Comparison of Kettlebell Swings and Treadmill Running at Equivalent Rating of Perceived Exertion Values

2012 ◽  
Vol 26 (5) ◽  
pp. 1203-1207 ◽  
Author(s):  
Caleb R. Hulsey ◽  
David T. Soto ◽  
Alexander J. Koch ◽  
Jerry L. Mayhew
Folia Medica ◽  
2021 ◽  
Vol 63 (4) ◽  
pp. 502-510
Author(s):  
Oyéné Kossi ◽  
Justine Lacroix ◽  
Maxence Compagnat ◽  
Jean Christophe Daviet ◽  
Stéphane Mandigout

Aim: To test the validity of Borg’s 6–20 rating of perceived exertion scale in assessing the exertion intensity over a multi-activity session in young and older adults.Materials and methods: This cross-sectional study included 56 healthy participants. All participants underwent a single session of activities including working on a computer, treadmill walking, biking, and treadmill running. Results: Results showed a non-significant correlation between the overall perceived exertion and energy expenditure in young people (Rho=−0.05, p=0.75) and in older adults (Rho=−0.05, p=0.78) for the whole session. However, results showed that older adults perceived significantly higher exertion compared to young people while working on a computer, walking and running, whereas they presented lower energy expenditure while resting and working on a computer. Conclusions: Combining the perceived exertion method with other commonly used methods to estimate exercise intensity would be recommended for older adults.


2020 ◽  
pp. 1-5
Author(s):  
Megan Wagner ◽  
Kevin D. Dames

Context: Bodyweight-supporting treadmills are popular rehabilitation tools for athletes recovering from impact-related injuries because they reduce ground reaction forces during running. However, the overall metabolic demand of a given running speed is also reduced, meaning athletes who return to competition after using such a device in rehabilitation may not be as fit as they had been prior to their injury. Objective: To explore the metabolic effects of adding incline during bodyweight-supported treadmill running. Design: Cross-sectional. Setting: Research laboratory. Participants: Fourteen apparently healthy, recreational runners (6 females and 8 males; 21 [3] y, 1.71 [0.08] m, 63.11 [6.86] kg). Interventions: The participants performed steady-state running trials on a bodyweight-supporting treadmill at 8.5 mph. The control condition was no incline and no bodyweight support. All experimental conditions were at 30% bodyweight support. The participants began the sequence of experimental conditions at 0% incline; this increased to 1%, and from there on, 2% incline increases were introduced until a 15% grade was reached. Repeated-measures analysis of variance was used to compare all bodyweight-support conditions against the control condition. Main Outcome Measures: Oxygen consumption, heart rate, and rating of perceived exertion. Results: Level running with 30% bodyweight support reduced oxygen consumption by 21.6% (P < .001) and heart rate by 12.0% (P < .001) compared with the control. Each 2% increase in incline with bodyweight support increased oxygen consumption by 6.4% and heart rate by 3.2% on average. A 7% incline elicited similar physiological measures as the unsupported, level condition. However, the perceived intensity of this incline with bodyweight support was greater than the unsupported condition (P < .001). Conclusions: Athletes can maintain training intensity while running on a bodyweight-supporting treadmill by introducing incline. Rehabilitation programs should rely on quantitative rather than qualitative data to drive exercise prescription in this modality.


2001 ◽  
Vol 33 (11) ◽  
pp. 1953-1958 ◽  
Author(s):  
MIKE DOHERTY ◽  
PAUL M. SMITH ◽  
MICHAEL G. HUGHES ◽  
DAVID COLLINS

2013 ◽  
Vol 38 (12) ◽  
pp. 1211-1216 ◽  
Author(s):  
Alexis R. Mauger ◽  
Alan J. Metcalfe ◽  
Lee Taylor ◽  
Paul C. Castle

The novel self-paced, cycle-based maximal oxygen uptake (V̇O2max) test (SPV) has been shown to produce higher V̇O2max values than standard graded exercise test (GXT) protocols. This study sought to ascertain whether these observations would also be apparent in a self-paced, treadmill-based test design. Fourteen trained male runners performed a standard GXT on a motorised treadmill and a self-paced V̇O2max test on a nonmotorised treadmill in a counter-balanced design. The GXT included a plateau verification and was designed to last between 8 and 12 min. The self-paced test included 5 × 2 min stages and allowed participants to set their own running speed based on fixed increments in rating of perceived exertion. Significantly higher V̇O2max values (t[13] = 3.71, p = 0.003) were achieved in the self-paced test (64.4 ± 7.3 mL·kg−1·min−1) compared with the GXT (61.3 ± 7.3 mL·kg−1·min−1), and 13 of the 14 participants achieved the same or higher V̇O2max values in the self-paced test. Higher (p = 0.01) maximum heart rates were observed in the GXT (191 ± 10 beats·min−1 vs. 187 ± 7 beats·min−1), but no differences were observed in any other recorded variables. The self-paced V̇O2max test may provide a more valid means of measuring V̇O2max than the GXT and suggests that a V̇O2 plateau during a GXT does not always signify achievement of a definitive V̇O2max. These results provide further support that self-paced V̇O2max testing produces higher values for maximal oxygen uptake.


Proceedings ◽  
2020 ◽  
Vol 49 (1) ◽  
pp. 30
Author(s):  
Jos Goudsmit ◽  
Stella Lo Giudici ◽  
Janine Herweijer ◽  
Steven Vos

Within this study the aim is to measure running workload and relevant running technique key points on varying cadence in recreational runners using a custom build sensor system ‘Nodes’. Seven participants ran on a treadmill at a self-chosen comfortable speed. Cadence was randomly guided by a metronome using 92%, 96%, 100%, 104%, and 108% of the preferred cadence in 2-min trials. Workload was measured by collecting the heart rate and the rating of perceived exertion (RPE 1 to 10) scores. Heart rate data shows that the 100% cadence trial was most economical with a relative heart rate of 99.2%. The 108% cadence trial had the lowest relative RPE score with 96.2%. The sample rate of the Nodes system during this experiment was too low to analyze the key points. Three requirements are proposed for the further engineering of a wearable running system, (i) sampling frequency of minimal 50 Hz, (ii) step-by-step analysis, and (iii) collecting workload in the heart rate and RPE.


Author(s):  
Nicolas Berger ◽  
Daniel Cooley ◽  
Michael Graham ◽  
Claire Harrison ◽  
Russ Best

Ultra-running comprises running events longer than a marathon (>42.2 km). The prolonged duration of ultra-running leads to decrements in most or all physiological parameters and considerable energy expenditure (EE) and energy deficits. SG, 47 years, 162.5 cm, 49 kg, VO2max 4 mL/kg/min−1/2.37 L/min−1, ran continuously for 7 days on a treadmill in 3 h blocks followed by 30 min breaks and slept from 1–5 a.m. Heart rate (HR) oxygen uptake (VO2), rating of perceived exertion, weight, blood lactate (mmol·L−1), haemoglobin (g·dL), haematocrit (%) and glucose (mmol·L−1), and nutrition and hydration were recorded. SG ran for 17.5 h/day, covering ~120 km/day at ~7 km/h. Energy expenditure for each 24 h period was 6878 kcal/day and energy intake (EI) was 2701 kcal/day. EE was 382 kcal/h, with 66.6% from fat and 33.4% from carbohydrate oxidation. 7 day EI was 26,989 kcal and EE was 48,147 kcal, with a total energy deficit (ED) of 21,158 kcal. Average VO2 was 1.2 L·min−1/24.7 mL·kg·min−1, Respriatory echange ratio (RER) 0.80 ± 0.03, HR 120–125 b·min−1. Weight increased from 48.6 to 49.5 kg. Haemoglobin decreased from 13.7 to 11 g·dL and haematocrit decreased from 40% to 33%. SG ran 833.05 km. SG exhibits an enhanced fat metabolism through which she had a large daily ED. Her success can be attributed to a combination of physiological and psychological factors.


Author(s):  
Ian Craig Perkins ◽  
Sarah Anne Vine ◽  
Sam David Blacker ◽  
Mark Elisabeth Theodorus Willems

We examined the effect of New Zealand blackcurrant (NZBC) extract on high-intensity intermittent running and postrunning lactate responses. Thirteen active males (age: 25 ± 4 yrs, height: 1.82 ± 0.07 m, body mass: 81 ± 14 kg, V̇O2max: 56 ± 4 ml∙kg-1∙min-1, v V̇O2max: 17.6 ± 0.8 km∙h-1) performed a treadmill running protocol to exhaustion, which consisted of stages with 6 × 19 s of sprints with 15 s of low-intensity running between sprints. Interstage rest time was 1 min and stages were repeated with increasing sprint speeds. Subjects consumed capsuled NZBC extract (300 mg∙day-1 CurraNZ; containing 105 mg anthocyanin) or placebo for 7 days (double-blind, randomized, crossover design, wash-out at least 14 days). Blood lactate was collected for 30 min postexhaustion. NZBC increased total running distance by 10.6% (NZBC: 4282 ± 833 m, placebo: 3871 ± 622 m, p = .02), with the distance during sprints increased by 10.8% (p = .02). Heart rate, oxygen uptake, lactate and rating of perceived exertion were not different between conditions for the first 4 stages completed by all subjects. At exhaustion, blood lactate tended to be higher for NZBC (NZBC: 6.01 ± 1.07 mmol∙L-1, placebo: 5.22 ± 1.52 mmol∙L-1, p = .07). There was a trend for larger changes in lactate following 15 min (NZBC: -2.89 ± 0.51 mmol∙L-1, placebo: -2.46 ± 0.39 mmol∙L-1, p = .07) of passive recovery. New Zealand blackcurrant extract (CurraNZ) may enhance performance in sports characterized by high-intensity intermittent exercise as greater distances were covered with repeated sprints, there was higher lactate at exhaustion, and larger changes in lactate during early recovery after repeated sprints to exhaustion.


2021 ◽  
pp. bjsports-2020-103758
Author(s):  
Simon Driver ◽  
Megan Reynolds ◽  
Katelyn Brown ◽  
Jakob L Vingren ◽  
David W Hill ◽  
...  

ObjectivesTo (1) determine if wearing a cloth face mask significantly affected exercise performance and associated physiological responses, and (2) describe perceptual measures of effort and participants’ experiences while wearing a face mask during a maximal treadmill test.MethodsRandomised controlled trial of healthy adults aged 18–29 years. Participants completed two (with and without a cloth face mask) maximal cardiopulmonary exercise tests (CPETs) on a treadmill following the Bruce protocol. Blood pressure, heart rate, oxygen saturation, exertion and shortness of breath were measured. Descriptive data and physical activity history were collected pretrial; perceptions of wearing face masks and experiential data were gathered immediately following the masked trial.ResultsThe final sample included 31 adults (age=23.2±3.1 years; 14 women/17 men). Data indicated that wearing a cloth face mask led to a significant reduction in exercise time (−01:39±01:19 min/sec, p<0.001), maximal oxygen consumption (VO2max) (−818±552 mL/min, p<0.001), minute ventilation (−45.2±20.3 L/min), maximal heart rate (−8.4±17.0 beats per minute, p<0.01) and increased dyspnoea (1.7±2.9, p<0.001). Our data also suggest that differences in SpO2 and rating of perceived exertion existed between the different stages of the CPET as participant’s exercise intensity increased. No significant differences were found between conditions after the 7-minute recovery period.ConclusionCloth face masks led to a 14% reduction in exercise time and 29% decrease in VO2max, attributed to perceived discomfort associated with mask-wearing. Compared with no mask, participants reported feeling increasingly short of breath and claustrophobic at higher exercise intensities while wearing a cloth face mask. Coaches, trainers and athletes should consider modifying the frequency, intensity, time and type of exercise when wearing a cloth face mask.


Sign in / Sign up

Export Citation Format

Share Document