scholarly journals DRAIN AMYLASE ON THE FIRST POSTOPERATIVE DAY OF WHIPPLE SURGERY: WHAT VALUE IS THE BEST PREDICTOR FOR EARLY DRAIN REMOVAL?

Author(s):  
Enio Campos AMICO ◽  
Ítalo Medeiros de AZEVEDO ◽  
Marcos Vinicius de Lira FERNANDES ◽  
Mariane Albuquerque REIS ◽  
Samir Assi JOÃO

ABSTRACT Background: The value of drain amylase on the first postoperative day after pancreatic resections has been described as an efficient predictor of pancreatic fistula. In spite of this, the cut-off point below which the drains can be removed early remains controversial. Aim: Validate the use of the amylase on the 1st postoperative day in the correlation with pancreatic fistula and define the value at which early drain removal is safe. Method: Were included patients undergoing Whipple surgery in the period of 2007 to 2016. Group 1 enrolled the ones who did not develop fistula and those who developed biochemical fistula for less than seven days postoperatively and group 2 included patients who developed persistent biochemical fistula between seven and 21 days and those with grade B and C fistula. Results: Sixty-one patients were included, 41 comprised group 1 and 20 group 2. The incidence of abdominal collections, need for reoperation and time of hospitalization were for group 1 and 2, respectively: 17.1%, 17.1% and 9.5 days, and 65%, 40% and 21.1 days. The median of the amylase from the drain at 1st postoperative day was in group 1 and 2, respectively: 175 U/l and 3172.5 U/l (p=0.001). Using a cut-off of 180 to predict the group to which the patient would belong there was obtained sensitivity, specificity, positive predictive value and negative predictive value of 100%, 48.8%, 50% and 100% respectively. Conclusion: It was validated the cut-off value of 180 U/l as appropriate to early drain removal.

2008 ◽  
Vol 66 (4) ◽  
pp. 785-789 ◽  
Author(s):  
Marcos Christiano Lange ◽  
Viviane Flumignan Zétola ◽  
Admar Moraes de Souza ◽  
Élcio Juliato Piovesan ◽  
Juliano André Muzzio ◽  
...  

Right-to-left shunt (RLS) can be identified by contrast-enhanced transcranial Doppler (cTCD) in patent foramen ovale (PFO) patients. AIM: To evaluate cTCD for PFO screening comparing it to cTEE. METHOD: 45 previous cTCD performed for PFO diagnosis and correlated its findings with cTEE. Patients were submitted to a cTCD standardized technique and were divided in two groups according to RLS: Group 1, patients with a positive RLS and Group 2 when RLS was negative. RESULTS: 29 (65%) patients were included in group 1 and 16 (35%) in group 2. PFO confirmation by cTEE was performed in 28 (62%) patients. cTCD had a 92.85% sensitivity, 82.35% specificity, 89.65% positive predictive value and 87.5% negative predictive value when compared to cTEE for PFO diagnosis. CONCLUSION: Standardized technique cTCD allows for RLS visualization in PFO patients with a good correlation with cTEE and can be used as a screening test before cTEE.


2020 ◽  
Vol 405 (7) ◽  
pp. 1039-1044
Author(s):  
S. Ferencz ◽  
Zs. Bíró ◽  
A. Vereczkei ◽  
D. Kelemen

Abstract Purpose Pancreatic fistula following pancreatic resections is still a relevant complication. The present work shows the efforts of a single institute to decrease this problem. Methods A total of 130 patients (63 men, 67 women) with a mean age of 60 (range: 23–81) years were operated on between January 2013 and March 2020. The most frequent type of pancreatic resection was a Whipple procedure with partial antrectomy. During all operations, an innovative method was used, namely a modification of the purse-string suture pancreatojejunostomy. Moreover, an early drain removal policy was applied, based on the drain amylase level on the first and subsequent postoperative days. Results Mean postoperative hospital stay was 13 days (range: 7–75). The overall morbidity rate was 43.8%; the clinically relevant (grade B/C) pancreatic fistula (CR-POPF) rate was 6.9%. Delayed gastric emptying (DGE) was observed in 4% of the patients. The ratio of operative mortality was 0.7%; the reoperation rate was 5.3%. Based on the drain amylase level on the first postoperative day, two groups could be established. In the first one, the drain was removed early, on the fourth day in average (range: 2–6). In the other group, the drain was left in situ protractedly or reinserted later on. Conclusion A single center’s experience proves that the refinement of the technique can improve the results of pancreatic surgery.


Ultrasound ◽  
2017 ◽  
Vol 25 (3) ◽  
pp. 150-155 ◽  
Author(s):  
Rustu Turkay ◽  
Ercan Inci ◽  
Mustafa Gurkan Yenice ◽  
Volkan Tugcu

Introduction Erectile dysfunction (ED) is a common health problem among males, and radiology has limited use in its diagnosis and treatment. Shear wave elastography (SWE) is a new sonographic technique. In this study, we examined the significance of SWE in the diagnosis of ED. Methods The study included a total number of 70 participants. The mean age of the participants was 54.14 ± 8.03 years (range: 39 and 71 years old). We composed two groups. Group 1 had 35 patients who presented to the urology clinic in our hospital complaining of ED, and had a score of 17 or lower from the International Index of Erectile Function (IIEF) questionnaire. Group 2 consisted of 35 healthy volunteers who did not have ED. SWE measurements were performed from corpus cavernosum penis in both groups, and the results were noted. Differences between the groups were evaluated statistically. Results The difference between the mean SWE measurements of two groups (Group 1: 20.94 ± 6.23 kPa and group 2: 24.63 ± 7.58 kPa) was found to be statistically significant ( p = 0.027; p < 0.05). For a cut-off value of 17.1 kPa, the SWE method has specificity, sensitivity, positive predictive value, and negative predictive value regarding diagnosis of ED as 94.29%, 34.29%, 85.71%, and 58.93%, respectively. The mean age of the groups did not show a statistically significant difference ( p = 0.287; p > 0.05). Conclusions Due to its high specificity and positive predictive value, SWE can offer useful data in the radiologic evaluation of ED cases.


2004 ◽  
Vol 89 (6) ◽  
pp. 2873-2879 ◽  
Author(s):  
Anna-Maria Andersson ◽  
Jørgen H. Petersen ◽  
Niels Jørgensen ◽  
Tina K. Jensen ◽  
Niels E. Skakkebæk

Abstract Inhibin B and FSH levels in 289 idiopathic infertile men were compared with reference materials consisting of 303 proven fertile men (reference group 1) and 307 healthy men from the general population with unknown fertility status (reference group 2). The diagnostic power of these two serum markers of spermatogenesis was evaluated by the use of receiver operating characteristic plot analysis, and an example of how both markers can be used simultaneously in a bivariate reference chart is presented. Inhibin B levels were significantly lower and FSH levels were significantly higher in the infertile men, compared with either reference group, but with significant overlap, especially with reference group 2. Nevertheless, approximately 50% of the infertile men had an inhibin B or FSH, respectively, below the 2.5 percentile or above the 97.5 percentile of reference group 1, whereas only approximately 25% of the infertile men had an inhibin B or FSH, respectively, below the 2.5 percentile or above the 97.5 percentile of reference group 2. Fourteen and 11% of reference group 2 had an inhibin B or FSH, respectively, below the 2.5 percentile or above the 97.5 percentile of reference group 1, suggesting that a significant number of individuals from the general population with unknown fertility but otherwise healthy may actually be subfertile. In conclusion, 1) proven fertile men constitute the most appropriate reference group in the evaluation of the FSH-inhibin B axis; the sensitivity of these markers to identify infertility increased by approximately 20% when fertile men rather than men from the general population were used as control group; 2) FSH alone had a slightly higher positive predictive value than inhibin B alone, but the positive predictive value were highest when both markers of spermatogenesis were used in an inhibin B/FSH ratio; and 3) a bivariate reference chart is a valuable objective tool in the simultaneous evaluation of FSH and inhibin B as two interrelated markers.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2019 ◽  
Vol 3 (s1) ◽  
pp. 38-38
Author(s):  
Safa Kaleem ◽  
Christa B. Swisher

OBJECTIVES/SPECIFIC AIMS: 1. Determine positive predictive value, negative predictive value, sensitivity, and specificity of Neuro ICU nurse interpretation of real-time bedside qEEG. 2. Determine difference in time to detection of first seizure between Neuro ICU nurse qEEG interpretation and EEG fellow reads of cEEG. 3. Determine what qualities of seizures make detection by neuro ICU nurses more or less likely – e.g. duration of seizures, type of seizures, spatial extent of seizures. METHODS/STUDY POPULATION: Recruit neuro ICU nurses taking care of 150 patients admitted to the Neuro ICU at Duke University Hospital who are initiated on cEEG monitoring. Nurses will be consented for their participation in the study. Neuro ICU nurses will evaluate the qEE RESULTS/ANTICIPATED RESULTS: From literature estimates of a 20% seizure prevalence in critical care settings, we hope to have 30 patients with seizures and 120 without. Based on prior study in the Duke Neuro ICU, we hypothesize that Neuro ICU nurses will have sensitivity and DISCUSSION/SIGNIFICANCE OF IMPACT: This is the first prospective study of neuro ICU nurse interpretation of real-time bedside qEEG in patients with unknown NCSE/NCS presence. If nurse sensitivity, specificity, and positive predictive value are clinically useful, which we deem would be so at a sensitivity of 70% or greater, with acceptable false alarm rate, nurse readings of qEEG could significantly decrease the time to treatment of seizures in the Neuro ICU patient population, and perhaps could improve patient outcomes.


Author(s):  
Dagmar Lagerberg ◽  
Margaretha Magnusson ◽  
Claes Sundelin

Abstract Background: The Edinburgh Postnatal Depression Scale (EPDS) is widely used in early child health care. This study examined the appropriateness of the recommended EPDS cut-off score 11/12. Methods: Two main analyses were performed: 1. Associations between EPDS scores and maternal health behaviour, stress, life events, perceived mother-child interaction quality and child behaviour. 2. Screening parameters of the EPDS, i.e., sensitivity, specificity and positive predictive value. EPDS scores were available for 438 mothers and maternal questionnaires for 361 mothers. Results: Already in the EPDS score intervals 6–8 and 9–11, there were notable adversities, according to maternal questionnaires, in stress, perceived quality of mother-child interaction, perceived child difficultness and child problem behaviours. Using maternal questionnaire reports about sadness/distress postpartum as standard, the recommended EPDS cut-off score 11/12 resulted in a very low sensitivity (24%). The cut-off score 6/7 yielded a sensitivity of 61%, a specificity of 82% and a positive predictive value of 61%. Conclusions: In terms of both clinical relevance and screening qualities, an EPDS cut-off score lower than 11/12 seems recommendable.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


2014 ◽  
Vol 47 (1) ◽  
pp. 28-32 ◽  
Author(s):  
Vilson Lacerda Brasileiro Junior ◽  
Aníbal Henrique Barbosa Luna ◽  
Marcelo Augusto Oliveira de Sales ◽  
Tânia Lemos Coelho Rodrigues ◽  
Priscilla Lopes da Fonseca Abrantes Sarmento ◽  
...  

Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57%) patients. Such individuals presented with a total of 29 (41.43%) carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50) of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001) was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.