scholarly journals Clinical Validation and Treatment Plan Evaluation Based on Auto-Delineation of the Clinical Target Volume for Prostate Cancer Radiotherapy

Author(s):  
Jing Shen ◽  
Yinjie TAO ◽  
Hui GUAN ◽  
Hongnan ZHEN ◽  
Lei HE ◽  
...  

Abstract Purpose Clinical target volumes (CTV) and organs at risk (OAR) could be auto-contoured to save workload. The goal of this study was to assess a convolutional neural network (CNN) for totally automatic and accurate CTV and OAR in prostate cancer, while also comparing anticipated treatment plans based on auto-contouring CTV to clinical plans. Methods From January 2013 to January 2019, 217 computed tomography (CT) scans of patients with locally advanced prostate cancer treated at our hospital were collected and analyzed. CTV and OAR were delineated with a deep learning based method, which named CUNet. The performance of this strategy was evaluated using the mean Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (95HD), and subjective evaluation. Treatment plans were graded using predetermined evaluation criteria, and % errors for clinical doses to the planned target volume (PTV) and organs at risk(OARs) were calculated. Results The defined CTVs had mean DSC and 95HD values of 0.84 and 5.04 mm, respectively. For one patient's CT scans, the average delineation time was less than 15 seconds. When CTV outlines from CUNetwere blindly chosen and compared to GT, the overall positive rate in clinicians A and B was 53.15% vs 46.85%, and 54.05% vs 45.95%, respectively (P>0.05), demonstrating that our deep machine learning model performed as good as or better than human demarcation Furthermore, 8 testing patients were chosen at random to design the predicted plan based on the auto-courtoring CTV and OAR, demonstrating acceptable agreement with the clinical plan: average absolute dose differences of D2, D50, D98, Dmean for PTV are within 0.74%, and average absolute volume differences of V45, V50 for OARs are within 3.4%. Without statistical significance (p>0.05), the projected findings are comparable to clinical truth. Conclusion The experimental results show that the CTV and OARs defined by CUNet for prostate cancer were quite close to the ground reality.CUNet has the potential to cut radiation oncologists' contouring time in half. When compared to clinical plans, the differences between estimated doses to CTV and OAR based on auto-courtoring were small, with no statistical significance, indicating that treatment planning for prostate cancer based on auto-courtoring has potential.

2014 ◽  
Vol 32 (3_suppl) ◽  
pp. 369-369
Author(s):  
Jerry Monroe Slater ◽  
Ted Chen-Tai Ling ◽  
Prashanth Nookala ◽  
Rachel Mifflin ◽  
Roger Grove ◽  
...  

369 Background: The purpose of this study is to investigate dose distributions of proton and intensity-modulated radiation therapy (IMRT) photon treatment plans in patients with resected pancreatic adenocarcinoma, focusing specifically on dose reduction to the kidney, liver, and small bowel as organs at risk. Methods: Ten patients with pancreatic head adenocarcinoma underwent Whipple procedure between 2010 and 2013 were included in this study. Most of the patients had locally advanced disease (T3-4N1). All patients were simulated with contrast-enhanced CT imaging. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10 mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15 mm. A dose of 50.4 Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 95% isodose coverage of at least 95% of the PTV. Dose-volume histograms, conformity index (CI), uniformity index (UI), homogeneity index (HI), were calculated and analyzed in order to compare plans between the two modalities. The OAR being evaluated in this study are the kidneys, liver, small bowel, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The proton plans resulted in a lower mean kidney dose (3.17 Gy vs. 9.59 Gy, p=0.039), a lower dose delivered to 1/3 of the liver, D1/3, (0.25 Gy vs. 4.56 Gy, p=0.003), and a lower mean liver dose (1.83 Gy vs. 5.24 Gy, p=0.021). See table for a summary of the results. Conclusions: For patients receiving postoperative radiotherapy for pancreatic cancer, the proton plans are technically feasible and dosimetrically appealing with superior organ at risk sparing compared to IMRT photon treatment plans.[Table: see text]


2014 ◽  
Vol 190 (3) ◽  
pp. 310-316 ◽  
Author(s):  
P. Hüttenrauch ◽  
M. Witt ◽  
D. Wolff ◽  
S. Bosold ◽  
R. Engenhart-Cabillic ◽  
...  

2011 ◽  
Vol 29 (4_suppl) ◽  
pp. 316-316
Author(s):  
S. F. Petit ◽  
B. Wu ◽  
M. Kazhdan ◽  
A. Dekker ◽  
P. Simari ◽  
...  

316 Background: Due to the low dose tolerance of the organs at risk (OARs) in the abdomen the tumor dose for pancreatic cancer patient is restricted to 50-60 Gy in 1.8-2.0 Gy fractions when combined with chemotherapy. The goal of this study was to develop a system that can determine the minimal radiation dose to the OARs of each individual patient that is achievable while maintaining adequate tumor coverage. This could guide treatment planners to spare the OARs to the fullest extent. When the minimal doses to the OAR are achieved, the total plan can be upscaled until the normal tissue dose constraints are met, allowing for an increase in tumor dose without increased normal tissue toxicity. Methods: The minimal achievable dose to the OARs depends on its proximity to the planning target volume (PTV). The overlap volume histogram (OVH) was used to describe the spatial relation of each OAR to the PTV. A database of 33 patients, treated with IMRT, was queried to find the lowest achieved dose to an organ for any of the prior patients with less favorable PTV-OAR configurations than the current patient. This minimal dose must also be achievable for the OAR of the new patient. For 25 randomly chosen patients the lowest achievable dose to the liver and kidneys was predicted this way. Then the patients were replanned to verify if this dose could be achieved. The new plans were compared to the original clinical plans. Results: After replanning the predicted achievable dose to the liver was realized within 1 and 2 Gy for more than 86% and 96% of the patients respectively. For the kidneys these numbers were 83% and 96%. The average improvement in terms of mean dose was 1.4 Gy (range 0 – 4.6 Gy) for the liver and 1.7 Gy (range 0 – 6.3 Gy) for the kidneys. This would have allowed an increase in PTV dose of on average 5 Gy (range 0-13 Gy) based on the liver and 8.5 Gy (range 0-38 Gy) based on the kidneys compared to the original plan, without an increase in dose to the bowel, cord, and stomach. Conclusions: The lowest achievable dose to the OARs could accurately be predicted for pancreatic cancer patients within seconds. This can guide dosimetrists to spare the OARs or increase the PTV dose by 5 Gy without increased toxicity. [Table: see text]


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Gerhard Pollul ◽  
Tilman Bostel ◽  
Sascha Grossmann ◽  
Sati Akbaba ◽  
Heiko Karle ◽  
...  

Abstract Background This study aimed to contrast four different irradiation methods for pediatric medulloblastoma tumors in a dosimetric comparison regarding planning target volume (PTV) coverage and sparing of organs at risk (OARs). Methods In sum 24 treatment plans for 6 pediatric patients were realized. Besides the clinical standard of a 3D-conformal radiotherapy (3D-CRT) treatment plan taken as a reference, volumetric modulated arc therapy (VMAT) treatment plans (“VMAT_AVD” vs. “noAVD” vs. “FullArc”) were optimized and calculated for each patient. For the thoracic and abdominal region, the short partial-arc VMAT_AVD technique uses an arc setup with reduced arc-length by 100°, using posterior and lateral beam entries. The noAVD uses a half 180° (posterior to lateral directions) and the FullArc uses a full 360° arc setup arrangement. The prescription dose was set to 35.2 Gy. Results We identified a more conformal dose coverage for PTVs and a better sparing of OARs with used VMAT methods. For VMAT_AVD mean dose reductions in organs at risk can be realized, from 16 to 6.6 Gy, from 27.1 to 8.7 Gy and from 8.0 to 1.9 Gy for the heart, the thyroid and the gonads respectively, compared to the 3D-CRT treatment method. In addition we have found out a superiority of VMAT_AVD compared to the noAVD and FullArc trials with lower exposure to low-dose radiation to the lungs and breasts. Conclusions With the short partial-arc VMAT_AVD technique, dose exposures to radiosensitive OARS like the heart, the thyroid or the gonads can be reduced and therefore, maybe the occurrence of late sequelae is less likely. Furthermore the PTV conformity is increased. The advantages of the VMAT_AVD have to be weighed against the potentially risks induced by an increased low dose exposure compared to the 3D-CRT method.


Cancers ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 1082
Author(s):  
Vincent Bourbonne ◽  
Vincent Jaouen ◽  
Clément Hognon ◽  
Nicolas Boussion ◽  
François Lucia ◽  
...  

Purpose: Stereotactic radiotherapy (SRT) has become widely accepted as a treatment of choice for patients with a small number of brain metastases that are of an acceptable size, allowing for better target dose conformity, resulting in high local control rates and better sparing of organs at risk. An MRI-only workflow could reduce the risk of misalignment between magnetic resonance imaging (MRI) brain studies and computed tomography (CT) scanning for SRT planning, while shortening delays in planning. Given the absence of a calibrated electronic density in MRI, we aimed to assess the equivalence of synthetic CTs generated by a generative adversarial network (GAN) for planning in the brain SRT setting. Methods: All patients with available MRIs and treated with intra-cranial SRT for brain metastases from 2014 to 2018 in our institution were included. After co-registration between the diagnostic MRI and the planning CT, a synthetic CT was generated using a 2D-GAN (2D U-Net). Using the initial treatment plan (Pinnacle v9.10, Philips Healthcare), dosimetric comparison was performed using main dose-volume histogram (DVH) endpoints in respect to ICRU 91 guidelines (Dmax, Dmean, D2%, D50%, D98%) as well as local and global gamma analysis with 1%/1 mm, 2%/1 mm and 2%/2 mm criteria and a 10% threshold to the maximum dose. t-test analysis was used for comparison between the two cohorts (initial and synthetic dose maps). Results: 184 patients were included, with 290 treated brain metastases. The mean number of treated lesions per patient was 1 (range 1–6) and the median planning target volume (PTV) was 6.44 cc (range 0.12–45.41). Local and global gamma passing rates (2%/2 mm) were 99.1 CI95% (98.1–99.4) and 99.7 CI95% (99.6–99.7) respectively (CI: confidence interval). DVHs were comparable, with no significant statistical differences regarding ICRU 91′s endpoints. Conclusions: Our study is the first to compare GAN-generated CT scans from diagnostic brain MRIs with initial CT scans for the planning of brain stereotactic radiotherapy. We found high similarity between the planning CT and the synthetic CT for both the organs at risk and the target volumes. Prospective validation is under investigation at our institution.


2021 ◽  
Author(s):  
Hongbo Guo ◽  
Jiazhou Wang ◽  
Xiang Xia ◽  
Yang Zhong ◽  
Jiayuan Peng ◽  
...  

Abstract PurposeTo investigate the dosimetric impact of deep learning-based auto-segmentation of organs at risk (OARs) on nasopharyngeal and rectal cancer.Methods and MaterialsTwenty patients, including ten nasopharyngeal carcinoma (NPC) patients and ten rectal cancer patients, who received radiotherapy in our department were enrolled in this study. Two deep learning-based auto-segmentation systems, including an in-house developed system (FD) and a commercial product (UIH), were used to generate two auto-segmented OARs sets (OAR_FD and OAR_UIH). Treatment plans based on auto-segmented OARs and following our clinical requirements were generated for each patient on each OARs set (Plan_FD and Plan_UIH). Geometric metrics (Hausdorff distance (HD), mean distance to agreement (MDA), the Dice similarity coefficient (DICE) and the Jaccard index) were calculated for geometric evaluation. The dosimetric impact was evaluated by comparing Plan_FD and Plan_UIH to original clinically approved plans (Plan_Manual) with dose-volume indices and 3D gamma pass rates. Spearman’s correlation analysis was performed to investigate the correlation between dosimetric deviation and geometric metrics.ResultsFD and UIH could provide similar geometric performance in parotids, temporal lobes, lens, and eyes (DICE, p > 0.05). OAR_FD had better geometric performance in the optic nerves, oral cavity, larynx, and femoral heads (DICE, p < 0.05). OAR_UIH had better geometric performance in the bladder (DICE, p < 0.05). In dosimetric analysis, both Plan_FD and Plan_UIH had nonsignificant dosimetric differences compared to Plan_Manual for most PTV and OARs dose-volume indices. The only significant dosimetric difference was the Dmax of the left temporal lobe for Plan_FD vs. Plan_Manual (p = 0.05). Only one significant correlation was found between the mean dose of the femoral head and its HD index (R = 0.4, p = 0.01).ConclusionsDeep learning-based OARs auto-segmentation for NPC and rectal cancer has a nonsignificant impact on most PTV and OARs dose-volume indices. Correlations between the auto-segmentation geometric metric and dosimetric difference were not observed for most OARs.


Author(s):  
Loyce M. H. Chua ◽  
Eric P. P. Pang ◽  
Zubin Master ◽  
Rehena Sultana ◽  
Jeffrey K. L. Tuan ◽  
...  

Abstract Purpose: The aim of this study was to evaluate whether RapidPlan (RP) could generate clinically acceptable prostate volumetric modulated arc therapy (VMAT) plans. Methods: The in-house RP model was used to generate VMAT plans for 50 previously treated prostate cancer patients, with no additional optimisation being performed. The VMAT plans that were generated using the RP model were compared with the patients’ previous, manually optimised clinical plans (MP), none of which had been used for the development of the in-house RP prostate model. Differences between RP and MP in planning target volume (PTV) doses, organs at risk (OAR) sparing, monitor units (MU) and planning time required to produce treatment plans were analysed. Assessment of PTV doses was based on the conformation number (CN), homogeneity index (HI), D2%, D99% and the mean dose of the PTV. The OAR doses evaluated were the rectal V50 Gy, V65 Gy, V70 Gy and the mean dose, the bladder V65 Gy, V70 Gy and the mean dose, and the mean dose to both femurs. Results: D99% and mean dose of the PTV were lower for RP than for MP (p = 0·006 and p = 0·040, respectively).V50 Gy, V65 Gy and the mean dose to rectum were lower in RP than in MP (p < 0·001). V65 Gy, V70 Gy and the mean dose to bladder were lower in RP than in MP (p < 0·001). RP had enhanced the sparing of both femurs (p < 0·001) and significantly reduced the planning time to less than 5% of the time taken with MP. MU in RP was significantly higher than MP by an average of 52·5 MU (p < 0·001) and 46 out of the 50 RP plans were approved by the radiation oncologist. Conclusion: This study has demonstrated that VMAT plans generated using an in-house RP prostate model in a single optimisation for prostate patients were clinically acceptable with comparable or better plan quality compared to MP. RP can add value and improve treatment planning efficiency in a high-throughput radiotherapy department through reduced plan optimisation time while maintaining consistency in the plan quality.


2020 ◽  
Vol 93 (1110) ◽  
pp. 20190897
Author(s):  
Jennifer Cannon ◽  
Peter Bownes ◽  
Joshua Mason ◽  
Rachel Cooper

Objective: Assessment of the extent of variation in delineations and dose optimisation performed at multiple UK centres as a result of interobserver variation and protocol differences. Methods: CT/MR images of 2 cervical cancer patients previously treated with external beam radiotherapy (EBRT) and Brachytherapy were distributed to 11 UK centres. Centres delineated structures and produced treatment plans following their local protocol. Organ at risk delineations were assessed dosimetrically through application of the original treatment plan and target volume delineations were assessed in terms of variation in absolute volume and length, width and height. Treatment plan variation was assessed across all centres and across centres that followed EMBRACE II. Treatment plans were assessed using total EQD2 delivered and were compared to EMBRACE II dose aims. Variation in combined intracavitary/interstitial brachytherapy treatments was also assessed. Results: Brachytherapy target volume delineations contained variation due to differences in protocol used, window/level technique and differences in interpretations of grey zones. Planning target volume delineations were varied due to protocol differences and extended parametrial tissue inclusion. All centres met EMBRACE II plan aims for PTV V95 and high-riskclinical target volume D90 EQD2, despite variation in prescription dose, fractionation and treatment technique. Conclusion: Brachytherapy target volume delineations are varied due to differences in contouring guidelines and protocols used. Planning target volume delineations are varied due to the uncertainties surrounding the extent of parametrial involvement. Dosimetric optimisation is sufficient across all centres to satisfy EMBRACE II planning aims despite significant variation in protocols used. Advances in knowledge: Previous multi-institutional audits of cervical cancer radiotherapy practices have been performed in Europe and the USA. This study is the first of its kind to be performed in the UK.


2019 ◽  
Vol 19 (4) ◽  
pp. 327-332
Author(s):  
Ahmed Hadj Henni ◽  
Yann Lauzin ◽  
Nicolas Pirault ◽  
Brian Dubos ◽  
Maximilien Roge ◽  
...  

AbstractPurpose:The dosimetric impact of volumetric modulated arc therapy (VMAT) in lung cancer compared with 3D conformal radiotherapy (3DCRT) is well known. However, this improvement is often associated with an increase in low doses. The aim of this study is to quantify these results more accurately.Methods:For each patient treated with 3DCRT, a second VMAT treatment plan was calculated. Usual dosimetric parameters such as target coverage or dose to the organs at risk were used to achieve the comparisons.Results:For planning target volume, homogeneity and conformity indices showed superiority of VMAT (respectively 0·07 and 0·87) compared to 3DCRT (0·11 and 0·57). For spinal cord planning organ at risk volume, the median maximum dose was 45·6 Gy in 3DCRT against 19·3 Gy in VMAT. Heart volume receiving at least 35 Gy (V35) decreased from 15·64% in 3DCRT to 8·28% in VMAT. Oesophagus V50 was higher in 3DCRT (25·45%) than in VMAT (14·03%). The mean lung dose was 17·9 Gy in 3DCRT versus 15·5 Gy in VMAT. Moreover, volumes receiving 5, 10 and 15 Gy were not significantly different between the two techniques when VMAT was performed with partial arcs.Conclusion:All the dosimetric parameters were improved with VMAT compared to the 3DCRT without increasing low doses when using partial arcs.