Enhancing Nitrogen Removal in Activated Sludge with Fixed Biomass

1990 ◽  
Vol 22 (1-2) ◽  
pp. 127-135 ◽  
Author(s):  
M. Bonhomme ◽  
F. Rogalla ◽  
G. Boisseau ◽  
J. Sibony

To upgrade existing activated sludge treatment plants, different techniques that would remove an important flux of nitrogen rapidly on a great number of units were investigated. Nitrification with conventional activated sludge systems requires considerable multiplication of tankage volume. The necessary investment and space is not always available, especially since many older plants are now in urbanized areas. To lower the nitrogen load in receiving water, the first priority should be to obtain partial nitrogen removal with existing plants, using methods that are simple to adapt.Three techniques were tested on large scale: submerged elements in aeration basin to add fixed biomass, contact stabilisation that allows a higher sludge age in the same tankage volume, and adding submerged biotower packings as a tertiary aeration stage. In a full scale unit (4000 m3/d), one complete section of the plant fitted with biofilter packing was operated in parallel with a similar unmodified section as reference. The volume occupied by the fixed beds was varied between 20 and 40 % of the tank. The submerged elements improved removal efficiency, to maintain effluent quality at higher loadings or obtain lower residual pollution values in existing plants. The biofilm evolution and the hydraulic behaviour of the packing was followed. No significant change in sludge settleability was observed, but fixed biomass addition reduced sludge production because of a lower overall mass loading. The resulting higher sludge age allowed the ammonia oxidizers to remain in the mixed population beyond usual F/M limits, but no installation of nitrifiers on the support media could be observed. To verify the limits of immersed plastic surfaces for nitrification, an aerated column was fed with effluent of a highly loaded activated sludge plant. In opposition to carriers submerged in mixed liquor, nitrifier attachment was obtained, and COD and SS removal for effluent polishing was achieved. With a carbon loading exceeding 1,5 kg COD/m3 d, a maximum oxidation rate of 0,4 kg N-NH4/m3 d could be obtained. A pilot unit was tested to assess the potential volume reduction for nitrogen elimination by contact stabilisation. This configuration stores the highly concentrated return sludge in a reaeration basin, and keeping only the minimum detention time in the contact basin to obtain nitrification. Also, an increased carbon load in the contact basin enhances denitrification. For urban wastewaters with a COD/N ratio of about 10, complete oxidation and partial removal of nitrogen were obtained with a volume loading of 1,5 kg COD/m3 d. Nitrogen removal rates of 0,15 kg N/m3 d were measured both in the anoxic and the aerobic part of the contact basin. The contact stabilisation mode was then tested on full scale combined with submerged biomass carriers. A consistant nitrogen elimination of 50 % was obtained with aeration detention times of about 4 hours.

1989 ◽  
Vol 21 (12) ◽  
pp. 1643-1646 ◽  
Author(s):  
F. Rogalla ◽  
G. Bacquet ◽  
M. Bonhomme ◽  
M. Boisseau

To upgrade existing activated sludge treatment plants, the effect of submerged elements in the aeration basins was verified. In a full scale unit, one complete section of the plant fitted with biofilter packing was operated in parallel with a similar unmodified section as reference. The volume occupied by the fixed beds was varied between 20 and 40 % of the tank. The biofilm evolution and hydraulic behaviour of the packing was followed. No significani change in sludge settleability was observed, but fixed biomass addition reduced sludge production. The submerged elements improve removal efficiency at higher loads. Effluent quality can be maintained even though loadings are increased. Existing treatment plants can thus be adapted to higher loads without additional basin volume. For a constant loading, the basins with biomass carriers improved residual pollution values. Higher purification standards can thus be met without increasing plant capacity.


1999 ◽  
Vol 39 (4) ◽  
pp. 55-60 ◽  
Author(s):  
J. Alex ◽  
R. Tschepetzki ◽  
U. Jumar ◽  
F. Obenaus ◽  
K.-H. Rosenwinkel

Activated sludge models are widely used for planning and optimisation of wastewater treatment plants and on line applications are under development to support the operation of complex treatment plants. A proper model is crucial for all of these applications. The task of parameter calibration is focused in several papers and applications. An essential precondition for this task is an appropriately defined model structure, which is often given much less attention. Different model structures for a large scale treatment plant with circulation flow are discussed in this paper. A more systematic method to derive a suitable model structure is applied to this case. Results of a numerical hydraulic model are used for this purpose. The importance of these efforts are proven by a high sensitivity of the simulation results with respect to the selection of the model structure and the hydraulic conditions. Finally it is shown, that model calibration was possible only by adjusting to the hydraulic behaviour and without any changes of biological parameters.


2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


2020 ◽  
Vol 81 (2) ◽  
pp. 333-344
Author(s):  
Jianfeng Wen ◽  
Mark W. LeChevallier ◽  
Wendong Tao

Abstract Simultaneous nitrification and denitrification under low dissolved oxygen conditions is an energy-saving modification of the activated sludge process to achieve efficient nitrogen removal. Geographically distinct full-scale treatment plants are excellent platforms to address the links of microbial community with operating parameters. Mixed liquor samples were collected from a sequencing batch reactor plant, oxidation ditch plant, and step-feed activated sludge plant. Next-Generation Sequencing of the samples showed that the microbial communities were similar at the phylum level among the plants, being dominated by Proteobacteria. Microbial composition of functional groups was similar between the react fill and react phases of the sequencing batch reactors, among four sequencing batch reactors, and among four oxidation ditches. Nitrospira was the only identified genus of autotropic nitrifying bacteria with a relative abundance of 2.2–2.5% in the oxidation ditches and 0.4–0.7% at the other plants. Heterotrophic nitrifying–aerobic denitrifying bacteria were dominated by Dechloromonas with a relative abundance of 0.4–1.0%. Microbial community composition and nitrogen removal mechanisms were related to overall level and local zonation of dissolved oxygen, mixed liquor suspended solids concentration, nitrogen and organic loadings, and solids retention time. Low dissolved oxygen and low organic and nitrogen loadings favored growth of Nitrospira.


1990 ◽  
Vol 22 (1-2) ◽  
pp. 239-250 ◽  
Author(s):  
B. Andersson

A test program for the use of fixed bed processes in systems for nitrogen removal at an advanced sewage treatment plant is described. Results from studies on nitrification in a full scale trickling filter plant with different filter depths and at different wastewater temperatures are presented. Results from full scale experiments with denitrification/nitrification in a retrofitted activated sludge plant are also presented. The effect of an aerated submerged fixed bed in the aeration basin on nitrification was investigated. Observations of the biofilm formed on the fixed bed were made in microscope.


2008 ◽  
Vol 58 (3) ◽  
pp. 639-645 ◽  
Author(s):  
David Thauré ◽  
Cyrille Lemoine ◽  
Olivier Daniel ◽  
Nader Moatamri ◽  
Julien Chabrol

Following a promising study at pilot scale a new aeration control law has been implemented at a full scale wastewater treatment plant displaying a conventional activated sludge process. The new control law is based on the direct measurements of ammonium and nitrate concentration in the biological tank by ion selective electrodes. This control law features a cascade of two Predictive Function Controls and calculates an optimal air flow rate to be provided to the biomass through fine bubble diffusers. The results obtained at the full scale plant confirmed the high performance of this control strategy allowing to substantially reduce the amount of diffused air while providing an easy means to manage the effluent quality to the plant operator.


1996 ◽  
Vol 34 (3-4) ◽  
pp. 395-404 ◽  
Author(s):  
H. Yasui ◽  
K. Nakamura ◽  
S. Sakuma ◽  
M. Iwasaki ◽  
Y. Sakai

The authors have presented a new concept of excess sludge elimination treatment with recirculation of sludge via ozonation in the activated sludge process. This paper is intended to clarify the potential application of the process to municipal and industrial wastewater treatments. In a full-scale operational experiment lasting 10 months under 550 kg/d of BOD loading, no excess sludge was needed to be withdrawn and no significant accumulation of inorganic solids occurred in the aeration tank. Most of the inorganic compounds in the sludge were released to the soluble phase. Material balance indicated that one-third of ozonated sludge was mineralized via the recirculation treatment, and thereby the requirement of sludge mass to be treated was 3.3 times as much as sludge to be eliminated. Effluent TOC was slightly higher than under the conventional activated sludge process, indicating that refractory TOC was released from the sludge eliminated by treatment. The amount of released TOC corresponded to less than 2 weight % of eliminated sludge under recirculation rates below 30% of total biomass in the aeration tank in a day, but increased at higher recirculation rates. The operation costs associated with the process were estimated to be lower than those of conventional dewatering and disposal.


Sign in / Sign up

Export Citation Format

Share Document