Development of a High-Boost, High-Power, Ultradeep Subsea Twin Screw Multiphase Pump System

Author(s):  
Adrian Paul Williams ◽  
Bob Urban ◽  
Jonah Margulis
Author(s):  
Ove F. Jahnsen ◽  
John Yardley ◽  
Geoff High ◽  
Brede Thorkilsen

Abstract This paper describes Kvaerner’s prototype subsea multiphase pump system and the DEMO 2000 development program (current test completion date 2nd Q2001). Reference is also made to service proven sub-systems, components and subsea expertise incorporated into the pump module and system design. Availability and reliability consideration together with novel plans for the future is presented. The Subsea Multiphase Pump and motor are packaged into a modular system solution that is readily adaptable to template and manifold configurations and maximises the use of existing qualified components and sub-systems. A guidewireless system is adopted and Kvaerner’s design ensures self-alignment upon installation at simple flowbase interfaces, making it ideal for deepwater applications. Due to the individual 40 tonne weight, and moonpool dimensions, of both flow base and pump module, light monohull vessels can be utilised to execute installation and retrieval. The pump unit is Bornemann twin-screw design, service proven and modified for subsea use up to 2000-meter water depth, driven by an oil-filled Loher electric motor that provides efficient power with corresponding low weight. Some main pump features are flexible operation covering all gas-liquid ratios together with tolerance for slug flow and some sand. Of particular importance, compared to centrifugal pump designs, the twin-screw volumetric arrangement is able to maintain the pressure boost specification independent of gas content at the pump inlet, and without an upstream mixing tank.


2004 ◽  
Vol 3 (2) ◽  
Author(s):  
C. Y. Nakashima ◽  
S. Oliveira Jr. ◽  
E. F. Caetano

This paper presents a methodology for an exergetic comparison between two artificial lift systems: a gas lift and a twin-screw multiphase pump system, and a standalone offshore platform. A software (Hysys.Process v2.1) was used to simulate an offshore platform with the artificial lift methods and calculate all properties (including exergy) of the material and energy streams. The twin-screw multiphase pump behavior was simulated with a thermodynamic model developed recently (NAKASHIMA (2000) and NAKASHIMA, OLIVEIRA and CAETANO (2002)). The operational conditions of the PETROBRAS 7- MRL-72D-RJS well operating with cited systems were predicted by an internal study conducted in PETROBRAS (BARUZZI et al. (2001a) and partially published in BARUZZI et al. (2001b)). The comparisons cover the range of 2000 to 2020, the same range adopted in the study. Results show that in general the production costs are lower when the multiphase pump is used. The main advantages of this method over the gas lift is the absence of material (gas) recycle and a better energy management.


2004 ◽  
Vol 3 (2) ◽  
pp. 107 ◽  
Author(s):  
C. Y. Nakashima ◽  
S. Oliveira Jr. ◽  
E. F. Caetano

This paper presents a methodology for an exergetic comparison between two artificial lift systems: a gas lift and a twin-screw multiphase pump system, and a standalone offshore platform. A software (Hysys.Process v2.1) was used to simulate an offshore platform with the artificial lift methods and calculate all properties (including exergy) of the material and energy streams. The twin-screw multiphase pump behavior was simulated with a thermodynamic model developed recently (NAKASHIMA (2000) and NAKASHIMA, OLIVEIRA and CAETANO (2002)). The operational conditions of the PETROBRAS 7- MRL-72D-RJS well operating with cited systems were predicted by an internal study conducted in PETROBRAS (BARUZZI et al. (2001a) and partially published in BARUZZI et al. (2001b)). The comparisons cover the range of 2000 to 2020, the same range adopted in the study. Results show that in general the production costs are lower when the multiphase pump is used. The main advantages of this method over the gas lift is the absence of material (gas) recycle and a better energy management.


2021 ◽  
Vol 14 (4) ◽  
pp. 335-344
Author(s):  
Shuaihui Sun ◽  
Pengbo Wu ◽  
Pengcheng Guo ◽  
Guangzhi Yi ◽  
Ahmed Kovacevic

Author(s):  
Gerald Morrison ◽  
Michael Glier ◽  
Shankar Narayanan ◽  
Jun Xu ◽  
Stuart Scott ◽  
...  

A Progressive Cavity Pump (PCP) was evaluated for use as a multiphase pump. The pump is a 576 gpm, constant wall thickness PCP operating with an air/water mixture. Thermocouples were installed along the length of the pump to monitor the elastomer temperature to determine when excessive temperatures were present. Inlet pressures of 15, 30, and 45 psig were considered with pressure rises of 30, 60, 90, 120, and 150 psig. The GVF’s considered were 20, 40, 60, 90, and 98%. It was determined that with the water and air mixture, 98% was the maximum GVF at which the pump could operate continuously. The volumetric efficiency, pump effectiveness, and mechanical efficiency were calculated. The temperature rise across the pump was small, so an isothermal flow was assumed. The PCP investigated has a steel rotor and an elastomer stator that were manufactured with an interference fit. This resulted in volumetric efficiencies above 95% for all test conditions at full speed. This interference fit produces a significant drag on the rotor which is relatively constant at a given speed over the entire operating range considered. This results in the mechanical efficiency being low, 15 to 20%, for ΔP = 30 psig but approaching 60% at ΔP = 150 psi for 0% GVF. The mechanical efficiency decreased with increasing GVF to a low of 28% at ΔP = 150 psi for 98% GVF. The GVF specified here is the actual GVF passing through the pump. If a liquid recirculation system were added to the pump reducing the GVF in the pump, higher efficiencies and the ability to operate at 100% GVF for the process fluid entering the pump system can be obtained.


Author(s):  
Joon-Hyung Kim ◽  
Him-Chan Lee ◽  
Joon-Yong Yoon ◽  
Kyoung-Yong Lee ◽  
Yong-Kab Lee ◽  
...  

The crude oil produced from well contains a mixture of oil, gas and water. The existing pump system that uses a single phase pump requires a separator to separate the crude oil. Changing from a single phase pump to a multiphase pump significantly reduces costs because a multiphase pump does not require a separator. Therefore, most wells currently being developed apply the multiphase pump system. In this study, a multiphase pump was designed using a multi objective optimization technique. To conduct research, a base model was chosen and its performance was evaluated through numerical analysis. The design variables and variable ranges were set for the impeller and the diffuser. Based on the selected variables, experiment sets were produced. The experiment sets were also evaluated for their performance using numerical analysis. Based on the performance evaluation results of each experiment set, the optimization model for a multiphase pump was derived using Response Surface Method (RSM). In addition, each model’s performance for multiphase flow was also evaluated according to changes in Gas Volume Fraction (GVF) using multiphase numerical analysis. Furthermore, the internal flow characteristics of each model were analyzed.


2013 ◽  
Author(s):  
Rayid S. Al-Anazi ◽  
Shaleh M. Al-Ajmi ◽  
Esshaq M. Al-Hasan ◽  
Mohammed H. Al-Buali

2000 ◽  
Vol 005.2 (0) ◽  
pp. 69-70
Author(s):  
Akinori FURUKAWA ◽  
Hisasada TAKAHARA ◽  
Ken MATSUDA ◽  
Hidetsugu ODA

Sign in / Sign up

Export Citation Format

Share Document