scholarly journals Bond strength of different bracket bonding materials to the enamel subjected to thermal cycling

2015 ◽  
Vol 63 (1) ◽  
pp. 25-32
Author(s):  
Alcir ROSOLEN ◽  
Enrico Coser BRIDI ◽  
Roberta Tarkany BASTING

OBJECTIVE: The aim of this study was to evaluate in vitro the shear bond strength of metallic orthodontic brackets to enamel using different bonding materials followed by thermal cycling. METHODS: A fluid composite resin (Transbond XT / 3M Unitek) and a resin-modified glass ionomer (Fuji Ortho LC / GC America Inc.) were evaluated. Eighty sound human premolars were randomly divided into eight experimental groups (n = 10), according to the material used and the number of thermal cycles: zero, 1000, 2000 and 3000 cycles. Bracket bonding was performed on the buccal surface of the teeth. After 24 hours, they were subjected to thermal cycling at temperatures ranging between 5° C and 55° C for 15 seconds each immersion. Shear bond strength was performed using a universal testing machine with a chisel-type tip at a speed of 0.5 mm / min. The bond strength data was analyzed using two-way ANOVA. RESULTS: No difference on shear bond strength was observed regarding the number of thermal cycles for each specimen (p = 0.873). A significant difference was found in shear bond strength between the bonding materials (p = 0.022), with significantly higher values for Transbond XT regardless of the number of thermal cycles. CONCLUSION: The number of thermal cycles did not significantly affect the bond strength of the adhesive materials investigated. The bonding agent Transbond XT showed higher bond strength than Fuji Ortho LC regardless of the number of thermal cycles.

2012 ◽  
Vol 23 (4) ◽  
pp. 379-386 ◽  
Author(s):  
Adriano Augusto Melo de Mendonça ◽  
Camila Fávero de Oliveira ◽  
Josimeri Hebling ◽  
Carlos Alberto de Souza Costa

This study evaluated the transdentinal cytotoxicity (TC) and the bond strength (BS) of a resin-modified glass-ionomer cement (RMGIC) applied to dentin covered with smear layer (SL) of different thicknesses. Forty dentin discs had thick (TSL) or thin (THSL) smear layer created on their occlusal side. In artificial pulp chambers, MDPC-23 cells were seeded on the pulpal side of the dentin discs and divided into five groups: G1TC: no treatment (control); G2TC: TSL + RMGIC; G3TC: THSL + RMGIC; G4TC: TSL removal + RMGIC; G5TC: THSL removal + RMGIC. After 24 h, cell metabolism and morphology were evaluated by the methyltetrazolium (MTT) assay and by scanning electron microscopy (SEM), respectively. For BS, the following groups were determined: G1BS: TSL removal + RMGIC; G2BS: THSL removal + RMGIC; G3BS: TSL + RMGIC; G4BS: THSL + RMGIC. Shear bond strength was tested to failure in a mechanical testing machine MTS (0.5 mm/min). Statistically significant difference was observed only between the control and experimental groups (Kruskal-Wallis, p<0.05). The metabolic activity of the viable MDPC-23 cells in G2TC, G3TC, G4TC and G5TC decreased by 54.85%, 60.79%, 64.12% and 62.51%, respectively. Mean shear bond strength values for G1BS, G2BS, G3BS and G4BS were 7.5, 7.4, 6.4 and 6.7 MPa, respectively, without significant difference among them (ANOVA, p>0.05). RMGIC presented moderate transdentinal cytotoxic effects. Maintenance or removal of smear layer did not affect the bond strength of RMGIC to dentin substrate.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Monika Aleksiejunaite ◽  
Antanas Sidlauskas ◽  
Arunas Vasiliauskas

The purpose of this study was to determine the impact of different enamel preparation procedures and compare light cure composite (LCC) and resin-modified glass ionomer (RMGI) on the bond strength of orthodontic metal tubes rebonded to the enamel. Twenty human molars were divided into two groups (n=10). Tubes were bonded using LCC (Transbond XT) in group 1 and RMGI (Fuji Ortho LC) in group 2. The tubes in each group were bonded following manufacturers’ instructions (experiment I) and then debonded using testing machine. Then, the same brackets were sandblasted and rebonded twice. Before the first rebonding, the enamel was cleaned using carbide bur (experiment II) and before second rebonding, it was cleaned using carbide bur and soda blasted (experiment III). Mann–Whitney and Wilcoxon signed-rank tests showed no significant difference between RMGI and LCC bond strengths in case of normal bonding and rebonding, when enamel was cleaned using carbide bur before rebonding. Enamel soda blasting before rebonding significantly increased RMGI tensile bond strength value compared to LLC (p<0.05). LCC and RMGI (especially RMGI) provide sufficient bond strengths for rebonding of molar tubes, when residual adhesive from previous bonding is removed and enamel soda blasted.


2015 ◽  
Vol 5 (1) ◽  
pp. 22-26
Author(s):  
Muzin Shahi Shaik ◽  
Snigdha Pattanaik ◽  
Sudhakar Pathuri ◽  
Arunachalam Sivakumar

Introduction: Bond strength is an important property and determines the amount of force delivered and treatment duration in orthodontics. Many light-cured bonding materials are being used; but it is required to determine the most efficient one withdesired bond strength. Objective: To determine and compare the shear bond strength of three visible light-cured composites (Transbond XT, Heliositand Enlight) and two self-cured composites (Rely-a-bond and Concise). Materials & Method: 100 extracted premolars were collected and randomly divided into 5 test groups of different adhesives. Brackets were bonded to the teeth in each test group with the respective adhesive according to the manufacturer’s instructions. Each specimen was debonded using Universal Testing Machine and the shear bond strength for each specimen was calculated. All the groups were compared by ANOVA one-way test. Results: There were statistically significant differences among the five groups (P<0.05). The shear bond strength of Enlight (13.92 ± 3.92) is similar to Transbond XT (14.30 ± 4.35). Conclusion: Light cure composites showed higher bond strength than self cure composites.


2018 ◽  
Vol 29 (2) ◽  
pp. 128-132 ◽  
Author(s):  
Gabriela Cristina Santin ◽  
Alexandra Mussolino de Queiroz ◽  
Regina Guenka Palma-Dibb ◽  
Harley Francisco de Oliveira ◽  
Paulo Nelson Filho ◽  
...  

Abstract Patients undergoing radiotherapy treatment present more susceptibility to dental caries and the use of an orthodontic device increases this risk factor due to biofilm accumulation around the brackets. The objective of this study was to evaluate the shear bond strength to irradiated permanent teeth of orthodontic brackets bonded with conventional glass ionomer cement and resin-modified glass ionomer cement due to the fluoride release capacity of these materials. Ninety prepared human premolars were divided into 6 groups (n=15), according to the bonding material and use or not of radiation: CR: Transbond XT composite resin; RMGIC: Fuji Ortho LC conventional glass ionomer cement; GIC: Ketac Cem Easymix resin-modified glass ionomer cement. The groups were irradiated (I) or non-irradiated (NI) prior to bracket bonding. The specimens were subjected to a fractioned radiation dose of 2 Gy over 5 consecutive days for 6 weeks. After the radiotherapy, the brackets were bonded on the specimens with Transbond XT, Fuji Ortho LC and Ketac Cem Easymix. After 24 h, the specimens were subjected to shear bond strength test. The image of enamel surface (classified by Adhesive Remnant Index - ARI) was also evaluated and its frequency was checked among groups/subgroups. The shear bond strength variable was evaluated with ANOVA and Tukey’s post-hoc test. GIC group showed the lowest adhesion values among the groups (p<0.05). There was no statistically significant difference among non-irradiated and irradiated groups (p>0.05). As for the ARI, the CR-I group showed the highest material retention on enamel surface among the irradiated groups. RMGIC group showed the highest values for shear bond strength and presented ARI acceptable for clinical practices.


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


Author(s):  
Kiana Poorzandpoush ◽  
Mehdi Shahrabi ◽  
Alireza Heidari ◽  
Zohre Sadat Hosseinipour

Objectives: This study aimed to compare the shear bond strength (SBS) of self-adhesive and conventional flowable composites and resin-modified glass-ionomer cement (RMGIC) to primary dentin. Materials and Methods: In this in vitro, experimental study, the buccal surface of 48 primary canine and first molar teeth was longitudinally sectioned to expose dentin. The teeth were randomly divided into three groups (n=16) of 37.5% phosphoric acid+ OptiBond+ Premise Flow composite (group 1), Vertise Flow composite (group 2) and RMGIC (group 3). A plastic cylindrical mold was placed on the exposed dentin and filled with restorative materials. The samples were then immersed in distilled water at 37°C for 24 hours, subjected to 1000 thermal cycles between 5-55°C and underwent SBS test. The mode of failure was determined under a stereomicroscope. Data were analyzed using one-way ANOVA and Tukey’s test. Results: A significant difference was noted in SBS of the groups (P<0.05). The SBS of conventional flowable composite was significantly higher that of RMGIC and self-adhesive flowable composite (P<0.05). The difference in SBS of RMGIC and self-adhesive flowable composite was not significant (P>0.05). Failure at the dentin-restoration interface (adhesive failure) had the highest frequency in groups 1 and 2. The frequency of adhesive failure was 100% in group 3. Conclusions: Within the limitations of this study, the conventional flowable composite yielded the highest SBS to primary dentin. Self-adhesive flowable composite and RMGIC showed the lowest SBS with no significant difference with each other.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


Author(s):  
Anjna Sharma ◽  
Pankaj Mishra

ABSTRACT Aim To compare the compressive strengths of composite resins and resin-modified glass ionomer cements (RMGICs) at different times. Materials and methods A total of 36 samples were prepared, 12 samples of each group, composite resins Filtek Z 250, Filtek Z 350, and resin-modified glass ionomer cement. Compressive strengths of specimens were measured after 1, 24 hours, and 7 days. Test was carried out on a “Universal Testing Machine” with cross-head speed of 5 mm/min. Results There was a significant difference between all the three restorative materials. Analysis of variance showed that mean compressive strengths of Z 250 after 1, 24 hours were higher than Z 350 and RMGIC (p < 0.05). The mean compressive strengths were reduced after 7 days in all the three groups, but after 7 days, the values of Z 250 when compared with the Z 350 and RMGIC were higher. Conclusion The study demonstrated that compressive strengths of hybrid composite resins (Z 250) were significantly higher than that of nanocomposites (Z 350) and RMGIC. How to cite this article Sharma A, Mishra P, Mishra SK. Time-dependent Variation in Compressive Strengths of Three Posterior Esthetic Restorative Materials: An in vitro Study. Int J Prosthodont Restor Dent 2016;6(3):63-65.


Sign in / Sign up

Export Citation Format

Share Document