Mechanical vs. Pneumatic Model of Measuring Probe in Voltage Acupuncture Skin Mapping

2015 ◽  
Vol 8 (6) ◽  
pp. 434
Author(s):  
Marek Kukučka ◽  
Štefan Kozák ◽  
Andreas Weisze ◽  
Daniela Ďuračková ◽  
Viera Stopjaková ◽  
...  
Keyword(s):  
2020 ◽  
pp. 35-37
Author(s):  
Ya.L. Liberman ◽  
A.N. Mahiyanova ◽  
Gorbunova L.N.

The metrological scheme of the control head of a simplified design is presented, its kinematic accuracy is analyzed. It is shown, that the effectiveness of the use of the head of this design, i.e., the accuracy of control, when controlling tolerances, in the manufacture of the part depends on the choice of the length of the measuring probe. Keywords part, size, control, measuring probe, kinematic accuracy, metrological scheme. [email protected]


2019 ◽  
Vol 30 (14) ◽  
pp. 2135-2146 ◽  
Author(s):  
Weijie Li ◽  
Tiejun Liu ◽  
Shasha Gao ◽  
Mingzhang Luo ◽  
Jianjun Wang ◽  
...  

Corrosion of metallic structures widely existed in multiple industries, such as oil and gas, civil infrastructure, aerospace, mechanical, mining, and processing. Current available corrosion-monitoring methods are based on different sensing principles, which have their own advantages, and some drawbacks that may limit their application on some aspects. This article presents an electromechanical impedance-instrumented corrosion-measuring probe for corrosion monitoring. The proposed probe is fabricated by attaching a circular lead zirconate titanate patch onto a metal rod. Compared to other electromechanical impedance-based corrosion-monitoring methods, the probe is capable of isolating the influence of structural complexity, variations in loading and boundary conditions. Five probes were fabricated in the experimental study and three of them were subjected to accelerated corrosion tests to mimic the corrosion-induced mass loss damage. Results showed that the peak magnitude of the conductance signatures was reduced with the increase in corrosion amount. The variations in the conductance signatures were quantified by three statistical quantifying metrics, that is, root-mean-square deviation, mean absolute percentage deviation, and correlation coefficient deviation. All these metrics increase with the increase in corrosion amount, which can be used as an indicator of the corrosion process. This study proves that the proposed corrosion-measuring probe is effective in monitoring corrosion and shows promising application potential. This research also serves as a proof-of-concept study to demonstrate the capability of the electromechanical impedance technique in monitoring mass loss due to corrosion.


1993 ◽  
Author(s):  
Yong-Le Chen ◽  
Qing-Dong Min ◽  
Pan Fu ◽  
Hai-Yang Liao ◽  
Guo-Qing Jiang

Sign in / Sign up

Export Citation Format

Share Document