scholarly journals Adverse Effects of Total Hip Arthroplasty on The Hip Abductor and Adductor Muscle Lengths and Moment Arms During Gait

2020 ◽  
Author(s):  
Xiangjun Hu ◽  
Nan Zheng ◽  
Wei-Chun Hsu ◽  
Jingwei Zhang ◽  
Huiwu Li ◽  
...  

Abstract Background: Precise evaluation the hip abductor and adductor muscles function in total hip arthroplasty (THA) patients during gait could help prevent postoperative complications and optimize the rehabilitation training program. The purpose of this study was to elucidate the effects of THA on the hip abductor and adductor muscle lengths and moment arms of in vivo patients during gait.Methods: Ten unilateral THA patients received CT scan and dual fluoroscopic imaging for the hip kinematics during gait. The hip abductor and adductor muscle insertions were digitized on the 3D hip model for the determination of their dynamic lines of action and moment arms. Changes in the hip abductor and adductor muscle lengths and moment arms of THA patients between the implanted and non-implanted sides were quantified during gait.Results: The adductor longus, adductor brevis, and pectineus of the implanted hips had significantly (P<0.05) less elongation than that of the non-implanted side during the stance phase. The gluteus medius, gluteus minimus, and piriformis moment arms of the implanted side were significantly shorter. The piriformis muscle moment arm was significantly larger. In the double support phase, the adductor magnus and adductor longus moment arms of the implanted sides were significantly decreased. Conclusions: Results suggested that the adverse effects of THA on hip stability. Development of a rehabilitation program considering the effects of THA is essential. Accurate surgical techniques may reduce the impact of THA on the peripheral muscles.

Author(s):  
Maximilian J. Hartel ◽  
Tareq Naji ◽  
Florian Fensky ◽  
Frank O. Henes ◽  
Darius M. Thiesen ◽  
...  

Abstract Purpose To investigate the range of indications of an anatomical-preshaped three-dimensional suprapectineal plate and to assess the impact of the bone mass density on radiologic outcomes in different types of acetabular fractures. Patients and methods A consecutive case series of 50 acetabular fractures (patient age 69 ± 23 years) treated with suprapectineal anatomic plates were analyzed in a retrospective study. The analysis included: Mechanism of injury, fracture pattern, surgical approach, need for additional total hip arthroplasty, intra- or postoperative complications, as well as bone mass density and radiological outcome on postoperative computed tomography. Results Most frequently, anterior column fracture patterns with and without hemitransverse components as well as associated two column fractures were encountered. The anterior intrapelvic approach (AIP) was used in 98% (49/50) of the cases as primary approach with additional utilization of the first window of the ilioinguinal approach in 13/50 cases (26%). Determination of bone density revealed impaired bone quality in 70% (31/44). Postoperative steps and gaps were significantly greater in this subgroup (p < 0.05). Fracture reduction quality for postoperative steps revealed anatomic results in 92% if the bone quality was normal and in 46% if impaired (p < 0.05). In seven cases (14%), the plate was utilized in combination with acute primary arthroplasty. Conclusion A preshaped suprapectineal plate provides good radiological outcomes in a variety of indications in a predominantly geriatric cohort. Impaired bone quality has a significantly higher risk of poor reduction results. In cases with extensive joint destruction, the combination with total hip arthroplasty was a valuable option.


Author(s):  
Anatole Vilhelm Wiik ◽  
Adeel Aqil ◽  
Bilal Al-Obaidi ◽  
Mads Brevadt ◽  
Justin Peter Cobb

Abstract Aim The length of the femoral stem in total hip arthroplasty (THA) is a practical consideration to prevent gait impairment. The aim of this study was to determine if reducing the femoral stem length in THA would lead to impaired gait biomechanics. Methods Patients uniformly with the same brand implant of differing lengths (100 mm vs 140–166 mm) were taken retrospectively from a prospective trial introducing a new short stem. Twelve patients without any other disorder to alter gait besides contralateral differing length stem THA were tested at differing gradients and speed on a validated instrumented treadmill measuring ground reaction forces. An anthropometrically similar group of healthy controls were analysed to compare. Results With the same posterior surgical approach, the offset and length of both hips were reconstructed within 5 mm of each other with an identical mean head size of 36 mm. The short stem was the last procedure for all the hips with gait analysis occurring at a mean of 31 and 79 months postoperatively for the short and long stem THA, respectively. Gait analysis between limbs of both stem lengths demonstrated no statistical difference during any walking condition. In the 90 gait assessments with three loading variables, the short stem was the favoured side 51% of the time compared 49% for the long stem. Conclusion By testing a range of practical walking activities, no lower limb loading differences can be observed by reducing the femoral stem length. A shorter stem demonstrates equivalence in preference during gait when compared to a reputable conventional stem in total hip arthroplasty.


2021 ◽  
Author(s):  
Ahmed Negm ◽  
Milad Yavarai ◽  
Gian Jhangri ◽  
Robert Haennel ◽  
Allyson Jones

Abstract BackgroundThe increase rate seen in Total Hip Arthroplasty (THA) for younger patients has implications for future rehabilitation demands for primary and revision THA surgery. This study aims to determine the impact of a 6-week post-operative rehabilitation program designed for THA patients ≤ 60 years on physical activity (PA) and function compared to age- and a sex-matched control group received usual postoperative care at 12-week post-THA. MethodsIn this quasi-experimental study, a cohort of THA candidates was recruited during their 6-week postoperative visit to their surgeons. The out-patient rehabilitation program consisted of 12 structured exercise classes (2 hrs/class) over 6 weeks. Physical activity was assessed using Sense Wear Pro ArmbandTM [SWA]. Participants completed the Hip Osteoarthritis Outcome Score (HOOS), and THA satisfaction questionnaire before and immediately after the intervention. ResultsThe intervention group took significantly more steps/day at the follow-up compared to baseline. The intervention group had a higher mean change in the number of weekly PA bouts than the control group. Within the intervention groups, all HOOS subscales were significantly higher at the follow-up compared to baseline. ConclusionThe augmented rehabilitation program may have immediate effects on pain relief and symptom reduction for patients (≤60 years) following THA.


Author(s):  
Francesco Castagnini ◽  
Barbara Bordini ◽  
Monica Cosentino ◽  
Cristina Ancarani ◽  
Federica Mariotti ◽  
...  

Abstract Introduction Recurrent dislocations are still the most frequent reason for revision in total hip arthroplasty (THA). The impact of bearing surfaces on dislocations is still controversial. We hypothesized that: (1) bearing surfaces influence the revisions due to dislocations; (2) ceramic-on-ceramic reduced the revisions for dislocations in adjusted models; (3) Delta-on-Delta bearings reduced the revisions for dislocations in comparison to surfaces with cross-linked polyethylene. Materials and methods The regional arthroplasty registry was enquired about bearing surfaces and revisions for dislocations and instability. Unadjusted and adjusted rates were provided, including sex, age (<65 years or ≥65 years), head diameter (≤28 mm or >28 mm; <36 mm or ≥36 mm) as variables. 44,065 THAs were included. Results The rate of revisions for dislocations was significantly lower in ceramic-on-ceramic and metal-on-metal bearings (unadjusted rates). After adjusting for age, sex, and head size (36 and 28 mm), hard-on-hard bearings were protective (p < 0.05): ceramic-on-ceramic had a lower risk of revisions due to dislocation than ceramic-on-polyethylene (HR 1.6, 95% CI 1.2–2.2 p = 0.0009). The rate of revisions for dislocation was similar in bearings with cross-linked polyethylene and Delta-on-Delta articulations, in unadjusted and adjusted models. Conclusion Bearings with conventional polyethylene were more predisposed to dislocations. Currently adopted bearings exerted no significant influence on revisions due to dislocations. These findings could be primarily related to wear, but due to the time distribution, soft tissue envelopes and surface tension may also play a role. Pre-clinical biomechanical evaluations and prospective matched cohort studies are required to draw definitive conclusions.


1995 ◽  
Vol &NA; (319) ◽  
pp. 77???84 ◽  
Author(s):  
Michael J. Chmell ◽  
David Rispler ◽  
Robert Poss

Sign in / Sign up

Export Citation Format

Share Document