Real-Time and Time-Lapse LWD Images for Geosteering and Formation Evaluation

2002 ◽  
Vol 54 (06) ◽  
pp. 49-49 ◽  
Author(s):  
Dennis Denney
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sherif M. Hanafy ◽  
Hussein Hoteit ◽  
Jing Li ◽  
Gerard T. Schuster

AbstractResults are presented for real-time seismic imaging of subsurface fluid flow by parsimonious refraction and surface-wave interferometry. Each subsurface velocity image inverted from time-lapse seismic data only requires several minutes of recording time, which is less than the time-scale of the fluid-induced changes in the rock properties. In this sense this is real-time imaging. The images are P-velocity tomograms inverted from the first-arrival times and the S-velocity tomograms inverted from dispersion curves. Compared to conventional seismic imaging, parsimonious interferometry reduces the recording time and increases the temporal resolution of time-lapse seismic images by more than an order-of-magnitude. In our seismic experiment, we recorded 90 sparse data sets over 4.5 h while injecting 12-tons of water into a sand dune. Results show that the percolation of water is mostly along layered boundaries down to a depth of a few meters, which is consistent with our 3D computational fluid flow simulations and laboratory experiments. The significance of parsimonious interferometry is that it provides more than an order-of-magnitude increase of temporal resolution in time-lapse seismic imaging. We believe that real-time seismic imaging will have important applications for non-destructive characterization in environmental, biomedical, and subsurface imaging.


2021 ◽  
Vol 11 (7) ◽  
pp. 3122
Author(s):  
Srujana Neelam ◽  
Audrey Lee ◽  
Michael A. Lane ◽  
Ceasar Udave ◽  
Howard G. Levine ◽  
...  

Since opportunities for spaceflight experiments are scarce, ground-based microgravity simulation devices (MSDs) offer accessible and economical alternatives for gravitational biology studies. Among the MSDs, the random positioning machine (RPM) provides simulated microgravity conditions on the ground by randomizing rotating biological samples in two axes to distribute the Earth’s gravity vector in all directions over time. Real-time microscopy and image acquisition during microgravity simulation are of particular interest to enable the study of how basic cell functions, such as division, migration, and proliferation, progress under altered gravity conditions. However, these capabilities have been difficult to implement due to the constantly moving frames of the RPM as well as mechanical noise. Therefore, we developed an image acquisition module that can be mounted on an RPM to capture live images over time while the specimen is in the simulated microgravity (SMG) environment. This module integrates a digital microscope with a magnification range of 20× to 700×, a high-speed data transmission adaptor for the wireless streaming of time-lapse images, and a backlight illuminator to view the sample under brightfield and darkfield modes. With this module, we successfully demonstrated the real-time imaging of human cells cultured on an RPM in brightfield, lasting up to 80 h, and also visualized them in green fluorescent channel. This module was successful in monitoring cell morphology and in quantifying the rate of cell division, cell migration, and wound healing in SMG. It can be easily modified to study the response of other biological specimens to SMG.


2003 ◽  
Vol 1855 (1) ◽  
pp. 97-104 ◽  
Author(s):  
Christopher Strong ◽  
Scott Lowry ◽  
Peter McCarthy

An innovative application of time-lapse video recording is used to assist in an evaluation of a highway safety improvement. The improvement is an icy-curve warning system near Fredonyer Summit in northern California that activates real-time motorist warnings via extinguishable message signs, based on weather readings collected from road weather information systems. A measure of effectiveness is whether motorist speed is reduced as a result of real-time warnings to drivers. Why indirect speed measurement with video was preferred over radar for this case is discussed, as is how specific methodological issues related to the custom-built equipment, including camera location and orientation, distance benchmarking, and data collection and reduction. Theoretical and empirical accuracy measurements show that the video surveillance trailers yield results comparable to radar and, hence, would be applicable for studies in which speed change is measured. Because this particular technology had not been used previously, several lessons are documented that may help determine where and how similar equipment may be optimally used in future studies.


2022 ◽  
Author(s):  
Michael G. Wuo ◽  
Charles L Dulberger ◽  
Robert A. Brown ◽  
Alexander Sturm ◽  
Eveline Ultee ◽  
...  

The current understanding of mycobacterial cell envelope remodeling in response to antibiotics is limited. Chemical tools that report on phenotypic changes with minimal cell wall perturbation are critical to gaining insight into this time-dependent phenomenon. Herein we describe a fluorogenic chemical probe that reports on mycobacterial cell envelope assembly in real time. We used time-lapse microscopy to reveal distinct spatial and temporal changes in the mycobacterial membrane upon treatment with frontline antibiotics. Differential antibiotic treatment elicited unique cellular phenotypes, providing a platform for monitoring cell envelope construction and remodeling responses simultaneously. Analysis of the imaging data indicates a role for antibiotic-derived outer membrane vesicles in immune modulation.


2021 ◽  
Author(s):  
Muhamad Aizat Kamaruddin ◽  
Ayham Ashqar ◽  
Muhammad Haniff Suhaimi ◽  
Fairus Azwardy Salleh

Abstract Uncertainties in fluid typing and contacts within Sarawak Offshore brown field required a real time decision. To enhance reservoir fluid characterisation and confirm reservoir connectivity prior to well final total depth (TD). Fluid typing while drilling was selected to assure the completion strategy and ascertain the fluvial reservoir petrophysical interpretation. Benefiting from low invasion, Logging While Drilling (LWD) sampling fitted with state of ART advanced spectroscopy sensors were deployed. Pressures and samples were collected. The well was drilled using synthetic base mud. Conventional logging while drilling tool string in addition to sampling tool that is equipped with advanced sensor technology were deployed. While drilling real time formation evaluation allowed selecting the zones of interest, while fluid typing was confirmed using continually monitored fluids pump out via multiple advanced sensors, contamination, and reservoir fluid properties were assessed while pumping. Pressure and sampling were performed in drilling mode to minimise reservoir damage, and optimise rig time, additionally sampling while drilling was performed under circulation conditions. Pressures were collected first followed by sampling. High success in collecting pressure points with a reliable fluid gradient that indicated a virgin reservoir allowed the selection of best completion strategy without jeopardising reserves, and reduced rig time. Total of seven samples from 3 different reservoirs, four oil, and three formation water. High quality samples were collected. The dynamic formation evaluation supported by while drilling sampling confirmed the reservoir fluid type and successfully discovered 39ft of oil net pay. Reservoir was completed as an oil producer. The Optical spectroscopy measurements allowed in situ fluid typing for the quick decision making. The use of advanced optical sensors allowed the sample collection and gave initial assessment on reservoir fluids properties, as a result cost saving due to eliminating the need for additional Drill Stem Test (DST) run to confirm the fluid type. Sample and formation pressures has confirmed reservoir lateral continuity in the vicinity of the field. The reservoir developed as thick and blocky sandstone. Collected sample confirmed the low contamination levels. Continuous circulation mitigated sticking and potential well-control risks. This is the first time in surrounding area, advanced optical sensors are used to aid LWD sampling and to finalize the fluid identification. The innovative technology allowed the collection of low contamination. The real-time in-situ fluid analysis measurement allowed critical decisions to be made real time, consequently reducing rig downtime. Reliable analysis of fluid type identification removed the need for additional run/service like DST etc.


Sign in / Sign up

Export Citation Format

Share Document