scholarly journals Harmonics generated by Electric Arc Furnace in Electric Power System - A Review

Author(s):  
Ashutosh Srivastava ◽  
Amarjeet Singh

An electrical power system is designed to operate at the frequency of 50 Hz or 60 Hz. But there are certain loads which generate voltage and current that are the integer multiple of 50 or 60 Hz. Those higher frequencies form electrical network pollution called as power system harmonics. An Electric Arc Furnace (EAF) is one of such load when operated on AC affects the power quality of the power system. The power quality is degraded mainly due to the poor power factor, current and voltage harmonics and voltage fluctuation. The problems due the harmonics is getting worsen day by day due to the introduction of power electronics equipments and voltage fluctuation arise by the use of large industrial load such as EAFs and LMF (Ladle Melt Furnace) in steel meting shop. Also connecting rolling mill and forging shop generate harmonics in the adjacent electrical power system. In this paper, an extensive review of harmonics generated in EAF is presented .

Author(s):  
Amarjeet Singh

The nonlinear and time varying nature of Electric Arc Furnace (EAF) causes power quality problems such as harmonics, flicker and voltage /current imbalances. In order to analyze the power quality of power system containing EAF, mathematical model of arc furnace becomes useful and informative. This paper presents different models of alternating current operated arc furnace to analyze the power quality in electric power system. The behavior of these models under static and dynamic conditions is studied. A comparison is also made between these models of arc furnace. Simulation results in MATLAB/ SIMULINK shows the voltage/current wave forms and percentage harmonic component in arc furnace system.


Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong

Three-phase AC electric arc furnace (EAF) is a typical non-linear load, causing many power quality problems. Most of the researches on the voltage problems of EAF mainly focus on the voltage fluctuation, and less on the transient voltage problems caused by EAF short circuit and open circuit. In this paper, the relationship between voltage and current of EAF is obtained by combining hyperbolic function and exponential function, then the white noise and chaotic circuit are added to establish the EAF model which is suitable for the study of voltage fluctuation and transient voltage. This paper analyzes the causes of the transient voltage problem of the EAF, calculates the short-circuit current, reactive impact and the influence on voltage at the point of common coupling (PCC) in the three-phase short-circuit of the EAF, and compares the calculation results with the simulation results to prove the accuracy of this model. The results show that the reactive impact of three-phase short circuit is about twice as much as that of normal operation of EAF, resulting in about 30% voltage sag at the PCC, which is very unfavorable to the power grid. This paper provides reference for transient power quality evaluation and dynamic reactive power compensation of EAF.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2699
Author(s):  
Marceli N. Gonçalves ◽  
Marcelo M. Werneck

Optical Current Transformers (OCTs) and Optical Voltage Transformers (OVTs) are an alternative to the conventional transformers for protection and metering purposes with a much smaller footprint and weight. Their advantages were widely discussed in scientific and technical literature and commercial applications based on the well-known Faraday and Pockels effect. However, the literature is still scarce in studies evaluating the use of optical transformers for power quality purposes, an important issue of power system designed to analyze the various phenomena that cause power quality disturbances. In this paper, we constructed a temperature-independent prototype of an optical voltage transformer based on fiber Bragg grating (FBG) and piezoelectric ceramics (PZT), adequate to be used in field surveys at 13.8 kV distribution lines. The OVT was tested under several disturbances defined in IEEE standards that can occur in the electrical power system, especially short-duration voltage variations such as SAG, SWELL, and INTERRUPTION. The results demonstrated that the proposed OVT presents a dynamic response capable of satisfactorily measuring such disturbances and that it can be used as a power quality monitor for a 13.8 kV distribution system. Test on the proposed system concluded that it was capable to reproduce up to the 41st harmonic without significative distortion and impulsive surges up to 2.5 kHz. As an advantage, when compared with conventional systems to monitor power quality, the prototype can be remote-monitored, and therefore, be installed at strategic locations on distribution lines to be monitored kilometers away, without the need to be electrically powered.


2002 ◽  
Vol 12 (06) ◽  
pp. 1333-1356 ◽  
Author(s):  
YOSHISUKE UEDA ◽  
HIROYUKI AMANO ◽  
RALPH H. ABRAHAM ◽  
H. BRUCE STEWART

As part of an ongoing project on the stability of massively complex electrical power systems, we discuss the global geometric structure of contacts among the basins of attraction of a six-dimensional dynamical system. This system represents a simple model of an electrical power system involving three machines and an infinite bus. Apart from the possible occurrence of attractors representing pathological states, the contacts between the basins have a practical importance, from the point of view of the operation of a real electrical power system. With the aid of a global map of basins, one could hope to design an intervention strategy to boot the power system back into its normal state. Our method involves taking two-dimensional sections of the six-dimensional state space, and then determining the basins directly by numerical simulation from a dense grid of initial conditions. The relations among all the basins are given for a specific numerical example, that is, choosing particular values for the parameters in our model.


2021 ◽  
Vol 15 (1) ◽  
pp. 75-83
Author(s):  
Ngoc Toan Luong ◽  
◽  
Duc Tung Doan

Actual analysis showed that the arc furnace current contains many harmonics that adversely affect the power quality. There are many domestic and foreign reports on modeling and assessing the impact of EAF on the grid based on different models. However, EAF's selection of capacity for research and application of power quality improvement devices suitable to the power level has not been mentioned, these models are mainly built on Matlab Simulink software. should be primarily academic. PSCAD is one of the widely used software for electrical system simulation and is used by large companies such as ABB, Korean power corporation Kepco. Building EAF model with PSCAD software will increase the ability to apply simulation results into practice. The objective of the paper is to build an electric arc furnace model based on the energy conservation model with PSCAD software, thereby assessing the change of parameters in the model and the effect of this load on electricity grid during operation.


Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong ◽  
Zhengguang Liu

The overrun of transient power quality index caused by the large-capacity electric arc furnace (EAF) has become a prominent problem affecting the safe and stable operation of the power system. (1) In this paper, the relationship between arc furnace volt-age and current is derived based on the different stages of arc combustion, and the random variation of chaotic phenomenon of the arc voltage are simulated. Established an EAF model suitable for the study of transient power quality problems. (2) Take 50t AC EAF as an example to analyze the reactive power impact and the influence on the point of common coupling (PCC) voltage caused by the three-phase short circuit of the electrode. The results show that the experimental results are consistent with the theoretical analysis, verifying the correctness and effectiveness of the model. (3) When the three-phase short-circuit occurs, the reactive power impact is nearly 6 times that of normal operation, the short-circuit current is 2.66 times that of normal operation, and the effective value of the PCC voltage has dropped by 40.37%, which provides a theoretical basis for real-time compensation of impulsive reactive power and improvement of the transient power quality of the EAF.