A Study on the Characteristic Searching between Output-Output Balance and Final Demand-Final Output Balance Equations

2021 ◽  
Vol 40 (1) ◽  
pp. 151-189
Author(s):  
Ho Un Gim
1994 ◽  
Vol 144 ◽  
pp. 315-321 ◽  
Author(s):  
M. G. Rovira ◽  
J. M. Fontenla ◽  
J.-C. Vial ◽  
P. Gouttebroze

AbstractWe have improved previous model calculations of the prominence-corona transition region including the effect of the ambipolar diffusion in the statistical equilibrium and energy balance equations. We show its influence on the different parameters that characterize the resulting prominence theoretical structure. We take into account the effect of the partial frequency redistribution (PRD) in the line profiles and total intensities calculations.


2020 ◽  
Vol 2 (1) ◽  
pp. 19-24
Author(s):  
Sakhr Mohammed Sultan ◽  
Chih Ping Tso ◽  
Ervina Efzan Mohd Noor ◽  
Fadhel Mustafa Ibrahim ◽  
Saqaff Ahmed Alkaff

Photovoltaic Thermal Solar Collector (PVT) is a hybrid technology used to produce electricity and heat simultaneously. Current enhancements in PVT are to increase the electrical and thermal efficiencies. Many PVT factors such as type of absorber, thermal conductivity, type of PV module and operating conditions are important parameters that can control the PVT performance. In this paper, an analytical model, using energy balance equations, is studied for PVT with an improved parallel flow absorber. The performance is calculated for a typical sunny weather in Malaysia. It was found that the maximum electrical and thermal efficiencies are 12.9 % and 62.6 %, respectively. The maximum outlet water temperature is 59 oC.


1980 ◽  
Vol 19 (3) ◽  
pp. 247-249
Author(s):  
A. R. Kemal

Input -output analysis is being widely used in developing countries for planning purposes. For a given level of final demand, input-output analysis allows us to project the required level of gross output to ensure consistency of plan. These projections are made on the assumption that the existing production structure is optimal and it implies that an increase in demand will be met through the expansion of domestic output even when it can be satisfied through an increase in imports. On the other hand, according to the semi-input-output method, we do not have to increase the output of international sectors in order to meet the increase in demand because the level and composition of these activities should be determined by comparative- cost considerations. These are the only national sectors in which output must increase in order to avoid shortage. The semi-input -output method has been such a useful and important contribution, yet, regrettably, its influence on the planning models had been rather limited.


Author(s):  
Vladimir Lantsov ◽  
A. Papulina

The new algorithm of solving harmonic balance equations which used in electronic CAD systems is presented. The new algorithm is based on implementation to harmonic balance equations the ideas of model order reduction methods. This algorithm allows significantly reduce the size of memory for storing of model equations and reduce of computational costs.


2012 ◽  
Vol 7 (4) ◽  
Author(s):  
K. Harriden

Generally regarded as social phenomena, this paper regards slum urbanisation as an environmental actor. Specifically, how slum developments modify hydrogeomorphological processes motivates this research. Using the Bang Pakong River, eastern Thailand, as a case study, a literature review was conducted. The literature reviewed indicated changes in physical processes such as channel bank stability, water quality, flow regimes and the hydrological balance equations can occur with slum development. Given the importance of channel banks as the physical basis of many slum sites, this paper focuses on the possible changes to channel bank storage in the Bang Pakong River following slum urbanisation. The research highlights possible changes to channel bank storage processes, notably decreased storage recharge rates; increased anthropogenic extraction; and probable water quality deterioration. Deeper scientific understanding of how river processes are affected by specific forms of urban development can contribute to better management of both informal urban settlements and rivers.


2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Satyender Singh ◽  
Prashant Dhiman

Thermal performance of a single-pass single-glass cover solar air heater consisting of semicircular absorber plate finned with rectangular longitudinal fins is investigated. The analysis is carried out for different hydraulic diameters, which were obtained by varying the diameter of the duct from 0.3–0.5 m. One to five numbers of fins are considered. Reynolds number ranges from 1600–4300. Analytical solutions for energy balance equations of different elements and duct flow of the solar air heater are presented; results are compared with finite-volume methodology based numerical solutions obtained from ansys fluent commercial software, and a fairly good agreement is achieved. Moreover, analysis is extended to check the effect of double-glass cover and the recycle of the exiting air. Results revealed that the use of double-glass cover and recycle operation improves the thermal performance of solar air heater.


Sign in / Sign up

Export Citation Format

Share Document