scholarly journals Study of risk factors and perinatal outcome in meconium stained deliveries from a district of Uttar Pradesh, India

Author(s):  
Richa Rathoria ◽  
Ekansh Rathoria ◽  
Utkarsh Bansal ◽  
Madhulika Mishra ◽  
Ila Jalote ◽  
...  

Background: The objective is to identify the risk factors of Meconium stained deliveries and evaluate the perinatal outcomes in Meconium Stained deliveries.Methods: This prospective observational study included those pregnant women who had completed 37 weeks of gestation, with singleton pregnancies with cephalic presentations and with no known fetal congenital anomalies. Among these, we selected 110 cases with Meconium stained amniotic fluid and they were compared with 110 randomly selected controls.Results: Regular antenatal visits were seen in 22.73 % of the cases while 77.27% cases had no previous visit. Majority of cases were primigravida and gestational ages of >40 weeks was seen in 55.45 % cases. 19.09% cases had meconium staining among pregnancies complicated with pregnancy induced hypertension, as compared to those among controls (5.45%). Fetal heart rate abnormalities were seen in 29.09% cases, and statistically significant fetal bradycardia was seen in cases. Caesarean section rates were nearly double in cases (54.55%). Poor perinatal outcome was found in cases as seen in results by low Apgar score (<7) at 1 minute and 5-minute, higher incidence of birth asphyxia, Meconium Aspiration Syndrome and increased NICU admission as compared to that among controls.Conclusions: Meconium stained amniotic fluid is more commonly associated with higher gestational age >40 weeks, pregnancy induced hypertension and fetal bradycardia, increased cesarean section rates, low APGAR score and higher incidence of birth asphyxia and NICU admissions. Meconium aspiration syndrome was associated with early neonatal death.

Author(s):  
Kapil Singh Niranjan ◽  
Pesona Grace Lucksom

Background: Meconium staining of amniotic fluid (MSAF) is a significant risk factor for the subsequent development of meconium aspiration syndrome (MAS), respiratory distress and eventual respiratory failure in neonates. To learn more about the risk factors and outcomes associated with MSAF, a prospective case control study was conducted. The objective of the study was to study various maternal risk factors associated with MSAF and to study the outcome of neonates born through MASF and to compare the perinatal outcome in patients with thick and thin meconium stained amniotic fluid.Methods: A hospital based prospective case control study was conducted comparing pregnant women with meconium stained (cases) amniotic fluid with pregnant women having clear liquor (control), 200 in each arm. Singleton pregnancies complicated with MASF were included in the cases group on the basis of predefined inclusion criteria. Various risk factors, mode of delivery, outcome of neonates and perinatal outcome in babies born through thick and thin meconium stained amniotic fluid was studied.Results: Out of 200 patients who had MSAF 114 patients (57%) had thick meconium stained liquor while remaining 86 patients (43.00%) had thin meconium stained amniotic fluid. Post-maturity, pregnancy induced hypertension; oligohydramnios and prolonged labor were found to be statistically significant risk factors for MSAF. Nonreactive non-stress test and Need for cesarean section was more common in women with MSAF as compared to women with clear liquor (p <0.05). Common morbidities in neonates were Birth asphyxia (15%) followed by meconium aspiration syndrome (10%) and hypoxic ischemic encephalopathy (15%).Conclusions: Meconium stained amniotic fluid is more commonly associated with post-maturity, pregnancy induced hypertension, oligohydramnios and prolonged labor low APGAR score and higher incidence of birth asphyxia and NICU admissions. Appropriate management of neonates with meconium aspiration syndrome is crucial to prevent neonatal mortality.


2021 ◽  
pp. 48-50
Author(s):  
Neha Agarwal ◽  
Samta Bali Rathore ◽  
Shivani Baberwal-

BACKGROUND: Occurance of meconium-stained amniotic uid (MSAF) during labour may be considered as a measure for prediction of poor fetal outcomes such as meconium aspiration syndrome and perinatal asphyxia ,resulting in perinatal as well as neonatal morbidity and mortality. It constitutes about 5% of deliveries with meconium stained amniotic uid and death results in about 12% of infants with MAS. METHODS: 40 cases of meconium stained liquor detected after spontaneous or artical rupture of membranes taken during labour from june 2020 to december 2020 and their outcome in terms of mode of delivery(whether vaginal delivery or lower segment caesarean section) and fetal outcome and associated maternal high risk were studied RESULT: Anemia was co existant in around 15%, pregnancy induced hypertension(PIH) in 25%and premature rupture of membrane in 10%.Pregnancies complicated with Pregnancy induced hypertension had signicant higher rate of meconium stained liquor among all cases. Caesarean Section was commonly performed in meconium stained amniotic uid cases and accounted for about 65%of all cases. CONCLUSIONS: Meconium Stained amniotic uid increases the chances of caesarean rates,leading to birth asphyxia ,Meconium Aspiration Syndrome and hence increases the chances of neonatal intensive unit admission.


2015 ◽  
Vol 4 (2) ◽  
pp. 44-49 ◽  
Author(s):  
Nasrin Begum ◽  
Sharmeen Mahmood ◽  
Salma Akhter Munmun ◽  
MS Haque ◽  
KN Nahar ◽  
...  

Objectives: To evaluate perinatal outcome associated with meconium stained amniotic fluid in pregnant women.Methods: It was a prospective cross sectional study, conducted in the Department of Obstetrics and Gynecology in Bangabandhu Sheikh Mujib Medical University, Dhaka, from January 2013 to December 2013. Total 50 pregnant women admitted in the labour ward for delivery with meconium stained amniotic fluid were the study population. Singleton pregnancy of more than 34 weeks duration was included and pregnancy with APH, breech presentation, congenital malformation of fetus, IUD were excluded from the study. Out of 50 patients two did not provide all the information needed to analyze the data and hence were excluded. Outcome Variables were gestational age, antenatal checkup, medical diseases of mother (HTN, Diabetes mellitus, Heart disease), obstetric complication (oligohydramnios, prolonged labour), mode of delivery, neonatal details (weight of the baby in kg, APGAR scoring at 1 min & 5 min), neonatal resuscitation, admission in neonatal ICU(NICU), neonatal complications (RDS, MAS, Neonatal death).Results: Over half (52.1%) of the neonates needed resuscitation and 54.2% admitted in ICU. About 90% of the neonates had normal birth weight and only 10.4% were of low birth weight. 14.6% of the neonates developed meconium aspiration syndrome and 10.4% respiratory distress syndrome. Neonatal jaundice and neonatal sepsis were observed in 4.2% neonates each. Four neonates (8.3%) died early in the neonatal life, while 1 (2.1 %) was still-born. Low APGAR score (<7) at 1 and 5 minutes of birth was found in 64.7% and 52.9% of the cases respectively with thick meconium stained amniotic fluid as opposed to 25.8% and 16.1% of the cases respectively having thin meconium stained amniotic fluid (p = 0.008 and p = 0.007 respectively). Thick meconium was significantly associated with meconium aspiration syndrome (p = 0.003). Neonates needing immediate resuscitation and admission in ICU was staggeringly higher in the former group than those in the later group (p = 0.002). The incidence of perinatal death was significantly higher in patients with thick meconium stained amniotic fluid than that in patients with thin meconium ( p= 0.021).Conclusion: Meconium stained amniotic fluid was associated with low APGAR score, higher incidence of MAS, ICU admission and perinatal death.J. Paediatr. Surg. Bangladesh 4(2): 44-49, 2013 (July)


Author(s):  
Alfiati Nanda Widiyaningrum ◽  
◽  
Bhisma Murti ◽  
Eti Poncorini Pamungkasari ◽  
◽  
...  

ABSTRACT Background: Meconium aspiration syndrome refers to the aspiration of meconium and amniotic fluid by the fetus. It can occur when the fetus is still in the uterus, passing through the birth canal or when it takes its first breath after birth. Meconium aspiration is a serious condition with high morbidity and mortality. This study aimed to examine the effect of meconium stained amniotic fluid on the risk of infants asphyxia. Subjects and Method: Meta analysis and systematic review was conducted by collecting published articles from PubMed, Google Scholar, Clinical Key, Science Direct, and Springer Link databases. Keywords used risk factor, asphyxia, birth asphyxia, meconium stained amniotic, meconium stained liquor, and cross sectional. The inclusion criteria were full text, using English language, using cross-sectional study design, and reporting adjusted odds ratio. The study population was infants. Intervention was meconium stained amniotic liquid with comparison clean amniotic liquid. The study outcome was asphyxia. The collected articles were selected by PRISMA flow chart. The quantitative data were analyzed by fixed effect model using Revman 5.3. Results: 7 studies from Ethiopia reported that meconium stained amniotic fluid increased the risk of asphyxia in infants 5.83 (aOR= 5.83; CI 95%= 4.15 to 8.20; p <0.001). Conclusion: Meconium stained amniotic fluid increases the risk of asphyxia in infants. Keywords: meconium, amniotic fluid, asphyxia, infants Correspondence: Alfiati Nanda Widiyaningrum. Masters Program in Public Health, Universitas Sebelas Maret. Jl. Ir. Sutami 36A, Surakarta 57126, Central Java. Email: [email protected]. Mobile:081327524537. DOI: https://doi.org/10.26911/the7thicph.03.130


2015 ◽  
Vol 35 (1) ◽  
pp. 44-48 ◽  
Author(s):  
SM Gurubacharya ◽  
S Rajbhandari ◽  
R Gurung ◽  
A Rai ◽  
M Mishra ◽  
...  

Introduction: The incidence of meconium aspiration syndrome is still high in the developing world contributing significantly to the neonatal mortality. The study was aimed to know the risk factors contributing to meconium aspiration syndrome and neonatal outcome in a tertiary government hospital of the country.Materials and Methods: It was a hospital based cross sectional study done over a period of three months. All live newborns born through meconium stained liquor were enrolled and all the details regarding mother, neonate were recorded. Odd’s ratio and bivariate analysis was done to assess the risk factors for meconium aspiration syndrome.Result: Out of all the deliveries 14.6% were meconium stained amniotic fluid and meconium aspiration syndrome developed in 6.6% of the neonates. Low Apgar score and premature rupture of membranes was significantly associated with the risk of occurrence of meconium aspiration syndrome. Neonates who developed meconium aspiration syndrome had mortality of 11.3%.Conclusion: Perinatal asphyxia and premature rupture of membranes were significantly associated with the development of meconium aspiration syndrome and neonates who developed meconium aspiration syndrome had high mortality.J Nepal Paediatr Soc 2015;35(1):44-48


Author(s):  
Defairlin Ranee ◽  
Deepa S. Phirke

Background: Meconium staining of amniotic fluid (MSAF) is a relatively common problem occuring in 10-25% of all deliveries. Meconium aspiration syndrome is more common in term babies than in preterm babies with rising frequency along with increase in gestational age of the fetus. Meconium stained amniotic fluid generally indicates sign of fetal distress. The objective of this study was to study clinical profile of meconium aspiration syndrome and the probable risk factors for meconium aspiration syndrome.Methods: It is a prospective observational sectional study conducted in NICU of department of paediatrics of tertiary care centre from 1st January 2015 to 30th June 2016.Results: In this study both sexes were equally affected, majority of the neonates were above 2.5kg and only very few (2 neonates) were less than 1.5kg. majority of the neonates were full term, it was found that there is a significant association between thick MSAF and the development of MAS, it was found that there is a significant association between low APGAR score at 1 minutes and the development of MAS, there is a strong association between thick MSAF and mortality in MSAF babies. Anemia 38 (25%) was the most frequent perinatal risk factor followed by fetal distress 27 (18) and PIH 21 (14%).Conclusions: Newborns with thick MSAF were more likely to develop MAS and thick MSAF and low APGAR at 1 min were associated with high risk of development of MAS. Passage of thick meconium was significantly associated with severe birth asphyxia and carried a bad prognosis with increased risk of development of meconium aspiration syndrome and hypoxic ischaemic encephalopathy.


2019 ◽  
Vol 6 (2) ◽  
pp. 491 ◽  
Author(s):  
Shilpasri Y. M. ◽  
Madhurya B.

Background: Meconium stained amniotic fluid has been considered a sign of fetal distress and associated with poor fetal outcome, but others considered meconium passage by fetus is physiological phenomena and produce environmental hazards to fetus before birth. Such magnitude of different opinion was the object behind taking up of this study and aim was to find out incidence and effect of meconium in terms of morbidity and mortality.Methods: Two hundred babies born with meconium stained amniotic fluid considering the inclusion and exclusion criteria from December 2012 to June 2013 in the Department of Paediatrics, Cheluvamba hospital attached to Mysore Medical College and Research Institute, Mysore. Fetal monitoring, mode of delivery, Apgar score, birth weight, resuscitation of baby are noted. All babies followed-up up to 1st week of neonatal life.Results: In present study 200 babies born through meconium stained amniotic fluid was randomly selected-thin 37% and thick 63%. Major complications like birth asphyxia, meconium aspiration syndrome, early neonatal death seen in 5.5% (11 cases), morbidity in 37%, 12.5% in thin and 24.5% in thick MSAF. Causes of death were meconium aspiration syndrome in 3 cases, sepsis in 1 case, pneumonia in 1 case and birth asphyxia in 6 cases.Conclusions: Immediate airway management, need for suction and intubation should be guided by state of newborn rather than presence of meconium. Timely diagnosis and management of meconium stained amniotic fluid may improve fetal outcome. From present study authors conclude that MSAF adversely affect fetal outcome mostly by thick meconium.


2018 ◽  
Vol 5 (2) ◽  
pp. 552
Author(s):  
Sushant Kumar ◽  
Minni Rani Akhouri

Background: Meconium-stained amniotic fluid (MSAF) accounts for approximately 10-15% of live births and Meconium aspiration syndrome occurs in 5% among infants born through MSAF. The purpose of this study was to evaluate the outcome in neonates with meconium aspiration syndrome with regard to thin and thick meconium. Methods: A prospective cohort study of inborn neonates was done from April 2016 to August 2017 admitted in neonatal intensive care unit, Department of Paediatrics and Neonatology, RIMS, Ranchi after obtaining written informed consent from the parents or guardian and diagnosis of MAS was made depending on the clinical criteria and its clinical outcome was observed. MAS babies were studied on the basis of thin and thick meconium stained amniotic fluid.Results: The mean birth weight in thin meconium was 2760±394. The mean APGAR score in thin meconium at 1 minute (3.57±1.01) and 5 minutes (5.57±1.62) was significantly more than thick meconium. The mode of delivery in thin meconium was commonly by cesarean section (76.9%). There was need for resuscitation in 46.1% in thin meconium neonates which was significantly higher than neonates born with thick meconium 6.6% (P value 0.000). The most common complication in thin meconium was birth asphyxia (69.2%), followed by ARF and septicemia. Death was significantly higher in neonates born with thin meconium (69.2%)as compared to thick (20%) with P value of 0.000Conclusions: Amniotic fluid with thin meconium may cause more respiratory and other complications in neonates than amniotic fluid with thick meconium. Hence proper diagnosis and timely intervention can reduce the morbidity and mortality in neonates with meconium aspiration syndrome.


Sign in / Sign up

Export Citation Format

Share Document