Design and production of a demountable modular infusion pump

Author(s):  
Zehra Gok Metin

The study aimed to produce a new pump with different and improved features and included three phases. In phase one, we collected the views of 40 nurses on pumps available in the market. In phase two, a pump was designed and a prototype was produced. In phase three, 10 nurses used and evaluated the prototype. The prototype combined three intravenous infusion pumps and one enteral pump in a single machine. Nurses assessed the prototype in a practice laboratory. All nurses found prototype very adequate with respect to carrying and installing. 90% of nurses found the prototype very adequate and practical in general. Moreover, the majority (80%) stated that the prototype produced less noise than the available pumps in the market.  Keywords: Nurse; design; infusion pump; enteral nutrition; patient safety.   

2019 ◽  
Vol 7 ◽  
pp. 205031211882262
Author(s):  
Alexander F van der Sluijs ◽  
Eline R van Slobbe-Bijlsma ◽  
Astrid Goossens ◽  
Alexander PJ Vlaar ◽  
Dave A Dongelmans

Background: Medication errors occur frequently and may potentially harm patients. Administering medication with infusion pumps carries specific risks, which lead to incidents that affect patient safety. Objective: Since previous attempts to reduce medication errors with infusion pumps failed in our intensive care unit, we chose the Lean approach to accomplish a 50% reduction of administration errors in 6 months. Besides improving quality of care and patient safety, we wanted to determine the effectiveness of Lean in healthcare. Methods: We conducted a before-and-after observational study. After baseline measurement, a value stream map (a detailed process description, used in Lean) was made to identify important underlying causes of medication errors. These causes were discussed with intensive care unit staff during frequent stand-up sessions, resulting in small improvement cycles and bottom-up defined improvement measures. Pre-intervention and post-intervention measurements were performed to determine the impact of the improvement measures. Infusion pump syringes and related administration errors were measured during unannounced sequential audits. Results: Including the baseline measurement, 1748 syringes were examined. The percentage of errors concerning the administration of medication by infusion pumps decreased from 17.7% (95% confidence interval, 13.7–22.4; 55 errors in 310 syringes) to 2.3% (95% confidence interval, 1–4.6; 7 errors in 307 syringes) in 18 months (p < 0.0001). Conclusion and Relevance: The Lean approach proved to be helpful in reducing errors in the administration of medication with infusion pumps in a high complex intensive care environment.


Author(s):  
Roger Gagnon ◽  
Jason Laberge ◽  
Allison Lamsdale ◽  
Jonathan Histon ◽  
Carl Hudson ◽  
...  

Author(s):  
Tosha B. Wetterneck ◽  
Pascale Carayon ◽  
Folasade Sobande ◽  
Ann Schoofs Hundt

2013 ◽  
Vol 9 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Kate Bak ◽  
Eric Gutierrez ◽  
Elizabeth Lockhart ◽  
Michael Sharpe ◽  
Esther Green ◽  
...  

The varied results of radiation exposure on infusion devices suggest that additional testing should be carried out to determine the limits of dose exposure, and to raise awareness around this patient safety issue.


Nutrients ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 82
Author(s):  
Magdalena Hoffmann ◽  
Christine Maria Schwarz ◽  
Stefan Fürst ◽  
Christina Starchl ◽  
Elisabeth Lobmeyr ◽  
...  

Critically ill patients in the intensive care unit (ICU) have a high risk of developing malnutrition, and this is associated with poorer clinical outcomes. In clinical practice, nutrition, including enteral nutrition (EN), is often not prioritized. Resulting from this, risks and safety issues for patients and healthcare professionals can emerge. The aim of this literature review, inspired by the Rapid Review Guidebook by Dobbins, 2017, was to identify risks and safety issues for patient safety in the management of EN in critically ill patients in the ICU. Three databases were used to identify studies between 2009 and 2020. We assessed 3495 studies for eligibility and included 62 in our narrative synthesis. Several risks and problems were identified: No use of clinical assessment or screening nutrition assessment, inadequate tube management, missing energy target, missing a nutritionist, bad hygiene and handling, wrong time management and speed, nutritional interruptions, wrong body position, gastrointestinal complication and infections, missing or not using guidelines, understaffing, and lack of education. Raising awareness of these risks is a central aspect in patient safety in ICU. Clinical experts can use a checklist with 12 identified top risks and the recommendations drawn up to carry out their own risk analysis in clinical practice.


2019 ◽  
Vol 104 (7) ◽  
pp. e2.2-e2
Author(s):  
Nurain Binti Abu Hasan ◽  
Andrew Wignell

AimInfusion pumps are commonly used to administer medicines by intravenous infusion. Traditionally, pumps are programmed by simply entering the required number of millilitres (mL) per hour, and there has been no mechanism whereby the pump can alert the operator to a programming error e.g. the wrong mL/hour rate being entered.More recently, ‘smart’ infusion pumps have become available which have in-built drug libraries. For each drug, defined dosing limits are set. Users are required to reconfirm the selected infusion rate when ‘soft’ limits are overridden and the infusion cannot be commenced if ‘hard’ limits are exceeded. Soft and hard limits can also be set for the administration of boluses from continuous infusions. This study aimed to evaluate the introduction of smart syringe pumps into a UK PICU by objective assessment of compliance with drug library use, and by obtaining direct feedback from nursing staff.MethodsData was collected over a 4 week period, immediately following the introduction of new Alaris CC smart syringe pumps. Objective assessment of drug library use utilised a piloted data collection form. One form was completed for each infusion running at the time of daily data collection. The prescription, syringe label, and programmed pump parameters were checked for each infusion and any discrepancies noted. Where the drug library was not being used, reasons for non-use were recorded. Nursing views on the benefits and potential risks of the new smart syringe pumps were determined through individual and group interviews, each following the same pre-prepared format.Results79 individual drug infusions were observed. 4 (5%) were being given without using the drug library, i.e. just in terms of mL/hour; in all cases, the explanation was the fact that the drug was not included in the library. 73 (92%) of the infusions observed were continuous, the remainder intermittent. 13 nurses were interviewed: the unanimous view was that the new smart pumps improved patient safety. One nurse described a situation where the smart pump had prevented a 10-fold paracetamol overdose. Many nurses commented that pre-defined sedation boluses were a definite patient-safety benefit, both in terms of preventing incorrect dosing or the bolusing of the wrong drug. Nurses, in general, felt that the safety benefits of smart pumps applied equally to intermittent and continuous infusions. Nurses found the drug libraries easy to use, and whilst infusion set-up may take marginally longer with the drug libraries than without, this was offset by patient safety benefits. It was noted that the longer time taken to programme the pumps may diminish as familiarity increases. A small number of minor issues with the drug library were identified through nursing feedback, though none of them were patient-safety critical. This has allowed the drug library to be modified before the same pumps are also introduced to general wards across the Children’s Hospital.ConclusionThe drug libraries in the new smart syringe pumps were being routinely and correctly used throughout the study period. Nursing staff had embraced the new technology, seeing clear patient safety benefits.


2020 ◽  
Vol 77 (15) ◽  
pp. 1231-1236
Author(s):  
Roy Joseph ◽  
Sang Weon Lee ◽  
Scott V Anderson ◽  
Matthew J Morrisette

Abstract Purpose To describe the benefits of smart infusion pump interoperability with an electronic medical record (EMR) system in an adult intensive care unit (ICU) setting. Summary In order to assess the impact of smart infusion pump and EMR interoperability, we observed whether there were changes in the frequency of electronic medication administration record (eMAR) documentation of dose titrations in epinephrine and norepinephrine infusions in the ICU setting. As a secondary endpoint, we examined whether smart pump/EMR interoperability had any impact on the rate of alerts triggered by the dose-error reduction software. Pharmacist satisfaction was measured to determine the impact of smart pump/EMR interoperability on pharmacist workflow. In the preimplementation phase, there were a total of 2,503 administrations of epinephrine and norepinephrine; 13,299 rate changes were documented, for an average of 5.31 documented rate changes per administration. With smart pump interoperability, a total of 13,024 rate changes were documented in association with 1,401 administrations, for an average of 9.29 documented rate changes per administration (a 74.9% increase). A total of 1,526 dose alerts were triggered in association with 76,145 infusions in the preimplementation phase; there were 820 dose alerts associated with 48,758 autoprogammed infusions in the postimplementation phase (absolute difference, –0.32%). ICU pharmacists largely agreed (75% of survey respondents) that the technology provided incremental value in providing patient care. Conclusion Interoperability between the smart pump and EMR systems proved beneficial in the administration and monitoring of continuous infusions in the ICU setting. Additionally, ICU pharmacists may be positively impacted by improved clinical data accuracy and operational efficiency.


1987 ◽  
Vol 15 (2) ◽  
pp. 217-228 ◽  
Author(s):  
W. B. Runciman ◽  
A. H. Ilsley ◽  
A. J. Rutten ◽  
D. Baker ◽  
R. R. L. Fronsko

The accuracy, safety, reliability and cost of use of 35 intravenous infusion pumps and 3 flow controllers were assessed. When infusing saline 11 out of 17 syringe pumps, 3 out of 5 peristaltic pumps, 1 out of 2 roller pumps and all 14 cassette pumps tested were accurate to within 5% over their full ranges of operation. There was no significant change in the performance of any of the pumps tested when saline was infused through a standard resistance, except in the cases of the 3 flow controllers which were unable to infuse at all against the resistance. When 50% dextrose was infused, delivery by two peristaltic pumps was reduced by 23 and 38%. No pump cut out or alarmed at pressures of up to 200 mmHg and 21 pumps continued to infuse against pressures of 750 mmHg or greater. Surges of up to 0.5 ml occurred after release of an outlet obstruction. One device was fitted with a variable high pressure alarm. This device could also measure pressure in the infused vessel and was found to be accurate for measurements of central venous pressure. The cost of consumables for a single use for syringe pumps ranges from A$2 to $5, for peristaltic and roller pumps from A$1 to $10, and for cassette pumps from A$7 to $12, with an additional A$2 for a burette. Accurate delivery of intravenous fluids and drugs is available but is expensive and requires the operator to be specially trained. No simple, cheap, accurate device is yet available.


Science ◽  
1939 ◽  
Vol 89 (2299) ◽  
pp. 63-64
Author(s):  
G. Katz

1979 ◽  
Vol 137 (2) ◽  
pp. 274-275 ◽  
Author(s):  
Charles M. Abernathy ◽  
T.C. Dickinson

Sign in / Sign up

Export Citation Format

Share Document