scholarly journals The value of S-Detect for the differential diagnosis of breast masses on ultrasound: a systematic review and pooled meta-analysis

2020 ◽  
Vol 22 (2) ◽  
pp. 211
Author(s):  
Jun Li ◽  
Tian Sang ◽  
Wen-Hui Yu ◽  
Meng Jiang ◽  
Shu-Yan Hunag ◽  
...  

Aim: To evaluate the value of S-Detect (a computer aided diagnosis system using deep learning) in breast ultrasound (US) for discriminating benign and malignant breast masses.Material and methods: A literature search was performed and relevant studies using S-Detect for the differential diagnosis of breast masses were selected. The quality of included studies was assessed using a Quality Assessment of Diagnostic Accuracy Studies (QUADAS) questionnaire. Two review authors independently searched the articles and assessed the eligibility of the reports.Results: A total of ten studies were included in the meta-analysis. The pooled estimates of sensitivity and specificity were 0.82 (95%CI: 0.77-0.87) and 0.86 (95%CI: 0.76-0.92), respectively. In addition, the diagnostic odds ratios, positive likelihood ratio and negative likelihood ratio were 28 (95%CI: 16- 49), 5.7 (95%CI: 3.4-9.5), and 0.21 (95%CI: 0.16-0.27), respectively. Area under the curve was 0.89 (95%CI: 0.86-0.92). No significant publication bias was observed.Conclusions: S-Detect exhibited a favourable diagnostic value in assisting physicians discriminating benign and malignant breast masses and it can be considered as a useful complement for conventional US.

2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2020 ◽  
Author(s):  
Ke Wang ◽  
Shan Cong ◽  
Tiangang Ma ◽  
Xin Di ◽  
Chang Tian ◽  
...  

Abstract The aim of the study was to conduct a meta-analysis to evaluate the accuracy of neutrophil CD64, procalcitonin (PCT), and interleukin-6 (IL-6) for the diagnosis of sepsis. The sample articles were searched in various databases to collect published studies on the diagnosis of sepsis by neutrophil CD64, PCT, and IL-6. By using the Stata SE 15.0 software, forest plots and the area under the summary receiver operating characteristic curves were drawn. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC) were calculated. 54 articles were included in the study. The number of studies that evaluated the diagnostic value of neutrophil CD64, PCT, and interleukin-6 were 20, 39, and 15, respectively. The pooled sensitivity, specificity, and AUC of neutrophil CD64 for the diagnosis of sepsis were 0.88 [95% confidence interval (CI), 0.81–0.92], 0.88 (95% CI, 0.83–0.91), and 0.94 (95% CI, 0.91–0.96), respectively. The pooled sensitivity, specificity, and AUC of PCT for the diagnosis of sepsis were 0.82 (95% CI, 0.78–0.85), 0.78 (95% CI, 0.74–0.82), and 0.87 (95% CI, 0.83–0.89), respectively. Subgroup analysis showed that the AUC for PCT diagnosis of intensive care unit (ICU) sepsis was 0.86 (95% CI, 0.83–0.89) and the AUC for PCT diagnosis of non-ICU sepsis was 0.82 (95% CI, 0.78–0.85). The pooled sensitivity, specificity, and AUC of IL-6 for the diagnosis of sepsis were 0.72 (95% CI, 0.65–0.78), 0.70 (95% CI, 0.62–0.76), and 0.77 (95% CI, 0.73–0.80), respectively. Of the three biomarkers studied, neutrophil CD64 showed the highest diagnostic value for sepsis, followed by PCT, and IL-6. On the other hand, PCT showed a better diagnostic value for the diagnosis of sepsis in patients with severe conditions compared with that in patients with non-severe conditions.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Chao Sun ◽  
Bin Wu ◽  
Jiang Pan ◽  
Lulu Chen ◽  
Wenxian Zhi ◽  
...  

Aim. Increasing evidence indicates that hepatic subcapsular flow (HSF) can serve as a noninvasive ultrasonographic marker for the early diagnosis of biliary atresia (BA). However, results regarding its diagnostic accuracy are inconsistent and inconclusive. We conducted this meta-analysis with an aim to systematically evaluate the diagnostic value of HSF in predicting BA. Methods. A comprehensive literature search of four databases was conducted to identify the eligible studies. All analyses were performed using STATA 12.0. Results. Nine studies from eight articles containing 368 patients and 469 controls were included in our meta-analysis. Briefly, the values for pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were 0.95 (95% CI 0.88-0.98), 0.92 (95% CI 0.85-0.96), 11.6 (95% CI 6.3-21.5), 0.06 (95% CI 0.02-0.14), 201 (95% CI 59-689), and 0.98 (95% CI 0.96-0.99), respectively. Additionally, metaregression along with subgroup analysis based on various covariates revealed the potential sources of heterogeneity and the detailed diagnostic value in each subgroup. Conclusion. Our meta-analysis showed that HSF assay could provide high accuracy in predicting BA patients and non-BA individuals. However, further studies with better design and larger sample size are required to support the results of the present study.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2020 ◽  
Vol 7 ◽  
Author(s):  
Ying Luo ◽  
Ying Xue ◽  
Liyan Mao ◽  
Qun Lin ◽  
Guoxing Tang ◽  
...  

Background: Tuberculous peritonitis (TP) is a common form of abdominal tuberculosis (TB). Diagnosing TP remains challenging in clinical practice. The aim of the present meta-analysis was to evaluate the diagnostic accuracy of peripheral blood (PB) T-SPOT and peritoneal fluid (PF) T-SPOT for diagnosing TP.Methods: PubMed, EmBase, Cochrane, Scopus, Google scholar, China national knowledge internet, and Wan-Fang databases were searched for relevant articles from August 1, 2005 to July 5, 2020. Statistical analysis was performed using Stata, Revman, and Meta-Disc software. Diagnostic parameters including pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were determined. Summary receiver operating characteristic curve was used to determine the area under the curve (AUC).Results: Twelve studies were eligible and included in the meta-analysis. The analysis showed that the pooled sensitivity and specificity of PB T-SPOT in diagnosing TP were 0.91 (95% CI, 0.88–0.94) and 0.78 (95% CI, 0.73–0.81), respectively, while the pooled PLR, NLR, and DOR were 4.05 (95% CI, 2.73–6.01), 0.13 (95% CI, 0.07–0.23), and 37.8 (95% CI, 15.04–94.98), respectively. On the other hand, the summary estimates of sensitivity, specificity, PLR, NLR, and DOR of PF T-SPOT for TP diagnosis were 0.90 (95% CI, 0.85–0.94), 0.78 (95% CI, 0.72–0.83), 6.35 (95% CI, 2.67–15.07), 0.14 (95% CI, 0.09–0.21), and 58.22 (95% CI, 28.76–117.83), respectively. Furthermore, the AUC of PB T-SPOT and PF T-SPOT for TP diagnosis were 0.91 and 0.94, respectively.Conclusions: Our results indicate that both PB T-SPOT and PF T-SPOT can be served as sensitive approaches for the diagnosis of TP. However, the unsatisfactory specificities of these two methods limit their application as rule-in tests for TP diagnosis. Furthermore, the standardization of the operating procedure of PF T-SPOT is further needed.


2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screen of relevant studies was performed in the PubMed, Web of Science and Embase databases using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Then, the data were analysed and processed by Meta-Disc software. Results A total of 7 studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were 0.75 (95% confidence interval [CI]: 0.70 to 0.79), 0.69 (95% CI: 0.66 to 0.72), 3.01 (95% CI: 1.84 to 4.93), 0.32 (95% CI: 0.19 to 0.53) and 10.20 (95% CI: 3.63 to 28.64), respectively. Subgroup analyses showed that use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI (0.86, 0.84 vs. 0.67, 0.60, respectively). Conclusion Serum D-dimer had a better diagnostic value than plasma D-dimer for the diagnosis of PJI.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xingyang Zhu ◽  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Yijin Li ◽  
Jiahao Li ◽  
...  

Abstract Background Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. Methods We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. Results Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. Conclusion The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes.


PLoS ONE ◽  
2021 ◽  
Vol 16 (5) ◽  
pp. e0251676
Author(s):  
Yan liu ◽  
Houfa Geng ◽  
Xuekui Liu ◽  
Mingfeng Cao ◽  
Xinhuan Zhang

Background Aim of this meta-analysis was to evaluate the overall diagnostic value of circulating mini miRNAs for papillary thyroid carcinoma (PTC) and to find the possible molecular marker with higher diagnostic value for PTC. Methods We searched the Pubmed, Cochrane and Embase database until June 2020. We selected relevant literatures associated with the diagnosis of PTC with circulating miRNAs. The number of cases in experimental group and the control group, sensitivity and specificity could be extracted from the literatures. Results We got 9 literatures including 2114 cases of PTC. Comprehensive sensitivity was 0.79, comprehensive specificity was 0.82, positive likelihood ratio was 4.3, negative likelihood ratio was 0.26, diagnostic advantage ratio was 16. The summary receiver operating characteristic curve was drawn and the Area Under the Curve was 0.87. Conclusions Circulating microRNAs may be promising molecular markers for the diagnosis of papillary thyroid carcinoma. Combined detection of certain serum microRNAs can improve the diagnostic accuracy of papillary thyroid carcinoma. Especially MiR-222 and miR-146b may be prime candidates for the diagnosis of PTC in Asian population.


2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screening of relevant studies was performed in the databases PubMed, Web of Science, and Embase using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Data were subsequently analysed and processed using Meta-Disc. Results Seven studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.75 (95% confidence interval [CI]: 0.70–0.79), 0.69 (95% CI: 0.66–0.72), 3.01 (95% CI: 1.84–4.93), 0.32 (95% CI: 0.19–0.53), and 10.20 (95% CI: 3.63–28.64), respectively. Subgroup analyses showed that the use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI . Conclusion Serum D-dimer was shown to have a better diagnostic value than plasma D-dimer for the diagnosis of PJI. Further research is required for clarification.


2019 ◽  
Author(s):  
Yulan Gu ◽  
Chuandan Wan ◽  
Jiaming Qiu ◽  
Yanhong Cui ◽  
Tingwang Jiang

AbstractThe applications of liquid biopsy have attracted much attention in biomedical research in recent years. Circulating cell-free DNA (cfDNA) in the serum may serve as a unique tumor marker in various types of cancer. Circulating tumor DNA (ctDNA) is a type of serum cfDNA found in patients with cancer and contains abundant information regarding tumor characteristics, highlighting its potential diagnostic value in the clinical setting. However, the diagnostic value of cfDNA as a biomarker in cervical cancer remains unclear. Here, we performed a meta-analysis to evaluate the applications of ctDNA as a biomarker in cervical cancer. A systematic literature search was performed using PubMed, Embase, and WANFANG MED ONLINE databases up to March 18, 2019. All literature was analyzed using Meta Disc 1.4 and STATA 14.0 software. Diagnostic measures of accuracy of ctDNA in cervical cancer were pooled and investigated. Fifteen studies comprising 1109 patients with cervical cancer met our inclusion criteria and were subjected to analysis. The pooled sensitivity and specificity were 0.52 (95% confidence interval [CI], 0.33–0.71) and 0.97 (95% CI, 0.91–0.99), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 16.0 (95% CI, 5.5–46.4) and 0.50 (95% CI, 0.33–0.75), respectively. The diagnostic odds ratio was 32 (95% CI, 10–108), and the area under the summary receiver operating characteristic curve was 0.92 (95% CI, 0.90– 0.94). There was no significant publication bias observed. In the included studies, ctDNA showed clear diagnostic value for diagnosing and monitoring cervical cancer. Our meta-analysis suggested that detection of human papilloma virus ctDNA in patients with cervical cancer could be used as a noninvasive early dynamic biomarker of tumors, with high specificity and moderate sensitivity. Further large-scale prospective studies are required to validate the factors that may influence the accuracy of cervical cancer diagnosis and monitoring.