Application o f the approximative X-ray method to a precise determination of the crystallinity o f polyamide-6 and PET-fibres. Part II. The determination of the crystalline structure of polyamide-6 fibres with a diversified orientation

Polimery ◽  
1981 ◽  
Vol 26 (01) ◽  
pp. 7-9
Author(s):  
GRZEGORZ W. URBANCZYK ◽  
RYSZARD DOMAGALA
Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 560
Author(s):  
Alexandra Carvalho ◽  
Mariana C. F. Costa ◽  
Valeria S. Marangoni ◽  
Pei Rou Ng ◽  
Thi Le Hang Nguyen ◽  
...  

We show that the degree of oxidation of graphene oxide (GO) can be obtained by using a combination of state-of-the-art ab initio computational modeling and X-ray photoemission spectroscopy (XPS). We show that the shift of the XPS C1s peak relative to pristine graphene, ΔEC1s, can be described with high accuracy by ΔEC1s=A(cO−cl)2+E0, where c0 is the oxygen concentration, A=52.3 eV, cl=0.122, and E0=1.22 eV. Our results demonstrate a precise determination of the oxygen content of GO samples.


2002 ◽  
Vol 404-407 ◽  
pp. 19-24 ◽  
Author(s):  
Jean Michel Sprauel ◽  
H. Michaud
Keyword(s):  
X Ray ◽  

1996 ◽  
Vol 3 (2) ◽  
pp. 45-48
Author(s):  
E. M. Kil’dyushov ◽  
I. V. Buromsky ◽  
V. M. Rozinov ◽  
L. E. Kuznetsov

The purpose of this report is the determination of the diagnostic reliability of routine radiologic and CT examinations for pelvic injuries in children. The comparative analysis of these examinations and postmortem morphologic studies of pelvic spesimens was performed in 10 children, aged 2-12 years. It was shown that the X-ray method allowed to diagnose only 47.37% and CT method - 76.32% of all real pelvic injuries (by morphological data) in those children. However, the detectability of damage of the structures that formed the anterior pelvic semi-ring was 50% by radiologic examination, and 60% by CT examination, while for the structures forming posterior pelvic semi-ring it was 44.44% and 94.44%, respectively.


2020 ◽  
pp. 58-63
Author(s):  
M. M. Sidorov ◽  
N. I. Golikov ◽  
R. P. Tihonov

The work evaluates the stress deformed state of the section of the interfield gas collecting main, running in permanently frozen grounds. The object of research is a section of a pipeline with an arched discharge formed as a result of loss of stability as a result of thermal erosion of permanently frozen grounds to disturbance of the vegetation cover. The determination of stresses was carried out by the X-ray method using portable equipment. The experimental data were analyzed with the calculated. The calculated data were obtained by measuring the spatial position of the gas pipeline section. The obtained values of the acting stresses and the estimates of the critical indicators of the gas pipeline monitoring section made it possible to reasonably estimate the stress state. The methodology for determining the acting stresses of pipelines using portable X-ray equipment can be successfully applied to estimate the stressed-deformed state of pipeline systems running in the zone of permafrost.


Neurosurgery ◽  
1990 ◽  
Vol 26 (1) ◽  
pp. 102-106 ◽  
Author(s):  
Issam A. Awad ◽  
Elaine Wyllie ◽  
Hans Luders ◽  
Jennifer Ahl

Abstract There is increasing interest in staged corpus callosotomy for intractable generalized epilepsy. At the first procedure, a portion (usually the anterior two-thirds) of the corpus callosum is sectioned. If seizures persist, completion of callosotomy or alternative treatment approaches can be considered. It is obviously important to ascertain that the desired extent of callosotomy was in fact accomplished at the time of initial operation. Our experience and the published literature indicate that the surgeon's impression at operation can be erroneous. We describe a technique of determining extent of corpus callosotomy during the procedure. The magnetic resonance imaging (MRI) scan in the midsagittal plane is used to select the desired extent of callosotomy. That point on the corpus callosum is characterized using simple planar geometry in relation to three anatomic landmarks in that same plane: the glabella, the inion, and the bregma (midline intersection of the coronal suture). The same point along the corpus callosum can then be located on a lateral skull xray using these same three anatomic landmarks. At surgery, an intraoperative lateral skull x-ray is obtained with a marking clip, thereby verifying the actual extent of callosotomy. We have verified the reliability of this scheme in 5 callosotomy procedures and have used this technique for intraoperative localization of midline and parasagittal targets in another 7 cases (3 tumors, 2 aneurysms, and 2 placements of interhemispheric subdural grids). In addition, we reviewed corpus callosum topography on 25 randomly selected MRI scans. A perpendicular line bisecting the glabellainion line intersects the corpus callosum at a point near its two-thirds extent in every case. This allows a quick determination of the approximate two-thirds point along the corpus callosum by skull x-ray alone, without the need of an MRI scan. The use of the new technique and its simple modification for the two-thirds callosotomy allows a precise determination of the extent of corpus callosum section at surgery and should avoid unintended deviations from the desired procedure. (Neurosurgery 26:102-106, 1990)


Computed tomography is a method for obtaining a series of radiographic pictures of contiguous slices through a solid object such as the human body. Each picture is computed from a set of X-ray transmission measurements and represents the distribution of X-ray attenuation in the slice. The high sensitivity of the method to changes in both density and atomic number has resulted in the development of new diagnostic methods in medicine. The limitations of the method are discussed in terms of two particular kinds of application. First, those applications in which a very precise determination of density or atomic number is required, but at low spatial resolution; an example would be the determination of the uniformity of mixture of plastics or metals. The second kind of application is that requiring high spatial resolution as in the detection of cracks and the visualization of internal structures in complicated objects.


2005 ◽  
Vol 19 (03) ◽  
pp. 85-98 ◽  
Author(s):  
S. BELLUCCI

One of the main involvements of the INFN-Laboratori Nazionali di Frascati group in channeling researches is described, i.e. the crystal undulator R & D, with the characterization of the crystal undulator prototypes with SEM and the positron beam. We consider a precise determination of the optimal experimental conditions for channeling of this kind of accelerated particles through such microstructured crystals, as promising candidates for producing X-ray beams.


Sign in / Sign up

Export Citation Format

Share Document