Evaluation of Scintillation Camera Applications of 3D Printing Phantom

2021 ◽  
Vol 44 (4) ◽  
pp. 343-350
Author(s):  
Hoon-Hee Park ◽  
◽  
Ju-young Lee ◽  
Ji-Hyeon Kim
Nature ◽  
2013 ◽  
Vol 494 (7436) ◽  
pp. 174-174 ◽  
Author(s):  
Michael Pawlyn
Keyword(s):  

Nature ◽  
2020 ◽  
Vol 588 (7839) ◽  
pp. 594-595
Author(s):  
Cameron Darkes-Burkey ◽  
Robert F. Shepherd
Keyword(s):  

1975 ◽  
Vol 14 (04) ◽  
pp. 330-338
Author(s):  
L. G. Colombetti ◽  
J. S. Arnold ◽  
W. E. Barnes

SummaryTc-99m pyridoxylidene glutamate has proven to be an excellent biliary scanning agent, far superior in many respect to the commonly used 1-131 rose bengal. The preparation of the compound as previously reported by Baker et al is too time consuming and requires the use of an autoclave which is not available in most nuclear medicine departments. In our facility, we have been preparing similar compounds using several aldehydes and monosodium glutamate to make labeled complexes having the same pharmacological characteristics. The mixture of monosodium glutamate, aldehyde, and Tc-99m pertechnetate is made slightly alkaline, purged with helium, and placed in a sealed vial. The vial, which is protected by a wire basket, is then heated in a laboratory oven at 130° C for a period of 15 to 20 minutes. During this time, the technetium is reduced to a lower valence state and bound to the complex formed. Chromatographic data show that these compounds are chemically similar to that previously reported. The compounds prepared concentrate in the gall bladder of the rabbit in less than 10 minutes. Kinetic studies have been performed on dogs with a scintillation camera and small digital computer to measure rates of blood clearance, liver and gall bladder uptake, and excretion into the intestine. The aldehyde — glutamate complex promises to be a useful scanning agent for the diagnosis of biliary and hepatocellular diseases.


1971 ◽  
Vol 10 (02) ◽  
pp. 122-128
Author(s):  
W. H. Blahd ◽  
M. A. Winston ◽  
G. T. Krishnamurthy ◽  
P. B. Thomas ◽  
E. Weiss

SummaryBecause of its speed, accuracy, and reproducibility, radioisotopic angiocardiography appears to be the method of choice for the diagnosis of pericardial effusion. Technetium-99m sulfide is preferable to 99mTc sodium pertechnetate in these studies for the following reasons: (1) its specific uptake by the liver aids both in patient positioning and in the accuracy of diagnosis; and (2), studies can be repeated within 15—20 minutes should there be equiment or technical error.


1983 ◽  
Vol 22 (05) ◽  
pp. 246-250 ◽  
Author(s):  
M. Al-Hilli ◽  
H. M. A. Karim ◽  
M. H. S. Al-Hissoni ◽  
M. N. Jassim ◽  
N. H. Agha

Gelchromatography column scanning has been used to study the fractions of reduced hydrolyzed 99mTc, 99mTc-pertechnetate and 99mTc-chelate in a 99mTc-glucoheptonate (GH) preparation. A stable high labelling yield of 99mTc-GH complex in the radiopharmaceutical has been obtained with a concentration of 40-50 mg of glucoheptonic acid-calcium salt and not less than 0.45 mg of SnCl2 2 H2O at an optimal pH between 6.5 and 7.0. The stability of the complex has been found significantly affected when sodium hydroxide solution was used for the pH adjustment. However, an alternative procedure for final pH adjustment of the preparation has been investigated providing a stable complex for the usual period of time prior to the injection. The organ distribution and the blood clearance data of 99mTc-GH in rabbits were relatively similar to those reported earlier. The mean concentration of the radiopharmaceutical in both kidneys has been studied in normal subjects for one hour with a scintillation camera and the results were satisfactory.


1981 ◽  
Vol 45 (03) ◽  
pp. 208-210 ◽  
Author(s):  
D Green ◽  
S M Spies ◽  
N A Rana ◽  
J W Milgram ◽  
R Mintzer

SummaryThe technique of blood pool scanning was used to examine 15 hemophilic subjects. Employing an in vivo method for erythrocyte labeling with Technetium-99 m, a dynamic perfusion sequence is obtained using a scintillation camera positioned over the area to be examined. This demonstrates the vascularity of the tissue. Subsequently, equilibrium blood pool images of the area are obtained and analyzed with a densitometer to assess relative regional blood volume. In patients who were not bleeding but had chronic arthropathy, vascularity was not increased, and the blood volume of comparable joints was similar. By contrast, marked increases in vascularity and image density were observed in studies of acutely bleeding joints. Chronic hemarthroses were associated with persistent, but less marked increases in joint perfusion. Transient increases in joint vascularity were demonstrated after insertion of knee prostheses. In a patient with a thigh hematoma, the dimensions of the hemorrhage were clearly delineated. Since only a tracer dose of nuclide is infused intravenously, there are no allergic reactions or other side effects of the procedure. Blood pool scanning is a safe, non-invasive technique that augments clinical and radiographic evaluations, and provides a new dimension in the assessment of the hemophilic patient.


1985 ◽  
Vol 53 (03) ◽  
pp. 423-427 ◽  
Author(s):  
Stephen R Hanson ◽  
Laurence A Harker

SummarySuloctidil has been evaluated in the baboon for its antithrombotic efficacy using models of both acute and chronic arterial thrombogenesis. Acute thrombus formation was initiated by Dacron vascular grafts inserted as extension segments into chronic arteriovenous shunts. 111In-platelet deposition was measured by scintillation camera imaging for one hour. The results after oral administration of suloctidil (100 mg/kg/d in two divided doses) were not different from control studies. Moreover, concurrent heparin anticoagulation did not affect 111In-platelet deposition compared with control data. In contrast, ticlopidine (20 mg/ kg/d) significantly decreased platelet deposition that was reduced further by the addition of heparin.Chronic arterial-thromboembolism was initiated by segments of polyurethane (Biomer) cannula introduced into chronic arteriovenous shunts. Thrombus formation by the polyurethane cannula was measured as 111In-platelet turnover (corrected for removal of senescent platelets). Cannula platelet consumption was unaffected by suloctidil (20 mg/kg/d given in two divided doses for two days preceding and throughout the period of platelet survival measurement). In contrast, dipyridamole (10 mg/ kg/d) and sulfinpyrazone (100 mg/kg/d) completely interrupted cannula platelet consumption.We conclude that suloctidil probably has little or no effect on platelet-dependent thrombus formation.


Author(s):  
Thomas Birtchnell ◽  
William Hoyle
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document