Sustainability of Cardiac Imaging

2011 ◽  
Vol 7 (3) ◽  
pp. 167 ◽  
Author(s):  
Eugenio Picano ◽  

Medical imaging is the largest controllable source of radiation exposure in the population of industrialised countries – totalling around 150 chest X-rays per head per year. Of these exposures, one half comes from cardiovascular testing (cardio-computed tomography [CT], nuclear cardiology and interventional cardiology). The high level of radiation exposure provides immense benefits when appropriate, but may result in an increased incidence of radiation-induced cancer in the not-too-distant future. Current estimates suggest that about five to 10 % of all cancers may be due to medical radiation exposure. Of every three examinations, one is inappropriately prescribed (lack of justification) and another is performed with inappropriately high radiation doses (lack of optimisation). Cardiologists are often unaware of the radiological dose of the examination they prescribe or practice, but they should make every effort so that “each patient should get the right imaging exam, at the right time, with the right radiation dose”, as suggested by US Food and Drug Administration (FDA) in the 2010 initiative to reduce unnecessary radiation exposure from medical imaging. This is best obtained through a systematic implementation of the ‘3A’s strategy’ proposed by the International Atomic Energy Agency in 2011: audit (of true delivered dose); appropriateness (since at least one-third of examinations are inappropriate); awareness (since the knowledge of doses and risks is largely suboptimal in doctors and patients). A good cardiologist cannot be scared of radiation, but must always remain aware of the risks.

2019 ◽  
Vol 188 (2) ◽  
pp. 199-204
Author(s):  
Y Lahfi ◽  
A Ismail

Abstract The aim of the present study was to evaluate the radiation exposure around the patient table as relative to the cardiologist position dose value. The dose rates at eight points presuming staff positions were measured for PA, LAO 30° and RAO 30° radiographic projections, and then normalized to the cardiologist’s position dose-rate value. The results show that in PA and RAO 30° projections, the normalized dose rate was higher by 9–22% at the right side of the table at a distance of 50 cm, while it was higher up to 31% at the left side for the same measured points in the LAO 30°. The differences of normalized dose rates for the both table sides were lower and decreased at farther positions. The obtained results correspond to the recommendations of staff radiation protection in Cath-labs with regards to X-ray tube and detector positions.


2021 ◽  
Vol 1 (1) ◽  
pp. 22-25
Author(s):  
Heryani Heryani ◽  
Nurul Firdausi Nuzula ◽  
Ari Dwi Reskianto ◽  
Ryan Wahyu Widhianto

Analysis of Distributed Radiation Exposure in The Covid-19 Isolation Room in Kraton Re¬gional Hospital, Pekalongan Regency. Since Covid-19 was declared a world pandemic by WHO, isolation rooms have become a place that is often used to deal with pandemics. Radiological examinations or X-rays are used as a supporting examination in the diagnosis of Covid-19. So it is necessary to adjust the Covid protocol in the examination so that there is no transmission of the virus and the effects of unnecessary radiation. Isolation rooms used for radiological examinations of Covid-19 patients need to be reviewed for safety to comply with procedures. The purpose of this paper is to analyze the scattering radiation exposure in the Seruni isolation room of RSUD Kraton, Pekalongan Regency. The data in this paper were taken by measuring the amount of scatter radiation exposure in room B of the isolation room Seruni RSUD Kraton Pekalongan Regency, on February 16, 2021. This measurement was carried out with a water phantom as object with the highest exposure factor for thorax examination, namely 70 kV and 16 mAs and carried out at several points around the water phantom object with a distance of 2 meters from the source. The measurement results of scattered radiation exposure are then compared with the Dose Limit Value (NBD) for the general public of 1 mSv in one year. Analysis of the measure¬ment of scatter radiation exposure in the Seruni isolation room at Kraton Hospital, Pekalongan Regency, still experienced leaks and the exposure value exceeded tolerance. The measurement results in the hallway of the Seruni room are 676 Sv/h, in addition to the radiographer (2 meters on the left side of the phantom) it is 627.12 Sv/h, at a distance of 2 meters the right side of the phantom is 287.04 Sv/h, and a distance of 2 meters in front of the hall phantom of 676 Sv/h. The follow-up that needs to be done to optimize radiation protection is to install at least 3 scattering radiation shields.


2010 ◽  
Vol 63 (7-8) ◽  
pp. 565-569
Author(s):  
Milan Radovic ◽  
Lidija Ristic ◽  
Ivana Stankovic ◽  
Dejan Petrovic

Introduction. Patients with congenital cyanotic heart defects and the left-to-right shunt are at a three times higher risk of getting tuberculosis than acyanotic ones. No TB cases have been recorded in adult patients with the right-to-left shunt having cyanosis since their birth. Case report. A 34-year-old man was referred to our Clinic with the discomforts such as chronic cough, hemoptysis and insomnia. At the admission he was pale, cyanotic, with a partial manifest respiratory insufficiency and characteristic TB pulmonary lesions detected by x-rays and tomography. After the sputum positive TB recidivism had been diagnosed, the antituberculotics treatment was introduced resulting in the successful smear and culture conversion and radiological regression of pulmonary lesions, but associated with non-explicable deterioration of cyanosis and chronic respiratory insufficiency until Doppler-echocardiographic examination verified the presence of tetralogy of Fallot. Conclusion. Congenital cyanotic heart defects are extremely rare in adults. Nevertheless, it is necessary to maintain a very high level of clinical suspicion regarding TB activation even in the cases of defects with the right-to-left shunt.


Author(s):  
Christoph I. Lee

This chapter, found in the radiation exposure from medical imaging section of the book, provides a succinct synopsis of a key study examining low-dose ionizing radiation exposure and radiation-induced cancer risks. This summary outlines the study methodology and design, major results, limitations and criticisms, related studies and additional information, and clinical implications. The study reported that a substantial proportion of the nonelderly US population is exposed to medium to very high annual effective doses from medical imaging procedures. Strategies ensuring the appropriate use of medical imaging associated with ionizing radiation should be developed and adopted widely. In addition to outlining the most salient features of the study, a clinical vignette is included in order to provide relevant clinical context.


Mastology ◽  
2020 ◽  
Vol 30 (Suppl 1) ◽  
Author(s):  
Jackson Roberto de Moura

M.C.V., aged 54, born in Presidente Bernardes, Minas Gerais, was admitted on 09/10/2018 with a palpable alteration in the right breast, having a 15mm heterogeneous lobed nodule at the junction of the upper quadrant of the right breast (BI-RADS 5) with mammography having focal asymmetry in the same position (BI-RADS 0), being submitted to core-biopsy by ultrasound with resulting Infiltrating Ductal Carcinoma – Grade 3. Immunohistochemical pattern reveals positivity of the estrogen and progesterone hormone receptors, C-ERB B2 with a score of +2 and Ki67‒positive by 20%. Negative Fish test. She refused treatment, returning to the service on 14/08/2019 with normal physical examination, an 8 mm ultrasound lesion at the junction of the upper quadrants of the right breast (BI-RADS 6) and regression in mammography of focal asymmetry. Staging study performed with chest X-rays, total abdomen ultrasound and normal bone scintigraphy. Laboratory study was normal, except for the high level of total IgE in 4,290. She underwent segmental and sentinel lymph node resection in the right breast on 17/08/2019 at Hospital São Vicente de Paula, Ubá, Minas Gerais, with histological result, infiltrating lobular carcinoma, 9 mm in size, free margins and study of the negative sentinel lymph node. Radiotherapy and use of Tamoxifen 20mg for 5 years were indicated. It was possible to conclude that there is something different, possibly associated with the high level of IgE, which we continue to study to further understand.


2019 ◽  
Vol 65 (1) ◽  
pp. 27-41
Author(s):  
Yelena Artamonova

Lung cancer is the leading cause of mortality from malignant tumors all over the world. Since most patients at the time of diagnosis already have stage III-IV of the disease, the search for new effective treatment strategies for advanced NSCLC is the most important problem of modern oncology. The results of the study of the anti-PD1 monoclonal antibody pembrolizumab were a real breakthrough in the treatment of NSCLC. In the KEYN0TE-001 study, the expression of PD-L1 on tumor cells was validated as a predictive biomarker of the drug's efficiency. Pembrolizumab demonstrated the possibility of achieving long-term objective responses, and a 4-year 0S with all histological types in the subgroup of pre-treated patients with PD-L1 expression> 50% was 24.8% and 15.6% in the PD-L1> 1% group. In a phase 2/3 randomized study KEYN0TE-10 in the 2nd line treatment of NSCLC with PD-L1 expression > 1% pembrolizumab significantly increased life expectancy compared to docetaxel and confirmed the possibility of longterm duration of objective responses, even after cessation of treatment. Then the focus of research shifted to the 1st line of treatment. About 30% of patients with NSCLC have a high level of PD-L1 expression on tumor cells and demonstrate the most impressive response to pembrolizumab therapy. A randomized phase 3 study KEYN0TE-024 compared the effectiveness of pembrolizumab monotherapy with a standard platinum combination in patients with advanced NSCLC with a high level of PD-L1 expression without EGFR mutations or ALK translocation. Compared with the platinum doublet the administration of pembrolizumab significantly increased all estimated parameters, including the median of progression-free survival (mPFS was 10.3 months versus 6 months; HR = 0.50; 95% CI 0.37-0.68, p < 0.001), the objective response rate (ORR 44.8% versus 27.8%), duration of response (in the pembrolizumab arm the median was not reached, in the chemotherapy (CT) group - 6.3 months). Despite the approved crossover, the use of pembrolizumab in the 1st line of treatment more than doubled the life expectancy of NSCLC patients with high PD-L1 expression as compared to CT: the median overall survival (OS) was 30.0 months versus 14.2 months (HR = 0.63, p = 0.002), 1-year OS 70.3% versus 54.8%; 2-year OS - 51.5% versus 34.5%. The remaining population to study were untreated patients with any level of PD-L1 expression. A randomized phase 3 study KEYNOTE-189 evaluated the effectiveness of adding pembrolizumab to the platinum combination in the 1st line treatment of non-squamous NSCLC without EGFR and ALK mutations with any PD-L1 expression. The addition of pembrolizumab to the standard 1st line CT significantly increased all estimated efficacy indicators including OS, PFS and ORR. After a median follow-up of 10.5 months the median OS in the pembrolizumab combination group was not reached and in CT group was 11.3 months. The estimated 12-months survival was 69.2% and 49.4% respectively (HR = 0.49; 95% CI 0.38-0,64; p <0.001). The median PFS was 8.8 months versus 4.9 months, alive 1 year without progression 34.1% and 17.3% of patients respectively (HR = 0.52; p <0.001). The ORR in the group with pembrolizumab reached 47.6% versus 18.9% in CT group, moreover the tumor regressions were much longer. Finally a randomized 3-phase study KEYN0TE-407 evaluated the effectiveness of adding pembrolizumab to 1st-line CT of NSCLC with squamous histology with any PD-L1 expression. As the first analysis showed, the addition of permboli-zumab significantly increased OS of patients with squamous NSCLC, median OS 15.9 months versus 11.3 months in the groups of pembrolizumab + CT and placebo + CT respectively (HR = 0.64; 95% CI 0,49-0.95; p = 0.0006), median PFS 6.4 months and 4.8 months respectively (HR = 0.56; 95% CI 0.450.70; p <0, 0001) and OrR 57.9% versus 38.4%, the median response duration 7.7 months versus 4.8 months. Thus, the convincing advantages of using pembrolizumab in 1st line therapy were demonstrated in 3 randomized phase 3 studies: in monotherapy of NSCLC of any histological subtype with high PD-L1 expression, and in combination with CT in squamous and non-squamous hystologies regardless of the level of PD-L1 expression.


2021 ◽  
Vol 193 (1) ◽  
pp. 43-54
Author(s):  
Yasuda Mitsuyoshi ◽  
Funada Tomoya ◽  
Sato Hisaya ◽  
Kato Kyoichi

Abstract As chest x rays involve risks of patients falling, radiologic technologists (technologists) commonly assist patients, and as the assistance takes place near the patients, the eye lenses of the technologists are exposed to radiation. The recommendations of the International Commission on Radiological Protection suggest that the risk of developing cataracts due to lens exposure is high, and this makes it necessary to reduce and minimize the exposure. The present study investigated the positions of technologists assisting patients that will minimize exposure of the eye lens to radiation. The results showed that it is possible to reduce the exposure by assisting from the following positions: 50% at the sides rather than diagonally behind, 10% at the right side of the patient rather than the left and 40% at 250 mm away from the patient. The maximum reduction with radiation protection glasses was 54% with 0.07 mmPb and 72% with 0.88 mmPb.


2021 ◽  
Vol 11 (12) ◽  
pp. 5453
Author(s):  
Hwa-Seob Song ◽  
Jae-Hong Woo ◽  
Jong-Yun Won ◽  
Byung-Ju Yi

Conventional vascular intervention (VI) procedures are typically performed manually under exposure to X-rays, whereby several problems are presented that need to be addressed owing to the patients and doctors being exposed to large amounts of radiation. In such cases, employing radiation protection units is not a long-term solution to avoid physical damage. Therefore, to overcome these issues, we propose a robotic VI system in this study. Moreover, we compare the extent of radiation exposure in the case of the conventional manual VI procedure with that in the case of the robotic procedure. The radiation exposure is then analyzed from the perspective of the doctor. Subsequently, the results of usability tests for two proposed master devices are presented in terms of the NASA task load index (NASA-TLX) and the system usability scale (SUS) score. To verify the effectiveness of the robotic VI system, animal experiments are conducted using a pig model. Among the two types of master devices tested with the proposed robotic VI system, the ergonomically designed 2-degree-of-freedom master device is found to be more effective than the joystick-type device in terms of the usability test scores. Hence, the proposed robotic VI procedure is shown to be advantageous in terms of reducing radiation exposure and improving usability.


Author(s):  
Aida Mekhoukhe ◽  
Nacer Mohellebi ◽  
Tayeb Mohellebi ◽  
Leila Deflaoui-Abdelfettah ◽  
Sonia Medouni-Adrar ◽  
...  

OBJECTIVE: the present work proposed to extract Locust Bean Gum (LBG) from Algerian carob fruits, evaluate physicochemical and rheological properties (solubility). It aimed also to develop different formulations of strawberry jams with a mixture of LBG and pectin in order to obtain a product with a high sensory acceptance. METHODS: the physicochemical characteristics of LBG were assessed. The impact of temperature on solubility was also studied. The physical and the sensory profile and acceptance of five Jams were evaluated. RESULTS: composition results revealed that LBG presented a high level of carbohydrate but low concentrations of fat and ash. The LBG was partially cold-water-soluble (∼62% at 25°C) and needed heating to reach a higher solubility value (∼89% at 80 °C). Overall, the sensorial acceptances decreased in jams J3 which was formulated with 100% pectin and commercial one (J5). The external preference map explained that most consumers were located to the right side of the map providing evidence that most samples appreciated were J4 and J2 (rate of 80–100%). CONCLUSION: In this investigation, the LBG was used successfully in the strawberry jam’s formulation.


Sign in / Sign up

Export Citation Format

Share Document