FUZZY-PID CONTROLLER IN THE METHOD PULSE WIDTH MODULATION CONVERTER ACTIVE POWER FILTER

2018 ◽  
Vol 28 (104) ◽  
pp. 8-15
Author(s):  
R. V. Vlasenko, ◽  
◽  
S. S. Bondarenko
2018 ◽  
Vol 1 (1) ◽  
pp. 54-66
Author(s):  
Rakan Khalil Antar ◽  
Basil Mohammed Saied ◽  
Rafid Ahmed Khalil

A new control strategy for active power filters is proposed, modeled and implemented in order to improve the power quality of a line commutated converter High voltage DC link. The ability of reactive power and harmonics reductions are generally met by using passive and active power filters. In this paper, modified active power filter with a modified harmonics pulse width modulation algorithm is used to minimize the source harmonics and force the AC supply current to be in the same phase with AC voltage source at both sending and receiving sides of a line commutated converter high voltage DC link. Therefore, it is considered as power factor corrector and harmonics eliminator with random variations in the load current. The modified harmonics pulse width modulation algorithm is applicable for active power filter based on a three-phase five-level and seven-level cascaded H-bridge voltage source inverter. Simulation results show that the suggested modified multilevel active power filters improve total harmonics distortion of both voltage and current with almost unity effective power factor at both AC sides of high voltage DC link. Therefore, modified active power filter is an effective tool for power quality improvement and preferable for line commutated converter high voltage DC link at different load conditions.


2014 ◽  
Vol 556-562 ◽  
pp. 3585-3589
Author(s):  
Meng Qiong Wang ◽  
Chun Yu Xu

In view of the shortages time lag existing in traditional digital low-pass filter in Active Power Filter (Active Power Filter, APF), this paper proposes to adopt slipped-window integrator to realize low-pass filter in harmonic current detection.The current tracking control uses Space Vector Pulse Width Modulation method. Meanwhile, the repetitive predictor is applied so as to improve the real-time performance of the compensation current tracking control. Built a three-phase shunt active power filter simulation model in Matlab/Simulink environment and take experiment under the low pressure condition. The results show that slipped-window integrator and deadbeat current mothod can acquire good dynamic response performance as well as high precision.


2018 ◽  
Vol 28 (02) ◽  
pp. 1950035 ◽  
Author(s):  
Jitendra Tandekar ◽  
Amit Ojha ◽  
Shailendra Jain

This paper presents an investigation on mitigation of current harmonics, using Cascaded H-bridge Multilevel Converter (CHB-MLC)-based Shunt Active Power Filter (SAPF). Development and analysis of SAPF for harmonic compensation in distribution network for power quality improvement has been discussed. In the proposed work, transformer-less CHB MLC is used which reduces weight and cost of the system. Moreover, a novel controller based on average power method is adopted for generation of compensation active filter current. In order to generate switching signals, multi-carrier Alternate Phase Opposition Disposition (APOD) — Pulse Width Modulation (PWM) schemes are used. The proposed CHB-MLC SAPF reduces the source current THD below 5%. The results are simulated in MATLAB/Simulink and demonstrate the effective mitigation of current harmonics with APOD-PWM schemes. Opal-RT OP4500 real-time digital simulator is used to validate the proposed scheme under different steady state and transient conditions.