scholarly journals ZnO Microcrystals for Light Emitting Diode and Photovoltaic Applications with Integration on Flexible Substrates

2009 ◽  
Vol 1192 ◽  
Author(s):  
Jesse J Cole ◽  
Heiko Jacobs

AbstractWe report a new integration approach to produce arrays of ZnO microcrystals for optoelectronic and photovoltaic applications. Demonstrated applications are n-ZnO/p-GaN heterojunction LEDs and photovoltaic cells. The integration process uses an oxygen plasma treatment in combination with a photoresist pattern on Magnesium doped GaN substrates to define a narrow sub-100nm width nucleation region. ZnO is synthesized in the defined areas by a hydrothermal technique using zinc acetate and hexamethylenetetramine precursors. Nucleation is followed by lateral epitaxial overgrowth producing single crystal disks of ZnO. The process provides control over the dimension and location of the ZnO crystals. The quality of the patterned ZnO is high; the commonly observed defect related emission in the electroluminescence spectra is suppressed and a single near-band-edge UV peak is observed. Transfer printing of the ZnO microcrystals onto a flexible substrate is also demonstrated in the context of transparent flexible electronics.

2019 ◽  
Vol 27 (5) ◽  
pp. 6832
Author(s):  
J. B. Park ◽  
W. S. Choi ◽  
T. H. Chung ◽  
S. H. Lee ◽  
M. K. Kwak ◽  
...  

Plants ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 960
Author(s):  
Jenny Manuela Tabbert ◽  
Hartwig Schulz ◽  
Andrea Krähmer

A light-emitting diode (LED) system covering plant-receptive wavebands from ultraviolet to far-red radiation (360 to 760 nm, “white” light spectrum) was investigated for greenhouse productions of Thymus vulgaris L. Biomass yields and amounts of terpenoids were examined, and the lights’ productivity and electrical efficiency were determined. All results were compared to two conventionally used light fixture types (high-pressure sodium lamps (HPS) and fluorescent lights (FL)) under naturally low irradiation conditions during fall and winter in Berlin, Germany. Under LED, development of Thymus vulgaris L. was highly accelerated resulting in distinct fresh yield increases per square meter by 43% and 82.4% compared to HPS and FL, respectively. Dry yields per square meter also increased by 43.1% and 88.6% under LED compared to the HPS and FL lighting systems. While composition of terpenoids remained unaffected, their quantity per gram of leaf dry matter significantly increased under LED and HPS as compared to FL. Further, the power consumption calculations revealed energy savings of 31.3% and 20.1% for LED and FL, respectively, compared to HPS. In conclusion, the implementation of a broad-spectrum LED system has tremendous potential for increasing quantity and quality of Thymus vulgaris L. during naturally insufficient light conditions while significantly reducing energy consumption.


MRS Advances ◽  
2016 ◽  
Vol 1 (45) ◽  
pp. 3083-3088 ◽  
Author(s):  
Sujoy Kumar Ghosh ◽  
Dipankar Mandal

ABSTRACTA ferroelectric nanogenerator without any electric poling treatment has been realized by incorporation of ytterbium (Yb) salt incorporated porous PVDF composite film. The composite film compose of electroactive β- and γ-phases, demonstrates higher dielectric and ferroelectric polarization responses than pure PVDF film. The 3 V of open circuit voltage with 0.47 µW/cm2 power density was generated by the nanogenerator upon single finger touch. It can also operate capacitor and light emitting diode without any subsidiary batteries.


Endoscopy ◽  
2016 ◽  
Vol 48 (10) ◽  
pp. 934-938 ◽  
Author(s):  
Sho Sasaki ◽  
Jun Nishikawa ◽  
Hideo Yanai ◽  
Munetaka Nakamura ◽  
Junichi Nishimura ◽  
...  

2018 ◽  
Vol 2018 (1) ◽  
pp. 000665-000671
Author(s):  
Jianbiao Pan ◽  
Malcolm Keif ◽  
Joshua Ledgerwood ◽  
Xiaoying Rong ◽  
Xuan Wang

Abstract The lightweight and bendable features of printed flexible electronics are increasingly attractive. Currently stretchable silver inks are formulated for wide traces, typically larger than 2 mm. To attach ultra-thin silicon chips that have fine pitch onto printed organic substrate, it is necessary to print fine trace width/space that matches the pitch of the chips, which may be less than 200 microns. This paper presents the development and optimization of the screen printing process for printing stretchable silver ink onto stretchable thermoplastic polyurethane (TPU) substrate. A test vehicle was designed including 50 μm/5 mm (line width/line length) to 350 μm/35 mm lines (at 4 biases). The stretchable ink selected was DuPont PE 873 and Dupont's PE 5025 ink (non-stretchable conductive flake silver) was used as a “control” to baseline the printing process. The substrate used was Bemis TPU ST604. The experiment was done on a DEK Horizon 03i printer. A DEK squeegee 200 (Blue) and a DEK 265 flood bar (200 mm) were used. A 2-level factorial design with three replicates was selected to investigate the effect of process parameters on the quality of prints. The quality of the prints is characterized by 1) resistance of traces, 2) sheet resistance, 3) z-axis height, and 4) trace width/spacing. We observed significant noise in the z-axis printed silver ink height measured by profilometry and concluded z-axis height is not a good response variable for characterizing screen printing stretchable silver ink onto TPU substrate, mainly due to high roughness of the TPU substrate. We proposed calculated sheet resistance based on the measured resistance value, trace width, and trace length, which can replace trace height measurements on rough profile substrates. We found that squeegee pressure and emulsion thickness have statistically significant effects on calculated sheet resistance of print traces while print speed does not have statistically significant effects. In our experiment setting levels, the lower the squeegee pressure, the lower the calculated sheet resistance that is achieved. The emulsion with higher emulsion over mesh (EOM) is better than the emulsion with lower EOM since it can achieve lower sheet resistance. After optimizing the screen printing process, we were able to print 100 μm (4 mils) trace width and spacing with high consistency.


2015 ◽  
Vol 15 (10) ◽  
pp. 8144-8148 ◽  
Author(s):  
Jae Woo Lee ◽  
Ho Won Lee ◽  
Song Eun Lee ◽  
Hyung Jin Yang ◽  
Sung Kyu Lee ◽  
...  

In this paper, we fabricated tri-metal layered thin film semitransparent electrodes consisting of a thin conductive metal layer, sandwiched between two nickel layers. An equal red phosphorescent organic light-emitting diode (PHOLED) structure was deposited on the anodes of indium tin oxide (ITO) and three types of tri-metal layers (Ni/Al/Ni, Ni/Cu/Ni, and Ni/Ag/Ni, thickness of 3/7/3 nm in common) on a glass substrate. The optical and electrical performances of the device using Ni/Ag/Ni were improved more than the performances of the other devices due to the micro-cavity effect in accordance with the various electrode characteristics. Moreover, we fabricated the same red PHOLED structures on a flexible substrate, as a consequence, showed competitive emission characteristics compared to the devices fabricated on a glass substrate. Therefore, this study could succeed to additional research on flexible display panel and light-emitting devices with ITO-free electrodes.


Author(s):  
K. Rae ◽  
E. Y. Xie ◽  
A. J. Trindade ◽  
B. Guilhabert ◽  
R. Ferreira ◽  
...  

2013 ◽  
Vol 378 ◽  
pp. 440-443
Author(s):  
Chiu Jung Yang ◽  
Chien Sheng Huang ◽  
Chih Wei Chen ◽  
Po Wen Chen

Thepaperis discussedin coloruniformity study.The experiment divided into two steps in this study,first is modules design and simulation. Second is fabrication and measurement.After measure the LEDs property, calculating the ratio of each colored LEDs by using Grassmanns Law,modeling by Solidworks, and simulating the front study by optical software TracePro.Using four-color mixing with self-developed formula to avoid the present white light emitting diode patent, and the four-color grains are Red, Green, Blue and adding Y to modify the overall quality of the mixed light.The phosphorproduceSteabler-Wronsk hardly in the high temperatureas compared tofour-color mixing.Using four-color mixing to producehigher color rendering index than yellow phosphor.Series-parallel array of grain arrangement adopted to achieve the high demand for uniformity, while simplifying the design conditions by a certain current instead of the general mixed light-driven complex driver circuit,the completion of the mixing module using integrating sphere, light spectrum on the spectrophotometer, optical power, color coordinates values, such as mixing uniformity measurements.The chromaticity coordinates errors after complete results of the mixing module measurement and simulation can be controlled under (0.01x, 0.01y).


2016 ◽  
Vol 41 (3) ◽  
pp. E13 ◽  
Author(s):  
Sunil Manjila ◽  
Margherita Mencattelli ◽  
Benoit Rosa ◽  
Karl Price ◽  
Georgios Fagogenis ◽  
...  

OBJECTIVE Rigid endoscopes enable minimally invasive access to the ventricular system; however, the operative field is limited to the instrument tip, necessitating rotation of the entire instrument and causing consequent tissue compression while reaching around corners. Although flexible endoscopes offer tip steerability to address this limitation, they are more difficult to control and provide fewer and smaller working channels. A middle ground between these instruments—a rigid endoscope that possesses multiple instrument ports (for example, one at the tip and one on the side)—is proposed in this article, and a prototype device is evaluated in the context of a third ventricular colloid cyst resection combined with septostomy. METHODS A prototype neuroendoscope was designed and fabricated to include 2 optical ports, one located at the instrument tip and one located laterally. Each optical port includes its own complementary metal-oxide semiconductor (CMOS) chip camera, light-emitting diode (LED) illumination, and working channels. The tip port incorporates a clear silicone optical window that provides 2 additional features. First, for enhanced safety during tool insertion, instruments can be initially seen inside the window before they extend from the scope tip. Second, the compliant tip can be pressed against tissue to enable visualization even in a blood-filled field. These capabilities were tested in fresh porcine brains. The image quality of the multiport endoscope was evaluated using test targets positioned at clinically relevant distances from each imaging port, comparing it with those of clinical rigid and flexible neuroendoscopes. Human cadaver testing was used to demonstrate third ventricular colloid cyst phantom resection through the tip port and a septostomy performed through the lateral port. To extend its utility in the treatment of periventricular tumors using MR-guided laser therapy, the device was designed to be MR compatible. Its functionality and compatibility inside a 3-T clinical scanner were also tested in a brain from a freshly euthanized female pig. RESULTS Testing in porcine brains confirmed the multiport endoscope's ability to visualize tissue in a blood-filled field and to operate inside a 3-T MRI scanner. Cadaver testing confirmed the device's utility in operating through both of its ports and performing combined third ventricular colloid cyst resection and septostomy with an endoscope rotation of less than 5°. CONCLUSIONS The proposed design provides freedom in selecting both the number and orientation of imaging and instrument ports, which can be customized for each ventricular pathological entity. The lightweight, easily manipulated device can provide added steerability while reducing the potential for the serious brain distortion that happens with rigid endoscope navigation. This capability would be particularly valuable in treating hydrocephalus, both primary and secondary (due to tumors, cysts, and so forth). Magnetic resonance compatibility can aid in endoscope-assisted ventricular aqueductal plasty and stenting, the management of multiloculated complex hydrocephalus, and postinflammatory hydrocephalus in which scarring obscures the ventricular anatomy.


Author(s):  
Suzi Seroja Sarnin ◽  
Nur Jumaatul Hidayati Binti Mohammad ◽  
Nani Fadzlina Naim ◽  
Norsuzila Ya’acob ◽  
Azlina Idris ◽  
...  

<span>One of the key issues for those involved in farming and greenhouse is the use of pesticides. In a recent headline, there has been an epidemic of insect infestation that has destroyed 211 hectares of rice plants. These concerns have led to the discussion of possible over-use of pesticides that are not just killing dangerous pests, but also other animals that help combat the pest. In order to overcome the problem, a research was conducted by introducing a smart insect killer.  In this developing project, Pyroelectric (PIR) sensor will be using as a motion detector towards insects. This sensor plays a role to transmit the signal for action in taking care of the plant. The IR sensors will install around the plant, so that it has good range to detect any motion. As a result, suitable chemical spray will trigger to repel these insects. A light emitting diode as an indicator of functional to the system.  "Smart Insect Repeller" will work when certain pests are detected and this will reduce the use of poisons and the quality of the crop will be preserved due to the use of minimal poisons.</span>


Sign in / Sign up

Export Citation Format

Share Document