Estimation of Biodegradation and Liquid-Solid Partitioning Coefficients for Selected PAHs in Municipal Wastewater Treatment

2009 ◽  
Vol 44 (2) ◽  
pp. 166-173
Author(s):  
Wayne J. Parker ◽  
Hugh D. Monteith ◽  
Vince Pileggi

Abstract Batch testing was employed to estimate model parameters that are required for predicting the fate of polynuclear aromatic hydrocarbons (PAHs) in wastewater treatment. Linear partitioning was found to describe the partitioning of PAHs to solids and was best described when the soluble phase of the PAHs was determined by centrifugation alone. The liquid-solid partitioning coefficients obtained for primary and secondary sludges were statistically different, with the latter being higher than the former for most of the PAHs examined in this study. Temperature had a significant impact on the estimated biodegradation rate coefficients (Kb). The biodegradation rate coefficients for anthracene and phenanthrene (three-ring PAHs) were statistically different from benzo(a)anthracene and chrysene (four-ring PAHs). The presence of a nitro-adduct on acenaphthene resulted in a substantial increase in the Kb relative to the unsubstituted anthracene and phenanthrene. A sensitivity analysis revealed that the removal of PAHs in a full-scale wastewater treatment plant was most sensitive to the value of the liquid-solid partitioning coefficients. Approximately 60% of the PAHs were removed from the wastewater stream through partitioning to both primary and secondary solids, and subsequent discharge.

2009 ◽  
Vol 59 (7) ◽  
pp. 1291-1297
Author(s):  
H. Poutiainen ◽  
S. Laitinen ◽  
P. Juntunen ◽  
H. Heinonen-Tanski

We describe a novel application for a microwave on-line sensor to measure the total solids (TS) load entering a municipal wastewater treatment plant (WWTP) from slaughterhouse sewage and some sanitary wastewaters. Measuring this kind of wastewater stream is very challenging, because it contains a high, but varying organic load with nitrogen, phosphorus and microorganisms. The reliability of the measured signal was studied by comparison with laboratory analyses and a correlation is presented of TS-value with other parameters that are typically followed in a wastewater treatment process. The results suggest that on-line microwave sensoring could be used to monitor total solids in wastewater influent. Our results show that the on-line microwave sensor and laboratory reference analyses give similar results with a good correlation between the two techniques. Furthermore, we demonstrate that the total solids values correlate well with conductivity, total nitrogen and BOD7 values but not with phosphorus, pH and temperature.


1994 ◽  
Vol 30 (4) ◽  
pp. 125-132 ◽  
Author(s):  
D. Carnimeo ◽  
E. Contini ◽  
R. Di Marino ◽  
F. Donadio ◽  
L. Liberti ◽  
...  

The pilot investigation on the use of UV as an alternative disinfectant to NaOCI was started in 1992 at Trani (South Italy) municipal wastewater treatment plant (335 m3/h). The results collected after six months continuous operation enabled us to compare UV and NaOCl disinfection effectiveness on the basis of secondary effluent characteristics, quantify photoreactivation effects, evidence possible DBP formation and assess costs.


1997 ◽  
Vol 35 (6) ◽  
pp. 63-70 ◽  
Author(s):  
Yoshimasa Watanabe ◽  
Yoshihiko Iwasaki

This paper describes a pilot plant study on the performance of a hybrid small municipal wastewater treatment system consisting of a jet mixed separator(JMS) and upgraded RBC. The JMS was used as a pre-treatment of the RBC instead of the primary clarifier. The treatment capacity of the system was fixed at 100 m3/d, corresponding to the hydraulic loading to the RBC of 117 L/m2/d. The effluent from the grid chamber at a municipal wastewater treatment plant was fed into the hybrid system. The RBC was operated using the electric power produced by a solar electric generation panel with a surface area of 8 m2 under enough sunlight. In order to reduce the organic loading to the RBC, polyaluminium chloride(PAC) was added to the JMS influent to remove the colloidal and suspended organic particles. At the operational condition where the A1 dosage and hydraulic retention time of the JMS were fixed at 5 g/m3 and 45 min., respectively, the average effluent water quality of hybrid system was as follows: TOC=8 g/m3, Total BOD=8 g/m3, SS=8 g/m3, Turbidity=6 TU, NH4-N=7 g/m3, T-P=0.5 g/m3. In this operating condition, electric power consumption of the RBC for treating unit volume of wastewater is only 0.07 KWH/m3.


Water ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1339
Author(s):  
Javier Bayo ◽  
Sonia Olmos ◽  
Joaquín López-Castellanos

This study investigates the removal of microplastics from wastewater in an urban wastewater treatment plant located in Southeast Spain, including an oxidation ditch, rapid sand filtration, and ultraviolet disinfection. A total of 146.73 L of wastewater samples from influent and effluent were processed, following a density separation methodology, visual classification under a stereomicroscope, and FTIR analysis for polymer identification. Microplastics proved to be 72.41% of total microparticles collected, with a global removal rate of 64.26% after the tertiary treatment and within the average retention for European WWTPs. Three different shapes were identified: i.e., microfiber (79.65%), film (11.26%), and fragment (9.09%), without the identification of microbeads despite the proximity to a plastic compounding factory. Fibers were less efficiently removed (56.16%) than particulate microplastics (90.03%), suggesting that tertiary treatments clearly discriminate between forms, and reporting a daily emission of 1.6 × 107 microplastics to the environment. Year variability in microplastic burden was cushioned at the effluent, reporting a stable performance of the sewage plant. Eight different polymer families were identified, LDPE film being the most abundant form, with 10 different colors and sizes mainly between 1–2 mm. Future efforts should be dedicated to source control, plastic waste management, improvement of legislation, and specific microplastic-targeted treatment units, especially for microfiber removal.


Proceedings ◽  
2021 ◽  
Vol 52 (1) ◽  
pp. 3
Author(s):  
Luis F. Carmo-Calado ◽  
Roberta Mota-Panizio ◽  
Gonçalo Lourinho ◽  
Octávio Alves ◽  
I. Gato ◽  
...  

The technical-economic analysis was carried out for the production of sludge-derived fuel from a municipal wastewater treatment plant (WWTP). The baseline for the analysis consists of a sludge drying plant, processing 6 m3 of sludge per day and producing a total of about 1 m3 of combustible material with 8% of moisture and a higher calorific power of 18.702 MJ/kg. The transformation of biofuel into energy translates into an electricity production of about 108 kW per 100 kg of sludge. The project in the baseline scenario demonstrated feasibility with a payback time of about six years.


2000 ◽  
Vol 41 (7) ◽  
pp. 31-37 ◽  
Author(s):  
E. Carraro ◽  
E. Fea ◽  
S. Salva ◽  
G. Gilli

The aim of this study was to assess the impact of a municipal wastewater treatment plant (MWTP) on the occurrence of Cryptosporidium oocysts and Giardia cysts in the receiving water. All MWTP effluent samples were Giardia and Cryptosporidium contaminated, although low mean values were found for both parasites (0.21±0.06 oocysts/L; 1.39±0.51 cysts/L). Otherwise, in the raw sewage a greater concentration was detected (4.5±0.3 oocysts/L; 53.6±6.8 cysts/L). The major occurrence of Giardia over Cryptosporidium, both in the influent and in the effluent of the MWTP, is probably related to the human sewage contribution to the wastewater. Data on protozoa contamination of the receiving water body demonstrated similar concentrations in the samples collected before (0.21±0.07 oocysts/L; 1.31±0.38 cysts/L) and after (0.17±0.09 oocysts/L and 1.01±1.05 cysts/L) the plant effluent discharge. The results of this study suggest that the MWTP has no impact related to Giardia and Cryptosporidium river water contamination, and underline the need for investigation into the effectiveness of these protozoa removal by less technologically advanced MWTPs which are the most widespread and could probably show a lower ability to reduce protozoa.


Sign in / Sign up

Export Citation Format

Share Document