Reference intervals and reliability of cavum septi pellucidi volume measurements by three-dimensional ultrasound between 19 and 24 weeks’ gestation

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Aslim Cinar ◽  
Mekin Sezik ◽  
Serenat Eris Yalcin ◽  
And Yavuz

AbstractObjectivesA small or a large cavum septi pellucidi (CSP) during routine second trimester sonography may suggest abnormal cerebral development. Therefore, determination of CSP volume with three-dimensional (3D) ultrasound can be valuable. For this purpose, we sought to evaluate the reference ranges and measurement reliability of CSP volume by Virtual Organ Computer-aided AnaLysis (VOCAL).MethodsVOCAL software was used to calculate the CSP volume from transabdominal multiplanar datasets of 99 structurally normal fetal ultrasound examinations between 19 and 24 weeks of gestation. Linear regression was utilized to determine reference intervals for CSP volumes as a function of gestational week (GW). Agreement among three evaluators with different proficiency levels (obstetrics and gynecology resident, perinatology fellow, and perinatologist) was assessed, using intraclass correlation coefficients (ICC) and 95% confidence intervals (CI).ResultsCSP volume and gestational age was positively correlated (r2=0.383, p=0.0001), represented by the following equation: 0.058–(1.016 x GW). Interobserver agreement between perinatologist and fellow was relatively high (ICC, 0.78; 95% CI, 0.70–0.85), whereas limited ultrasound experience (resident) was associated with fair agreement with non-novice observers (ICC for resident and perinatologist, 0.50; 95% CI, 0.29–0.65 and ICC for resident and fellow, 0.57; 95% CI, 0.38–0.71).ConclusionsReference ranges of CSP volumes using VOCAL from 19 0/6 through 24 6/7 weeks of gestation were established. A first-degree model to estimate CSP volume as a function of gestational age was also constructed. CSP volumetry seems reliable when evaluated by an examiner with particular 3D sonography experience.

2012 ◽  
Vol 51 (03) ◽  
pp. 73-78 ◽  
Author(s):  
A. Darr ◽  
J.-H. Schierz ◽  
E. Schleußner ◽  
S. Wiegand ◽  
T. Opfermann ◽  
...  

SummaryPurpose: It has recently become possible to generate and archive three-dimensional ultrasound (3D-US) volume data with the DICOM standard Enhanced Ultrasound Volume Storage (EUVS). The objective of this study was to examine the application of the EUVS standard based on the example of thyroid ultrasound. Patients, methods: 32 patients, who were referred for thyroid diagnosis, were given a 3D-US examination of the thyroid gland (GE Voluson E8, convex 3D probe RAB4–8-D). The 3D data sets were exported to EUVS. Necessary additions to DICOM entries and transformation into an established DICOM standard were carried out. The visual assessment and volume measurements were performed by two experts on nuclear medicine using standard software in our hospital. Results: In 24/32 (75%) of the patients, the whole organ was successfully recorded in a single 3D scan; in 8/32 (25%), only part of organ could be covered. In all cases, 3D-US data could be exported and archived. After supplementing the DICOM entry Patient Orientation and transformation into the DICOM PET format, 3D-US data could be displayed in the correct orientation and size at any viewing workstation and any web browser-based PACS viewer. Afterwards, 3D processing such as multiplanar reformation, volumetric measurements and image fusion with data of other cross sectional modalities could be performed. The intraclass correlation of the volume measurements was 0,94 and the interobserver variability was 5.7%. Conclusion: EUVS allows the generation, distribution and archiving of 3D-US data of the thyroid, facilitates a second reading by another physician and creates conditions for advanced 3D processing using routine software


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
C. O. Figueira ◽  
F. G. Surita ◽  
M. S. Dertkigil ◽  
S. L. Pereira ◽  
J. R. Bennini ◽  
...  

Objective. To elaborate curves of longitudinal reference intervals of pulsatility index (PI) and systolic velocity (SV) for uterine (UtA), umbilical (UA), and middle cerebral arteries (MCA), in low risk pregnancies. Methods. Doppler velocimetric measurements of PI and SV from 63 low risk pregnant women between 16 and 41 weeks of gestational age. Means (±SD) for intervals of gestational age and percentiles 5, 50, and 95 were calculated for each parameter. The Intraclass Correlation Coefficients (ICC) were also estimated for assessing intra- and intervariability of measurements. Results. Mean PI of UtA showed decreasing values during pregnancy, but no regular pattern was identified for mean SV. For UA, PI decreased and SV increased along gestation. MCA presented PI increasing values until 32–35 weeks. SV showed higher levels with increasing gestation. High ICC values indicated good reproducibility. Conclusions. Reference intervals for the assessment of SV and PI of UtA, UA, and MCA were established. These reference intervals showed how a normal pregnancy is expected to progress regarding these Doppler velocimetric parameters and are useful to follow high risk pregnancies. The comparison between results using different curves may provide insights about the best patterns to be used.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pieter-Jan Verhelst ◽  
H. Matthews ◽  
L. Verstraete ◽  
F. Van der Cruyssen ◽  
D. Mulier ◽  
...  

AbstractAutomatic craniomaxillofacial (CMF) three dimensional (3D) dense phenotyping promises quantification of the complete CMF shape compared to the limiting use of sparse landmarks in classical phenotyping. This study assesses the accuracy and reliability of this new approach on the human mandible. Classic and automatic phenotyping techniques were applied on 30 unaltered and 20 operated human mandibles. Seven observers indicated 26 anatomical landmarks on each mandible three times. All mandibles were subjected to three rounds of automatic phenotyping using Meshmonk. The toolbox performed non-rigid surface registration of a template mandibular mesh consisting of 17,415 quasi landmarks on each target mandible and the quasi landmarks corresponding to the 26 anatomical locations of interest were identified. Repeated-measures reliability was assessed using root mean square (RMS) distances of repeated landmark indications to their centroid. Automatic phenotyping showed very low RMS distances confirming excellent repeated-measures reliability. The average Euclidean distance between manual and corresponding automatic landmarks was 1.40 mm for the unaltered and 1.76 mm for the operated sample. Centroid sizes from the automatic and manual shape configurations were highly similar with intraclass correlation coefficients (ICC) of > 0.99. Reproducibility coefficients for centroid size were < 2 mm, accounting for < 1% of the total variability of the centroid size of the mandibles in this sample. ICC’s for the multivariate set of 325 interlandmark distances were all > 0.90 indicating again high similarity between shapes quantified by classic or automatic phenotyping. Combined, these findings established high accuracy and repeated-measures reliability of the automatic approach. 3D dense CMF phenotyping of the human mandible using the Meshmonk toolbox introduces a novel improvement in quantifying CMF shape.


2009 ◽  
Vol 43 (4) ◽  
pp. 327-331 ◽  
Author(s):  
Jeff Hargrove ◽  
Eric D. Zemper ◽  
Mary L. Jannausch

Abstract A novel technique for achieving plethysmography measurements utilizing noncontact laser displacement sensors is described. This method may have utility in measuring respiratory and pulmonary function similar to that of respiratory inductive plethysmography. The authors describe the apparatus and method and provide results of a validation study comparing respiratory excursion data obtained by (1) the laser sensor technique, (2) standard respiratory inductive plethysmography (RIP), and (3) lung volume measurements determined by pressure variations in a control volume. Six healthy volunteers (five female, one male, ages ranging from 19 to 23 years) were measured for tidal breathing excursions simultaneously via all three measurement techniques. Results: Excellent correlation between the techniques was shown. Pairwise comparisons among all three measurement techniques across all subjects showed intraclass correlation coefficients of 0.995 in each case. These results indicate the laser plethysmograph (LP) system provides results that are, at a minimum, equivalent to those of the RIP at the two sites commonly measured by RIP. Use of the LP system has the potential to provide much more extensive and precise measurements of chest wall function and the respiratory musculature.


2017 ◽  
Vol 45 (9) ◽  
Author(s):  
Haitham A. Torky ◽  
Asem A. Moussa ◽  
Ali M. Ahmad ◽  
Osama Dief ◽  
Manar A. Eldesoouky ◽  
...  

AbstractAim of work:To determine whether fetal volume (FV) measured by three-dimensional (3D) ultrasound was able to detect fetuses at risk of low birth weight (primary outcome) and/or preterm labor (secondary outcome).Methods:One hundred pregnant women carrying a singleton living pregnancy who were sure of dates, and had a dating scan, with gestational age between 11 weeks and 13 weeks+6 days coming for routine first trimester nuchal translucency (NT) were examined by both two-dimensional (2D) and 3D ultrasound (Vocal System) for crown-rump length (CRL) and FV then followed up regularly every 4 weeks until 28 weeks then biweekly until 36 weeks then weekly until delivery both clinically and by ultrasound biometry.Findings:Eighty-seven cases had a normal outcome, while the remaining 13 cases had either preterm labor (four cases) or low-birth weight (nine cases). FV positively correlated with CRL (P=0.026), gestational age in weeks (P=0.002), neonatal body weight in grams (P=0.018) and neonatal body length at birth (P=0.04). A mean FV of 8.3 mmConclusion:3D assessment of FV in the first trimester provides an accurate method for predicting pregnancy outcome namely low birth weight and neonatal complications, however, it is a better positive predictor than a negative one.


2019 ◽  
Vol 90 (3) ◽  
pp. 397-404 ◽  
Author(s):  
Zhuoxing Xiao ◽  
Zijin Liu ◽  
Yan Gu

ABSTRACT Objective To evaluate three-dimensional (3D) accuracy and reliability of nonradiographic dentofacial images integrated with a two-step method. Methods 3D facial images, cone-beam computed tomography (CBCT) images and digital maxillary dental casts were obtained from 20 pre-orthodontic subjects. Digital dental casts were integrated into 3D facial images using a two-step method based on the anterior tooth area. 3D coordinate values of five dental landmarks were identified in both dentofacial images and CBCT images. The accuracy of the integration method was assessed with paired t-tests between dentofacial images and CBCT-based reference standards. Intraclass correlation coefficients (ICCs) were assessed for the reliability of dentofacial images and CBCT-based images. Analysis of variance and Kruskal-Wallis tests evaluated the accuracy of the method in different dimensions. Results There was no statistical difference between dentofacial images and CBCT reference standards in both translational and rotational dimensions (P &gt; .05). Translational mean absolute errors for full dentitions were within 0.42 mm and ICCs were over 0.998 in x, y, and z directions. Rotational mean absolute errors for full dentitions were within 0.92° and ICCs over 0.734 in pitch, yaw, and roll orientations. Integration errors were significantly greater in the first molar, z-translation, and pitch rotation (P &lt; .05). Conclusions Integrating 3D dentofacial images with the two-step method is precise and acceptable for clinical diagnostics and scientific purposes. Errors were greater in the molar region, z-translation, and pitch rotation.


2001 ◽  
Vol 21 (10) ◽  
pp. 1146-1150 ◽  
Author(s):  
Jussi Hirvonen ◽  
Kjell Någren ◽  
Jaana Kajander ◽  
Jarmo Hietala

[11C]SCH 23390 is a standard ligand for positron emission tomography (PET) studies on striatal dopamine D1 receptors. Its usefulness for cortical D1 receptor quantification in human PET studies has been questioned but has not been addressed previously. The authors tested the reproducibility of [11C]SCH 23390 binding potential (BP) in cortical areas in five healthy volunteers using three-dimensional PET. Measurement of D1 receptor BP was reproducible in basal ganglia, as well as in all cortical areas studied (intraclass correlation coefficients between 0.81 and 0.92). The absolute variability in cortical areas was 9.21% ± 0.07%. The reproducibility of cortical D1 receptor BP measurement with [11C]SCH 23390 is equal to that observed with a more recent D1 -ligand, [11C]NNC 112. [11C]NNC 112 produces slightly higher specific-to-nonspecific binding ratios but has markedly slower kinetics resulting in a need for a longer scan time. These aspects should be considered when designing studies on the cortical D1 -like receptors.


2006 ◽  
Vol 43 (2) ◽  
pp. 129-137 ◽  
Author(s):  
Emeka Nkenke ◽  
Bernhard Lehner ◽  
Manuel Kramer ◽  
Gerd Haeusler ◽  
Stefanie Benz ◽  
...  

Objective To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Design Technical report, reliability study. Setting Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. Patients The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Main Outcome Measures Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. Results The method errors were less than 1 mm for distances and less than 1.5° for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. Conclusion The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.


2016 ◽  
Vol 86 (6) ◽  
pp. 1004-1009 ◽  
Author(s):  
Asli Baysal ◽  
Ahmet Oguz Sahan ◽  
Mehmet Ali Ozturk ◽  
Tancan Uysal

ABSTRACT Objective: To evaluate the intraexaminer repeatability and interexaminer reproducibility of soft tissue landmarks on three-dimensional (3-D) stereophogrammetric images. Materials and Methods: Thirty-four stereophotogrammetric images were taken and 19 soft tissue points were identified. The images were obtained using the 3-DMD Face (3-DMD TM Ltd, Atlanta, Ga) system. Two examiners marked 34 images manually with a mouse-driven cursor 4 weeks apart. Intraexaminer marking differences were calculated and classified as &lt;0.5 mm, 0.5–1 mm, and &gt;1 mm. Intraclass correlation coefficients were calculated for intraexaminer reliability. A paired-samples t-test was used to evaluate the difference between the examiners. Interexaminer reproducibility was evaluated by kappa analysis. Statistical significance was set at P &lt; .05. Results: Only one landmark (labiale superior) had an intraexaminer marking difference less than 0.5 mm. Existing landmarks had an intraexaminer difference less than 1 mm, but higher than 0.5 mm. The intraclass correlation coefficients (ICCs) indicated good intraexaminer repeatability for both observers. The ICC range for examiners 1 and 2 was 0.986–1.000 and 0.990–1.000, respectively. Kappa scores showed good interexaminer agreement, especially on the z-axis. Conclusions: Except labiale superior, the soft tissue landmarks used in this study were shown to have moderate reproducibility, but the difference between the landmarks was less than 1 mm, and they had clinically acceptable reproducibility.


2018 ◽  
Vol 20 (4) ◽  
pp. 480 ◽  
Author(s):  
Martin Freesmeyer ◽  
Leonard Knichel ◽  
Christian Kuehnel ◽  
Thomas Winkens

Aims: Thyroid volume has to be measured in goiters prior to radioiodine treatment to calculate the needed amount of radioactivity. Modern clinical equipment for ultrasonography shows the trend to smaller probes, so that larger goiters do not fit any longer into the probe’s field of view. This study evaluated the feasibility and accuracy of stitching procedures applied to thyroid volumetric analysis performed using three-dimensional ultrasound (3D-US).Material and methods: Ad hoc thyroid phantoms of different shapes (regular, nodular, thickened isthmus) and volumes (ranging between 50 and 400 mL) were developed. In 15 such phantoms the left and right lobes were separately scanned, and the 3D-US datasets were then assembled (stitched) using predefined landmarks and dedicated software. Volumetric analysis was then assessed via a conventional ellipsoid model (em) and manual tracing (mt). The correlation of measured and reference volumes was determined using Pearson’s correlation coefficients and Bland and Altman limits of agreement.Results: The results showed a high level of agreement (with correlation coefficients ranging from 0.974 to 0.999) for all shapes and volumes tested, including the largest volume of 400 mL. The mt method, although more time consuming, proved superior to the em.Conclusions: Stitching-mediated thyroid volumetric analysis is accurate, and its clinical performance should be investigated in future studies