Study on Anti-explosion Protection of Composite Steel Plate Lining Structure

Author(s):  
Desen Kong ◽  
Yazhou Li ◽  
Cheng Song ◽  
Meixu Deng
2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Desen Kong ◽  
Yu Xu ◽  
Cheng Song

According to the advantages of high tensile resistance and high shear strength of composite steel plate, a new antiexplosion protection method of composite steel plate lining structure is put forward. The numerical model of explosion impact of subway tunnel with composite steel plate lining structure was established by dynamic analysis software. The transient dynamic response of lining structure with the composite steel plate was simulated when explosion occurred. The research results show that the influence of explosive quantity on each point of composite steel plate lining structure is different and the change of acceleration near the centre of the detonation source is generally greater than the multiple of the increase of explosive quantity. The increase of velocity and displacement is basically consistent with the quantity of explosive. The influence of axial stress on the lining structure is the least, and the influence of the lining structure is greater in the y-direction than in the x-direction. The research results can provide the plan and basis for the emergency response of the subway tunnel.


2014 ◽  
Vol 14 (3) ◽  
pp. 479-488 ◽  
Author(s):  
Liqiang Jiang ◽  
Hong Zheng ◽  
Yuan Liu ◽  
Xiaosa Yuan

2013 ◽  
Vol 671-674 ◽  
pp. 1408-1413
Author(s):  
Ning Zhou ◽  
Feng Xiong ◽  
Qun Yi Huang ◽  
Qi Ge ◽  
Jiang Chen

Composite steel plate shear wall (CSPSW), as a new lateral force resisting structure composed of steel plate and concrete slab, is introduced. CSPSWs can fully display the superiority of the steel plate and concrete. Ductility and energy dissipation capacity of the walls are increased and seismic behavior is improved. Recent seismic research around the word of two kinds of CSPSWs, namely, CSPSW with signal steel plate and CSPSW with double steel plates, is presented and discussed comprehensively. Some existing problems in current research of the walls are also reviewed in this paper.


2012 ◽  
Vol 166-169 ◽  
pp. 636-639
Author(s):  
Lin Lin Wu ◽  
Yong Guang Lian ◽  
Yong Xiang Kong ◽  
Yong Jun Ma ◽  
Bin Jiang ◽  
...  

The damage mechanism and causes of the shaft lining structures are introduced, and the advantages and disadvantages of some current shaft lining structures are analyzed. The prospects of steel plate-high strength concrete composite shaft lining structure are proposed in this paper.


2017 ◽  
Vol 16 (2) ◽  
pp. 249-261 ◽  
Author(s):  
Hossein Khosravi ◽  
◽  
Sayed Shoaib Mousavi ◽  
Gholamreza Tadayonfar ◽  
◽  
...  

2004 ◽  
pp. 371-376
Author(s):  
Henglin Lv ◽  
Jinghua Li ◽  
Wei Liu ◽  
Shuchun Zhou

2020 ◽  
Vol 10 (8) ◽  
pp. 2938
Author(s):  
Zhishu Yao ◽  
Ping Zhang ◽  
Hua Cheng ◽  
Weipei Xue ◽  
Xiang Li

To address the support problem of large-diameter drilling shafts in the west area of Zhangji coal mine, a thinner shaft lining structure composed of double layers of steel plate and high-performance concrete is proposed herein. Firstly, a series of tests of high-performance concrete preparation were carried out, and the optimized mix ratio of pumping concrete with 60–70 MPa strength for shaft lining of the drilled shaft was obtained. Then, shaft lining models were designed according to the similarity theory, and the mechanical properties of the shaft lining were experimentally studied by loading test. The test results showed that the stress state of concrete in the shaft was obviously improved, and the compressive strength of concrete was increased by 1.97–2.52 times. Finally, the results of the study were applied to a shaft in the control strata of the inlet shaft in the west area of Zhangji coal mine, which made it possible to use the drilling method to construct the shaft. The following field measurement showed that the annular strain of the shaft lining concrete was −487 με, which is far less than the ultimate strain value of C65 concrete, and the shaft lining structure was kept safe and reliable.