scholarly journals Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode

2021 ◽  
Vol 19 (1) ◽  
pp. 843-854
Author(s):  
Agata Skorupa ◽  
Slawomir Michalkiewicz ◽  
Magdalena Jakubczyk

Abstract A simple, highly sensitive, and selective differential pulse voltammetry method for the determination of α-lipoic acid (LA) in pharmaceutical preparations was developed and validated. The method is based on a quasi-reversible, diffusion-controlled, one-electron anodic oxidation of LA on a boron-doped diamond electrode (BDDE) in a McIlvaine (citrate-phosphate, C-PB) buffer solution at pH 3.0. For the first time, this environment was used for LA determination. A linear calibration curve was obtained within the concentration range 5.82 × 10−8 to 4.00 × 10−4 mol L−1 with a correlation coefficient of 0.9999. The limits of detection was estimated to be 1.94 × 10−8 mol L−1, which is one of the lowest values characteristic of voltammetric and chromatographic methods of LA determination. The proposed procedure is sensitive, accurate, and precise. Its utility was demonstrated in the determination of LA in pharmaceuticals without the need for its separation from the matrices. The results were comparable to those obtained by high performance liquid chromatography reference method and were in good accordance with the once declared by manufacturers. Thus, our method can be considered as an alternative to the dominant chromatographic determinations of α-LA in real samples.

2015 ◽  
Vol 98 (6) ◽  
pp. 1535-1541 ◽  
Author(s):  
Biljana Nigović ◽  
Ana Mornar ◽  
Mario Završki

Abstract A boron-doped diamond electrode provided a sensitive and cost-effective sensing platform for detection and quantitative determination of novel beta(1)-adrenergic receptor antagonist nebivolol. The net square-wave voltammetric response at 1.31 V related to the oxidation of nebivolol was obtained in Britton-Robinson buffer solution at pH 8. It increased linearly with the drug concentration in the range of 2.5 × 10–7 to 1.5 × 10–5 M. The LOD attained was 3.2 × 10–8 M. The practical analytical approach was illustrated by high speed quantification of nebivolol in a commercial pharmaceutical formulation. The RP-HPLC was selected as a comparative method for evaluating the proposed electroanalytical method. The newly developed method at the unmodified electrode surface was faster and simpler in comparison with HPLC (the retention time was 17.6 min), and only 6 s was necessary for direct voltammetric measurement in the potential range from 0.5 to 1.7 V with a 2 mV potential step and pulse frequency of 100 Hz.


2018 ◽  
Vol 149 (9) ◽  
pp. 1701-1708 ◽  
Author(s):  
Renáta Šelešovská ◽  
Barbora Kränková ◽  
Michaela Štěpánková ◽  
Pavlína Martinková ◽  
Lenka Janíková ◽  
...  

2013 ◽  
Vol 25 (7) ◽  
pp. 1734-1741 ◽  
Author(s):  
Ana Paula Pires Eisele ◽  
Débora Nóbile Clausen ◽  
César Ricardo Teixeira Tarley ◽  
Luiz Henrique Dall'Antonia ◽  
Elen Romão Sartori

2013 ◽  
Vol 39 ◽  
pp. 41-46 ◽  
Author(s):  
Polyana Fernandes Pereira ◽  
Mariana Cardoso Marra ◽  
Amanda Barbosa Lima ◽  
Wallans Torres Pio dos Santos ◽  
Rodrigo Alejandro Abarza Munoz ◽  
...  

Talanta ◽  
2009 ◽  
Vol 78 (3) ◽  
pp. 748-752 ◽  
Author(s):  
Bruna Cláudia Lourenção ◽  
Roberta Antigo Medeiros ◽  
Romeu C. Rocha-Filho ◽  
Luiz Henrique Mazo ◽  
Orlando Fatibello-Filho

2015 ◽  
Vol 744 ◽  
pp. 37-44 ◽  
Author(s):  
L’ubomír Švorc ◽  
Kristína Cinková ◽  
Anchalee Samphao ◽  
Dalibor M. Stanković ◽  
Eda Mehmeti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document