Development and validation of high-performance liquid chromatography method for the simultaneous monitoring of pantoprazole sodium sesquihydrate and domperidone maleate in plasma and its application to pharmacokinetic study

2020 ◽  
Vol 32 (3) ◽  
pp. 157-165
Author(s):  
Ghulam Abbas ◽  
Malik Saadullah ◽  
Akhtar Rasul ◽  
Shahid Shah ◽  
Sajid Mehmood Khan ◽  
...  

A sensitive, inexpensive high-performance liquid chromatography–ultraviolet detection (HPLC–UV) method has been developed and validated for the simultaneous monitoring of pantoprazole sodium sesquihydrate (PSS) and domperidone maleate (DM) in rabbit plasma on a C18 column with UV detection at 285 nm. Box–Behnken design was used with 3 independent variables, namely, flow rate (X1), mobile phase composition (X2), and phosphate buffer pH (X3), which were used to design mathematical models. Response surface design was applied to optimize the dependent variables, i.e., retention time (Y1 and Y2) and percentage recoveries (Y3 and Y4) of PSS and DM. The method was sensitive and reproducible over 1.562 to 25 μg/mL. The effect of the quadratic outcome of flow rate, mobile phase composition, and buffer pH on retention time (p ˂ 0.001) and percentage recoveries of PSS and DM (p = 0.0016) were significant. The regression values obtained from analytical curve of PSS and DM were 0.999 and 0.9994, respectively. The percentage recoveries of PSS and DM were ranged from 94.5 to 100.41% and 94.77 to 100.31%, respectively. The developed method was applied for studying the pharmacokinetics of PSS and DM. The Cmax of test and reference formulations were 48.06 ± 0.347 μg/mL and 46.31 ± 0.398 μg/mL for PSS, and 15.11 ± 1.608 μg/mL and 12.06 ± 1.234 μg/mL for DM, respectively.

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (07) ◽  
pp. 14-21
Author(s):  
S. Sahu ◽  
◽  
R.M Singh ◽  
S.C. Mathur ◽  
D. K Sharma ◽  
...  

A simple, fast, precise and accurate ultra high performance liquid chromatography method was developed for degradation study of eletriptan hydrobromide (EH) under exaggerated conditions. An Inertsil ODS C18 (250 x 4.6 mm, 5µm) column in isocratic mode was used with mobile phase comprising of water, methanol and trifluoroacetic acid mixed in the ratio 55:45:0.1 % V/V/V, maintained at pH 3.5. The flow rate was set at 0.4 mL per minute with UV detection at 225 nm. The retention time of EH was found to be 3.7 minutes. Linearity for EH was found in the range of 3.5- 200 µg per mL and percentage recoveries were obtained in the range of 100.2 % to 100.6 %. The method was capable of resolving all degradants and principle component in sample. The proposed method is accurate, precise, selective, reproducible, and rapid for detection of degradation of eletriptan hydrobromide.


2018 ◽  
Vol 10 (1) ◽  
pp. 133
Author(s):  
Dwi Karina Natalia ◽  
Harmita . ◽  
Taufiq Indra Rukmana

Objective: This study aimed to develop a selective analytical method for assessing disodium 5′-guanylate and disodium 5′-inosinate levels in flavorenhancers.Methods: The levels were assessed using high-performance liquid chromatography (HPLC) with a photodiode array detector (PDA) (wavelength=255 nm) and a SunFire® C18 column (250 mm × 4.6 mm × 5 μm). The mobile phase comprised a mixture of potassium phosphate buffer and anion pair reagent-hexane-1-sulfonic acid sodium salt - with a flow rate of 1.2 mL/min. The ion pair was used to generate a neutral equilibrium, whichresulted in increased retention of the analytes. Optimized analysis conditions were then validated regarding accuracy, precision, linearity, selectivity,and the limits of detection and quantification.Results: The average levels of disodium 5′-inosinate in the six analyzed samples were 0.24±1.46, 0.21±2.69, 0.58±3.26, 0.21±0.84, 0.22±3.59, and0.47±2.21%, respectively. Regarding disodium 5′-guanylate, the average levels were 0.15±2.85, 0.15±0.12, 0.41±3.80, 0.16±1.72, 0.27±1.18, and0.34±1.83, respectively.Conclusion: The optimal conditions for analyzing disodium 5′-guanylate and disodium 5′-inosinateusing HPLC with a PDA and SunFire C18 columnwere λ=255 nm, a mobile phase of potassium phosphate buffer and sodium hexane sulfonate, and a flow rate of 1.2 mL/min. For disodium 5′-inosinate,its average levels in samples A–F were 0.24±1.46, 0.21±2.69, 0.58±3.26, 0.21±0.84, 0.22±3.59, and 0.47±2.21%, respectively. Meanwhile, the averagelevels of disodium 5′-guanylate in the samples were 0.15±2.85, 0.15±0.12, 0.41±3.80, 0.16±1.72, 0.27±1.18, and 0.34±1.83%, respectively.


Sign in / Sign up

Export Citation Format

Share Document