Competition in biofilms

1994 ◽  
Vol 29 (10-11) ◽  
pp. 263-270 ◽  
Author(s):  
T. C. Zhang ◽  
Y. C. Fu ◽  
P. L. Bishop

Competitions in biofilms for substrate and space have been studied by using a microelectrode technique and a microslicing technique. Three different kinds of biofilms, cultured by laboratory-scale rotating drum biofilm reactors (RDBR) with synthetic wastewater, have been used as test materials. Oxygen, ammonium-nitrogen, nitrate-nitrogen, and pH concentration profiles in the biofilms were measured using microelectrodes. Experimental results showed that: 1) an increase of organic loading rate would result in a decrease of DO concentration in the biofilm. However, after the organic loading rate exceeded a certain value, the oxygen profiles within the biofilm did not change any more; 2) Heterotrophs competed for oxygen with nitrifiers, which resulted in the inhibition of nitrification because of the shortage of oxygen. Glucose itself, however, did not inhibit the nitrification processes; and 3) The competition for substrate in biofilms resulted in a stratified biofilm structure. Experiments showed that competition in biofilms resulted in non-uniform spatial distributions of bacterial populations and metabolically active bacteria. The spatial distributions of biotic and abiotic components in turn affected the substrate transfer and substrate competition within the biofilm. Traditional biofilm modelling will fail in many cases if they are based on substrate removal kinetics and uniform distributions of biofilm properties.

2013 ◽  
Vol 2 (2) ◽  
pp. 131-135
Author(s):  
Z Yavari ◽  
H Izanloo ◽  
K Naddafi ◽  
H.R Tashauoei ◽  
M Khazaei

Renewable energy will have an important role as a resource of energy in the future. Microbial fuel cell (MFC) is a promising method to obtain electricity from organic matter andwastewater treatment simultaneously. In a pilot study, use of microbial fuel cell for wastewater treatment and electricity generation investigated. The bacteria of ruminant used as inoculums. Synthetic wastewater used at different organic loading rate. Hydraulic retention time was aneffective factor in removal of soluble COD and more than 49% removed. Optimized HRT to achieve the maximum removal efficiency and sustainable operation could be regarded 1.5 and 2.5 hours. Columbic efficiency (CE) affected by organic loading rate (OLR) and by increasing OLR, CE reduced from 71% to 8%. Maximum voltage was 700mV. Since the microbial fuel cell reactor considered as an anaerobic process, it may be an appropriate alternative for wastewater treatment


2015 ◽  
Vol 72 (8) ◽  
pp. 1274-1282 ◽  
Author(s):  
Mojtaba Torkaman ◽  
Seyed Mehdi Borghei ◽  
Sepehr Tahmasebian ◽  
Mohammad Reza Andalibi

A moving bed biofilm reactor with pre-denitrification configuration was fed with a synthetic wastewater containing high chemical oxygen demand (COD) and ammonia. By changing different variables including ammonium and COD loading, nitrification rate in the aerobic reactor and denitrification rate in the anoxic reactor were monitored. Changing the influent loading was achieved via adjusting the inlet COD (956–2,096 mg/L), inlet ammonium (183–438 mg/L), and hydraulic retention time of the aerobic reactor (8, 12, and 18 hours). The overall organic loading rate was in the range of 3.60–17.37 gCOD/m2·day, of which 18.5–91% was removed in the anoxic reactor depending on the operational conditions. Considering the complementary role of the aerobic reactor, the overall COD removal was in the range 87.3–98.8%. In addition, nitrification rate increased with influent ammonium loading, the maximum rate reaching 3.05 gNH4/m2·day. One of the most important factors affecting nitrification rate was influent C:N entering the aerobic reactor, by increasing which nitrification rate decreased asymptotically. Nitrate removal efficiency in the anoxic reactor was also controlled by the inlet nitrate level entering the anoxic reactor. Furthermore, by increasing the nitrate loading rate from 0.91 to 3.49 gNO/m3·day, denitrification rate increased from 0.496 to 2.47 gNO/m3·day.


2012 ◽  
Vol 66 (4) ◽  
pp. 850-857 ◽  
Author(s):  
K. Q. Bao ◽  
J. Q. Gao ◽  
Z. B. Wang ◽  
R. Q. Zhang ◽  
Z. Y. Zhang ◽  
...  

Synthetic wastewater was treated using a novel system integrating the reversed anoxic/anaerobic/oxic (RAAO) process, a micro-electrolysis (ME) bed and complex biological media. The system showed superior chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal rates. Performance of the system was optimised by considering the influences of three major controlling factors, namely, hydraulic retention time (HRT), organic loading rate (OLR) and mixed liquor recirculation (MLR). TP removal efficiencies were 69, 87, 87 and 83% under the HRTs of 4, 8, 12 and 16 h. In contrast, HRT had negligible effects on the COD and TN removal efficiencies. COD, TN and TP removal efficiencies from synthetic wastewater were 95, 63 and 87%, respectively, at an OLR of 1.9 g/(L·d). The concentrations of COD, TN and TP in the effluent were less than 50, 15 and 1 mg/L, respectively, at the controlled MLR range of 75–100%. In this system, organics, TN and TP were primarily removed from anoxic tank regardless of the operational conditions.


2006 ◽  
Vol 53 (9) ◽  
pp. 79-85 ◽  
Author(s):  
Z.H. Li ◽  
T. Kuba ◽  
T. Kusuda

In order to evaluate the characteristics of aerobic granular sludge, a sequencing batch reactor, feeding with synthetic wastewater at the organic loading rate of 8 kg COD/m3 d, was employed on the laboratory scale. Granules occurred in the reactor within 1 week after the inoculation from conventional flocculent sludge. Aerobic granular sludge was characterised by the outstanding settling properties and considerable contaminates removal efficiencies. The SVI30 values were in the range of 20 to 40 ml g−1. However, the sludge volume index of short settling time (e.g. SVI10 – 10 min) is suggested to describe the fast settling properties of aerobic granular sludge. The potential application in the decentralised system is evaluated from the point view of footprint and high bioactivity. The occurrence of sloughing, resulting from the outgrowth of filamentous organisms, would be responsible for the instability of aerobic granules. The starvation phase should therefore be carefully controlled for the maintenance and stability of aerobic granular sludge system.


1999 ◽  
Vol 40 (8) ◽  
pp. 229-236 ◽  
Author(s):  
F. Fdz-Polanco ◽  
M. D. Hidalgo ◽  
M. Fdz-Polanco ◽  
P. A. García Encina

In the last decade Polyethylene Terephthalate (PET) production is growing. The wastewater of the “Catalana de Polimers” factory in Barcelona (Spain) has two main streams of similar flow rate, esterification (COD=30,000 mg/l) and textile (COD=4000 mg/l). In order to assess the anaerobic treatment viability, discontinuous and continuous experiments were carried out. Discontinuous biodegradability tests indicated that anaerobic biodegradability was 90 and 75% for esterification and textile wastewater. The textile stream revealed some tendency to foam formation and inhibitory effects. Nutrients, micronutrients and alkali limitations and dosage were determined. A continuous lab-scale UASB reactor was able to treat a mixture of 50% (v) esterification/textile wastewater with stable behaviour at organic loading rate larger than 12 g COD/l.d (0.3 g COD/g VSS.d) with COD removal efficiency greater than 90%. The start-up period was very short and the recuperation after overloading accidents was quite fast, in spite of the wash-out of solids. From the laboratory information an industrial treatment plant was designed and built, during the start-up period COD removal efficiencies larger than 90% and organic loading rate of 0.6 kg COD/kg VSS.d (5 kg COD/m3.d) have been reached.


2000 ◽  
Vol 42 (12) ◽  
pp. 115-121 ◽  
Author(s):  
B. Wang ◽  
Y. Shen

A study on the performance of an Anaerobic Baffled Reactor(ABR) as a hydrolysis-acidogenesis unit in treating the mixed wastewater of landfill leachate and municipal sewage in different volumetric ratios was carried out. The results showed that ABR substantially improved the biological treatability of the mixed wastewater by increasing its BOD5/COD ratio to 0.4–0.6 from the initial values of 0.15–0.3. The formation of bar-shaped granular sludge of 0.5–5 mm both in diameter and length with an SVI of 7.5–14.2 ml/g was observed in all compartments of the ABR when the organic loading rate reached 4.71 kgCOD/m3 · d. The effects of the ratios of NH4+-N/COD and COD/TP in mixed wastewater on the operational performance were also studied, from which it was found that a reasonable NH4+-N/COD ratio should be lower than 0.02, and the phosphorus supplement was needed when the volumetric ratio was higher than 4:6 for stable operation of ABR.


2021 ◽  
Vol 123 ◽  
pp. 52-59
Author(s):  
L. Megido ◽  
L. Negral ◽  
Y. Fernández-Nava ◽  
B. Suárez-Peña ◽  
P. Ormaechea ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document