scholarly journals Stress distribution around dental implants, generated by six different ceramic materials for unitary restoration: An experimental photoelastic study

2021 ◽  
Vol 58 (4) ◽  
pp. 0-0
Author(s):  
Santiago Abarno ◽  
Arthur Gehrke ◽  
Berenice Dedavid ◽  
Sergio Gehrke
Author(s):  
João PO Freitas ◽  
Bruno Agostinho Hernandez ◽  
Paulo J Paupitz Gonçalves ◽  
Edmea C Baptista ◽  
Edson A Capello Sousa

Dental implants are widely used as a long-term treatment solution for missing teeth. A titanium implant is inserted into the jawbone, acting as a replacement for the lost tooth root and can then support a denture, crown or bridge. This allows discreet and high-quality aesthetic and functional improvement, boosting patient confidence. The use of implants also restores normal functions such as speech and mastication. Once an implant is placed, the surrounding bone will fuse to the titanium in a process known as osseointegration. The success of osseointegration is dependent on stress distribution within the surrounding bone and thus implant geometry plays an important role in it. Optimisation analyses are used to identify the geometry which results in the most favourable stress distribution, but the traditional methodology is inefficient, requiring analysis of numerous models and parameter combinations to identify the optimal solution. A proposed improvement to the traditional methodology includes the use of Design of Experiments (DOE) together with Response Surface Methodology (RSM). This would allow for a well-reasoned combination of parameters to be proposed. This study aims to use DOE, RSM and finite element models to develop a simplified optimisation analysis method for dental implant design. Drawing on data and results from previous studies, two-dimensional finite element models of a single Branemark implant, a multi-unit abutment, two prosthetic screws, a prosthetic crown and a region of mandibular bone were built. A small number of combinations of implant diameter and length were set based on the DOE method to analyse the influence of geometry on stress distribution at the bone-implant interface. The results agreed with previous studies and indicated that implant length is the critical parameter in reducing stress on cortical bone. The proposed method represents a more efficient analysis of multiple geometrical combinations with reduced time and computational cost, using fewer than a third of the models required by the traditional methods. Further work should include the application of this methodology to optimisation analyses using three-dimensional finite element models.


1982 ◽  
Vol 16 (4) ◽  
pp. 369-379 ◽  
Author(s):  
S. D. Cook ◽  
J. J. Klawitter ◽  
A. M. Weinstein

2012 ◽  
Vol 2 (1) ◽  
pp. 19 ◽  
Author(s):  
Bobin Saluja ◽  
Masood Alam ◽  
T Ravindranath ◽  
A Mubeen ◽  
Nidhi Adya ◽  
...  

1971 ◽  
Vol 93 (2) ◽  
pp. 538-544 ◽  
Author(s):  
S. Ramalingam

This paper extends the photoelasticity studies reported in Part 1 of this paper to the plastic regions associated with chip formation during orthogonal cutting. These regions include the deformation zone, the tool-chip interface and the chip itself. Problems connected with quantitative studies involving photoplasticity techniques are discussed. Qualitative interpretation of the photoplasticity observations carried out under dynamic cutting conditions are offered. Some comments regarding the role of the residual stresses in the chip in influencing the types of chips formed during cutting are made.


Sign in / Sign up

Export Citation Format

Share Document