493).


2019 ◽  
Vol 35 (5) ◽  
Author(s):  
Juan Qu ◽  
Jizhi Yang ◽  
Ming Chen ◽  
Lihong Cui ◽  
Tianxi Wang ◽  
...  

Background: MicroRNA-21 (miR-21) is one of the oncogenic miRNAs which may be a potential diagnostic biomarker for hepatocellular carcinoma (HCC). Methods: We systematically searched Medline, Embase, the Cochrane Library, ISI Web of Knowledge, Scopus from inception to August 15, 2018, and reference lists of identified primary studies. Two independent investigators extracted patient and study characteristics. The sensitivity and specificity of microRNA-21 for HCC detection and were analyzed with a random effect model. The area under summary receiver operating characteristic curve (AUC) was used to estimate overall test performance. Results: A total of 515 HCC patients, and 338 healthy or chronic hepatitis controls from six published studies were enrolled in this meta-analysis. All articles were published in English with moderate-to-high quality. The overall pooled sensitivity and specificity were 85.2% (73.3% to 88.4%) and 79.2% (68.4% to 87.0%), respectively. The AUC area was 0.89 (95% CI: 0.85-0.91). The studies had moderate heterogeneity (I2=70.11%). None of the subgroups investigated-ethnicity, controls, sample source-could account for the heterogeneity. Conclusion: MiR-21 is a helpful biomarker for early diagnosis of HCC. Nevertheless, the results of the test must be interpreted carefully in the context of medical history, erological tests and imaging examinations for HCC surveillance. doi: https://doi.org/10.12669/pjms.35.5.685 How to cite this:Qu J, Yang J, Chen M, Cui L, Wang T, Gao W, et al. MicroRNA-21 as a diagnostic marker for hepatocellular carcinoma: A systematic review and meta-analysis. Pak J Med Sci. 2019;35(5):---------. doi: https://doi.org/10.12669/pjms.35.5.685 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


2021 ◽  
Vol 49 (2) ◽  
pp. 030006052098670
Author(s):  
Yongcai Lv ◽  
Yanhua Yao ◽  
Qi Liu ◽  
Jingjing Lei

Objective Our aim was to assess the accuracy of angiopoietin-2 (Ang-2) as a prognostic marker for acute pancreatitis (AP) with organ failure (OF). Methods We undertook a systematic search of the PubMed, Cochrane Library, Embase, Chinese Journals Full-text, Wanfang, China Biology Medicine disc, and Weipu databases to identify eligible cohort studies on the predictive value of Ang-2 for AP with OF. The main outcome measures were sensitivity and specificity. The effects were pooled using a bivariate mixed-effects model. Results Six articles with seven case-control studies (n = 650) were included. Pooled sensitivity, specificity, and positive and negative likelihood ratios with 95% confidence intervals (CI) for AP with OF were 0.93 (95%CI: 0.75–0.99), 0.85 (95%CI: 0.75–0.92), 6.40 (95%CI: 3.36–12.19), and 0.08 (95%CI: 0.02–0.36), respectively. The area under the summary receiver operating characteristic curve was 0.95 (95%CI: 0.92–0.96), and the diagnostic odds ratio was 83.18 (95%CI: 11.50–623.17). Subgroup analysis showed that admission time of AP onset (< or ≥24 hours) was a source of overall heterogeneity. Sensitivity analysis supported this finding. Conclusion Ang-2 had high diagnostic accuracy for AP with OF; the best prediction of Ang-2 may be 24 to 72 hours after onset of AP.


2019 ◽  
Vol 61 (7) ◽  
pp. 964-972 ◽  
Author(s):  
Chong Hyun Suh ◽  
Seung Chai Jung ◽  
Se Jin Cho ◽  
Dong-Cheol Woo ◽  
Woo Yong Oh ◽  
...  

Background Hemorrhagic transformation increases mortality and morbidity in patients with acute ischemic stroke. Purpose The purpose of this study is to evaluate the diagnostic performance of magnetic resonance imaging (MRI) for prediction of hemorrhagic transformation in acute ischemic stroke. Material and Methods A systematic literature search of MEDLINE and EMBASE was performed up to 27 July 2018, including the search terms “acute ischemic stroke,” “hemorrhagic transformation,” and “MRI.” Studies evaluating the diagnostic performance of MRI for prediction of hemorrhagic transformation in acute ischemic stroke were included. Diagnostic meta-analysis was conducted with a bivariate random-effects model to calculate the pooled sensitivity and specificity. Subgroup analysis was performed including studies using advanced MRI techniques including perfusion-weighted imaging, diffusion-weighted imaging, and susceptibility-weighted imaging. Results Nine original articles with 665 patients were included. Hemorrhagic transformation is associated with high permeability, hypoperfusion, low apparent diffusion coefficient (ADC), and FLAIR hyperintensity. The pooled sensitivity was 82% (95% confidence interval [CI] 61–93) and the pooled specificity was 79% (95% CI 71–85). The area under the hierarchical summary receiver operating characteristic curve was 0.85 (95% CI 0.82–0.88). Although study heterogeneity was present in both sensitivity (I2=67.96%) and specificity (I2=78.93%), a threshold effect was confirmed. Studies using advanced MRI showed sensitivity of 92% (95% CI 70–98) and specificity of 78% (95% CI 65–87) to conventional MRI. Conclusion MRI may show moderate diagnostic performance for predicting hemorrhage in acute ischemic stroke although the clinical significance of this hemorrhage is somewhat uncertain.


2020 ◽  
Vol 2020 ◽  
pp. 1-15
Author(s):  
Xuefeng Jiang ◽  
Guijuan Zhang ◽  
Jieyan Wu ◽  
Shujun Lin ◽  
Yusheng Liu ◽  
...  

Purpose. The detection of long noncoding RNA (lncRNA) is a novel method for breast cancer diagnosis. The purpose of this meta-analysis was to evaluate the clinical significance of lncRNAs in identification of human breast cancer. Methods. Electronic databases, including PubMed (176), EMBASE (167), Cochrane Library (4), Web of Science (273), CNKI (41), VIP (18), and wanfang (21), were searched for relevant original articles. Diagnostic capacity of lncRNAs was assessed by pooled sensitivity and specificity, area under the summary receiver operating characteristic curve (AUC), diagnostic odds ratio (DOR), and subgroup and meta-regression analysis. Stata and Meta-Disc software were used to conduct the meta-analysis. Results. 33 articles including 4500 cases were identified in our meta-analysis. lncRNAs sustained a high diagnostic efficacy; the pooled sensitivity, specificity, AUC, and DOR of lncRNAs in differentiating BC from controls were 0.74 (95% CI: 0.69-0.78), 0.78 (95% CI: 0.72-0.83), 0.82 (95% CI: 0.79-0.85), and 10.01 (95% CI: 7.13-14.06), respectively. The subgroup analysis showed that the diagnostic efficacy of lncRNAs in Asian populations was higher than that in Caucasians; lncRNAs in BC were lower than those in TNBC and were higher in plasma and serum specimens than in tissues. In addition, heterogeneity was clearly apparent but was not caused by the threshold effect. Conclusion. This meta-analysis suggested that lncRNAs might be promising biomarkers for identifying breast cancer, and its clinical application warrants further investigation.


2019 ◽  
Vol 34 (2) ◽  
pp. 306-314
Author(s):  
Do Hyun Kim ◽  
Youngjun Seo ◽  
Kyung Min Kim ◽  
Seoungmin Lee ◽  
Se Hwan Hwang

Background We evaluated the accuracy of nasal endoscopy in diagnosing chronic rhinosinusitis (CRS) compared with paranasal sinus computed tomography (CT). Methods Two authors independently searched the 5 databases (PubMed, SCOPUS, Embase, the Web of Science, and the Cochrane database) up to March 2019. For all included studies, we calculated correlation coefficients between the endoscopic and CT scores. We extracted data on true-positive and false-positive and true-negative and false-negative results. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool (version 2). Results We included 16 observational or retrospective studies. A high correlation ( r = .8543; 95% confidence interval [CI] [0.7685–0.9401], P < .0001, I2 = 76.58%) between endoscopy and CT in terms of the diagnostic accuracy for CRS was apparent. The odds ratio (Lund–Kennedy endoscopic score ≥1) was 7.915 (95% CI [4.435–14.124]; I2 = 28.361%). The area under the summary receiver operating characteristic curve was 0.765. The sensitivity and specificity were 0.726 (95% CI [0.584–0.834]) and 0.767 (95% CI [0.685–0.849]), respectively. However, high interstudy heterogeneity was evident given the different endoscopic score thresholds used (Lund–Kennedy endoscopic score ≥1 vs 2). In a subgroup analysis of studies using a Lund–Kennedy endoscopic score threshold ≥2, the area under the summary curve was 0.881, and the sensitivity and specificity were 0.874 (95% CI [0.783–0.930]) and 0.793 (95% CI [0.366–0.962]), respectively. Conclusion Nasal endoscopy is a useful diagnostic tool; the Lund–Kennedy score was comparable with that of CT.


2018 ◽  
Vol 17 (5) ◽  
pp. 0-10
Author(s):  
Dahai Xu ◽  
Chang Su ◽  
Liang Sun ◽  
Yuanyuan Gao ◽  
Youjun Li

Introduction and aim. Serum glypican-3 (GPC3) has been explored as a non-invasive biomarker of hepatocellular carcinoma (HCC). However, controversy remains on its diagnostic accuracy. Therefore, we aimed to conduct a systematic review and metaanalysis to evaluate the differential diagnostic accuracy of serum GPC3 between HCC and liver cirrhosis (LC) cases. Material and methods. After the strict filtering and screening of studies from NCBI, PUBMED, Clinical Trials, Cochrane library, Embase, Prospero and Web of Science databases, 11 studies were selected. All studies provided the sensitivity and specificity of GPC3 and the alpha-fetoprotein (AFP) in the HCC and LC diagnosis. The sensitivity and specificity, and the area under the receiver operating characteristic curve (AUC) were determined and compared between GPC3 and AFP, which was set as a positive control. Results. Pooled sensitivity (95% CI) and specificity (95% CI) were 0.55 (0.52-0.58) and 0.58 (0.54-0.61) for GPC3, 0.54 (0.51-0.57) and 0.83 (0.80-0.85) for AFP, and 0.85 (0.81-0.89) and 0.79 (0.73-0.84) for GPC3 + AFP, respectively. The AUCs of GPC3, AFP and GPC3 + AFP were 0.7793, 0.7867 and 0.9366, respectively. GPC3 had a nearly similar sensitivity as AFP, while the specificity and AUC of GPC3 was lower than that of AFP. The combination of GPC3 and AFP yielded a better sensitivity and AUC than GPC3 or AFP. Conclusion. Serum GPC3 is inferior to AFP in the differential diagnosis between HCC and LC. However, the combination of GPC3 and AFP exhibited a much better performance.


2020 ◽  
Vol 22 (2) ◽  
pp. 197 ◽  
Author(s):  
Weiyu Liang ◽  
Huaiyu Wu ◽  
Fajin Dong ◽  
Hongtian Tian ◽  
Jinfeng Xu

Aim: Rotator cuff (RC) tears are considered to be the main reason for shoulder pain. Although ultrasound is a useful method to detect it, its effectiveness when diagnosing RC tears has been a heated discussion. Therefore, we aimed at evaluating RC tears’ ultrasound accuracy by conducting a systemically review and pooled comprehensive analysis.Materials and methods: Relevant articles up to May 2018 were searched from the Cochrane Library, Embase, and Pubmed databases. Either arthroscopy or magnetic resonance imaging (MRI) was considered as a reference standard. The results were estimated by pooled-sensitivity (P-SEN), pooled-specificity (P-SPE), pooled-diagnostic odds ratio (P-DOR), pooled-likelihood ratio+ (PLR+), pooled-likelihood ratio- (P-LR-), and the area under the summary receiver operating characteristic (SROC).Result: We selected seven prospective studies in accordance with the inclusion criteria that covered 554 rotator cuff tears in 868 patients. The P-SEN, P-SPE, P-LR+, P-LR-, P-DOR, area under the SROC curve of diagnostic performance of ultrasound for RC and post-test probability were 95% (95% CI: 88 – 98), 72% (95% CI: 61 – 81), 3.41 (95% CI: 2.40 – 4.84), 0.08 (95% CI: 0.03 – 0.16), 45.31 (95% CI: 21.04 – 97.59), 89% (95% CI: 0.86 – 0.91), and 46% and 2%, respectively.Conclusion: Our metaanalysis demonstrates that ultrasound has a high efficiency for RC tears’ diagnosis. It can be a promising method in patients with suspected RC tears because of its high sensitivity, specificity and diagnostic accuracy.


Sign in / Sign up

Export Citation Format

Share Document