scholarly journals Office High Rise Building- Fire Protection and Life Safety Analysis

2016 ◽  
Author(s):  
Fabio Renato Zocal Mazza
MODUL ◽  
2019 ◽  
Vol 19 (1) ◽  
pp. 50
Author(s):  
Yemima Sahmura Vividia ◽  
Bangun IR Harsritanto

Vertical occupancy, especially apartments, began to live the face of the city. Not without reason, housing needs continue to increase sharply as the availability of vacant land is increasingly limited. Occupying an apartment becomes a trend and lifestyle for young people. The reason boils down to productivity. The construction of apartments is usually built close to various activity centers, both business, commercial, education, health to entertainment. The improvement of building construction is not supported by the availability of land that is increasingly limited, especially in the city of Jarakta, making the construction of high-rise buildings anticipate this. The construction of multi-story buildings also increases the risk of fire. In 2018, according to him, there were at least 1,078 recorded disaster events throughout 2018. Head of the Jakarta Fire and Rescue Management Agency, Subedjo, said that out of a total of 897 buildings or tall buildings in Jakarta, 280 tall buildings had not yet accomplished the fire protection system (Dinas, 2018).Therefore, this research needs to be done to evaluate the lifesaving facilities and infrastructure in the building. The application of fire safety in buildings can be evaluated regarding to NFPA 101 (2013). Based on NFPA 101A: Guide on Alternative Approaches for Life Safety (2013), there are 12 elements of safety and Regulation of the Minister of Public Works No. 26 / PRT / M / 2008 concerning Technical Requirements of Fire Protection Systems in Building Buildings. The building that became the object of research is one of the buildings in the area of Jakarta mentioned building X and building Y. The variables that are the focus of the research are fire stairs, fire doors, and access roads. Based on the results of the study, the level of reliability of the means of saving lives against fire hazards in building X is equal to 58% and in building Y is 65%.


2013 ◽  
Vol 433-435 ◽  
pp. 2267-2276 ◽  
Author(s):  
Huai Chao Yan ◽  
Lin Jie Li ◽  
Jun Ge Huang

With the high-rise building fire accidents have increased every year, the appearance of home fire evacuation cabin has a very important significance.At first,We introduced the development status of domestic and international mine refuge Chamber and two mine refuge Chamber products which was used commonly,and analysed their merit and shortcoming,where we could get the inspiration;Then we focused on the present situation of the household refuge compartment and analysis of its shortcomings and the main problems need to be solved;Finally we put forward the design concept of the household fire refuge cabin .


1992 ◽  
Vol 11 (1) ◽  
pp. 19-23
Author(s):  
Belden Menkus

2014 ◽  
Vol 614 ◽  
pp. 605-609
Author(s):  
Jin Feng Wang ◽  
Ye Liu ◽  
Xue Qi Zhai

Firstly, this paper analyzed the factors affecting high-rise building fire safety in terms of the aspects of staff awareness, high-rise building fire design, fire-fighting facilities, daily management, and technology and so on. Secondly, on this basis, I determined the flow graph model and variables, and constructed high-rise building fire safety simulation model. Finally, a high-rise building was used to verify the applicability of the model. The findings have developed a clear direction in order to strengthen the management and formulation of high-rise building fire safety.


2012 ◽  
Vol 174-177 ◽  
pp. 3023-3026
Author(s):  
Jian Min Liu

Elevators are increasingly widely used in high-rise buildings. Because of its fast running, elevators, with great potential value and social requirements, are now days becoming very important traffic tools in high-rise buildings. However, it is an urgent problem to evacuate safely by using elevators during high-rise building fire accidents. This paper elaborates the necessity of elevator evacuation, analyzed the problem of evacuation by general passenger elevators. Some useful measures are put forward, such as fire prevention, smoke-proof, water-proof and emergency power supply for elevator evacuation during high-rise building fires. It is of great importance for us to utilize these measures for the evacuation by elevators during high-rise building fire accidents.