Commutability of external quality assessment materials for serum sodium and potassium measurements

2019 ◽  
Vol 57 (4) ◽  
pp. 465-475 ◽  
Author(s):  
Ying Yan ◽  
Bingqing Han ◽  
Haijian Zhao ◽  
Rong Ma ◽  
Jing Wang ◽  
...  

Abstract Background The commutability of electrolyte trueness verification materials (ETVs) and commercial general chemistry materials (GCs) was evaluated to investigate their suitability for use in an external quality assessment (EQA) program for serum sodium and potassium measurements. Methods Eighty fresh individual human samples (40 for sodium measurements and 40 for potassium measurements), six ETVs and three GCs were analyzed by five routine methods (validated methods) and by inductively coupled plasma mass spectrometry reference methods (comparative methods) for the determination of sodium and potassium. The commutability was analyzed according to Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol and difference in bias approach, respectively. The linearity, bias and imprecision of the routine methods were also assessed according to CLSI guidelines. Results According to EP14-A3 protocol, ETVs were commutable for all assays, and GCs were commutable for 3/5 assays for sodium. ETVs were commutable in most assays except Cobas C501, while GCs showed no commutability except in case of AU5821 for potassium. According to a difference in bias approach, the commutability of ETVs was inconclusive for most routine assays for both sodium and potassium, and GCs were inconclusive for sodium and non-commutable for potassium in most routine assays. The routine methods exhibited excellent linearities and precisions. The majority and minority of relative biases between the routine and reference methods were beyond the bias limits for sodium and potassium, respectively. Conclusions Superiority in the commutability of ETVs over GCs was observed among the sodium and potassium assays whichever evaluation approach was applied.

1993 ◽  
Vol 39 (6) ◽  
pp. 993-1000 ◽  
Author(s):  
D Stöckl ◽  
H Reinauer

Abstract In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.


2020 ◽  
Author(s):  
Daniel Bůžek ◽  
Slavomír Adamec ◽  
Kamil Lang ◽  
Jan Demel

<div><p>UiO-66 is a zirconium-based metal-organic framework (MOF) that has numerous applications. Our group recently determined that UiO-66 is not as inert in aqueous dispersions as previously reported in the literature. The present work therefore assessed the behaviour of UiO-66 in buffers: 2-amino-2-(hydroxymethyl)-1,3-propanediol (TRIS), 4-(2-hydroxyethyl)piperazine-1-ethane sulfonic acid (HEPES), N-ethylmorpholine (NEM) and phosphate buffer (PB), all of which are commonly used in many UiO-66 applications. High pressure liquid chromatography and inductively coupled plasma mass spectrometry were used to monitor degradation of the MOF. In each buffer, the terephthalate linker was released to some extent, with a more pronounced leaching effect in the saline forms of these buffers. The HEPES buffer was found to be the most benign, whereas NEM and PB should be avoided at any concentration as they were shown to rapidly degrade the UiO-66 framework. Low concentration TRIS buffers are also recommended, although these offer minimal buffer capacity to adjust pH. Regardless of the buffer used, rapid terephthalate release was observed, indicating that the UiO-66 was attacked immediately after mixing with the buffer. In addition, the dissolution of zirconium, observed in some cases, intensified the UiO-66 decomposition process. These results demonstrate that sensitive analytical techniques have to be used to monitor the release of MOF components so as to quantify the stabilities of these materials in liquid environments.</p></div>


2019 ◽  
Author(s):  
Ingo Strenge ◽  
Carsten Engelhard

<p>The article demonstrates the importance of using a suitable approach to compensate for dead time relate count losses (a certain measurement artefact) whenever short, but potentially strong transient signals are to be analysed using inductively coupled plasma mass spectrometry (ICP-MS). Findings strongly support the theory that inadequate time resolution, and therefore insufficient compensation for these count losses, is one of the main reasons for size underestimation observed when analysing inorganic nanoparticles using ICP-MS, a topic still controversially discussed.</p>


Sign in / Sign up

Export Citation Format

Share Document