The effect of operational conditions on the sludge specific methanogenic activity and sludge biodegradability

2009 ◽  
Vol 59 (9) ◽  
pp. 1847-1853 ◽  
Author(s):  
R. C. Leitão ◽  
S. T. Santaellla ◽  
A. C. van Haandel ◽  
G. Zeeman ◽  
G. Lettinga

The effects of hydraulic retention time (HRT) and influent COD concentration (CODInf) on Specific Methanogenic Activity (SMA) and the biodegradability of an anaerobic sludge need to be elucidated because of the discordant results available in literature. This information is important for the operation of anaerobic reactors and design of the sludge post-treatment unit. For this study, sludge samples obtained from eight pilot-scale Upflow Anaerobic Sludge Blanket (UASB) reactors were tested. The reactors were fed with municipal wastewater and operated with different sets of HRT and influent concentrations until the steady state was established. The results show that at a lower HRT, sludge with relatively higher SMA develops. A slight trend of declining SMA at increasing CODInf was found for reactors operated at longer HRTs; however, further experiments are necessary for more definitive conclusions. The sludge from reactors operated at longer HRTs and with lower CODInf resulted in lower biodegradability. Results also showed that it is ineffective to design a UASB reactor with a longer HRT to cope with organic shock loads.

2005 ◽  
Vol 52 (1-2) ◽  
pp. 299-305 ◽  
Author(s):  
R.C. Leitão ◽  
J.A. Silva-Filho ◽  
W. Sanders ◽  
A.C. van Haandel ◽  
G. Zeeman ◽  
...  

In this investigation, the performance of Upflow Anaerobic Sludge Blanket (UASB) reactors treating municipal wastewater was evaluated on the basis of: (i) COD removal efficiency, (ii) effluent variability, and (iii) pH stability. The experiments were performed using 8 pilot-scale UASB reactors (120 L) from which some of them were operated with different influent COD (CODInf ranging from 92 to 816 mg/L) and some at different hydraulic retention time (HRT ranging from 1 to 6 h). The results show that decreasing the CODInf, or lowering the HRT, leads to decreased efficiencies and increased effluent variability. During this experiment, the reactors could treat efficiently sewage with concentration as low as 200 mg COD/L. They could also be operated satisfactorily at an HRT as low as 2 hours, without problems of operational stability. The maximum COD removal efficiency can be achieved at CODInf exceeding 300 mg/L and HRT of 6 h.


2011 ◽  
Vol 64 (10) ◽  
pp. 1959-1966 ◽  
Author(s):  
K. Syutsubo ◽  
W. Yoochatchaval ◽  
I. Tsushima ◽  
N. Araki ◽  
K. Kubota ◽  
...  

In this study, continuous operation of a pilot-scale upflow anaerobic sludge blanket (UASB) reactor for sewage treatment was conducted for 630 days to investigate the physical and microbial characteristics of the retained sludge. The UASB reactor with a working volume of 20.2 m3 was operated at ambient temperature (16–29 °C) and seeded with digested sludge. After 180 days of operation, when the sewage temperature had dropped to 20 °C or lower, the removal efficiency of both total suspended solids (TSS) and total biochemical oxygen demand (BOD) deteriorated due to washout of retained sludge. At low temperature, the cellulose concentration of the UASB sludge increased owing to the rate limitation of the hydrolytic reaction of suspended solids in the sewage. However, after an improvement in sludge retention (settleability and concentration) in the UASB reactor, the process performance stabilized and gave sufficient results (68% of TSS removal, 75% of total BOD removal) at an hydraulic retention time (HRT) of 9.7 h. The methanogenic activity of the retained sludge significantly increased after day 246 due to the accumulation of Methanosaeta and Methanobacterium following the improvement in sludge retention in the UASB reactor. Acid-forming bacteria from phylum Bacteroidetes were detected at high frequency; thus, these bacteria may have an important role in suspended solids degradation.


2011 ◽  
Vol 64 (3) ◽  
pp. 610-617 ◽  
Author(s):  
Tarek Elmitwalli ◽  
Ralf Otterpohl

The treatment of grey water in two upflow anaerobic sludge blanket (UASB) reactors, operated at different hydraulic retention times (HRTs) and temperatures, was investigated. The first reactor (UASB-A) was operated at ambient temperature (14–25 °C) and HRT of 20, 12 and 8 h, while the second reactor (UASB-30) was operated at controlled temperature of 30 °C and HRT of 16, 10 and 6 h. The two reactors were fed with grey water from ‘Flintenbreite’ settlement in Luebeck, Germany. When the grey water was treated in the UASB reactor at 30 °C, total chemical oxygen demand (CODt) removal of 52–64% was achieved at HRT between 6 and 16 h, while at lower temperature lower removal (31–41%) was obtained at HRT between 8 and 20 h. Total nitrogen and phosphorous removal in the UASB reactors were limited (22–36 and 10–24%, respectively) at all operational conditions. The results showed that at increasing temperature or decreasing HRT of the reactors, maximum specific methanogenic activity of the sludge in the reactors improved. As the UASB reactor showed a significantly higher COD removal (31–64%) than the septic tank (11–14%) even at low temperature, it is recommended to use UASB reactor instead of septic tank (the most common system) for grey water pre-treatment. Based on the achieved results and due to high peak flow factor, a HRT between 8 and 12 h can be considered the suitable HRT for the UASB reactor treating grey water at temperature 20–30 °C, while a HRT of 12–24 h can be applied at temperature lower than 20 °C.


1997 ◽  
Vol 35 (8) ◽  
pp. 247-253 ◽  
Author(s):  
Herbert H. P. Fang ◽  
Ivan W. C. Lau ◽  
Denis W. C. Chung

The effects of nine common aromatic pollutants from chemical industry on the bioactivity of anaerobic granules were examined. The granules were obtained from an upflow anaerobic sludge blanket (UASB) reactor treating wastewater containing colloidal starch. The specific methanogenic activities (SMA) of granules were measured at 37°C in serum vials using 3000 mg/l of colloidal starch as substrate, plus individual pollutants at various concentrations. The toxicity was expressed by the IR50 and IC50 values, i.e. the toxicant/biomass ratio and concentration at which levels the granules exhibited only 50% of their original bioactivities. Results showed that in general the granules exhibited mild resistance to toxicity of aromatic pollutants, probably due to the granules' layered microstructure. The toxicities, which were dependent on the nature of chemical functional group, of the aromatic pollutants were in the following descending order: cresols > phenol > hydroxyphenols/phthalate > benzoate. There was only marginal difference between the toxicity of the steric isomers. For the seven phenolic pollutants, the more hydrophobic the functional group the higher the toxicity. The granules' resistance to toxicity suggested the plausibility of anaerobic treatment of wastewater from the chemical industry.


2013 ◽  
Vol 634-638 ◽  
pp. 182-186
Author(s):  
Juan Wang ◽  
Qin Zhong

With the aim to use anaerobic granular sludge, the methanogenic activity inhibition and recovery of anaerobic granular sludge from an industrial anaerobic reactor (s1) were investigated by measuring the methane volume at low pH. A lab-scale upflow anaerobic sludge blanket (UASB) reactor was inoculated with s1.s1 was used to remove Zn2+ in wastewater. The results show that activity of s1 is similar when the pH value is 6.5 to 7.0. The methane volume is obviously decreased when the pH value is 6.0. The activity is completely inhibited when the pH value is 4.5. The activity is fully recovered when the pH is above 6.5 and hardly recovers when the pH fell to 4.5. The main Zn2+ removal mechanism is chemical adsorption.


2021 ◽  
Vol 83 (8) ◽  
pp. 1920-1931
Author(s):  
M. J. Moya-Llamas ◽  
A. Trapote ◽  
D. Prats

Abstract An Upflow Anaerobic Sludge Blanket reactor combined with a two-stage membrane bioreactor were operated for 193 days in order to evaluate the biological removal of carbamazepine (CBZ) from low-strength municipal wastewater. The system worked in three different organic load stages (0.7 ± 0.1 kg COD·m−3·d−1, 0.4 ± 0.1 kg COD·m−3·d−1 and 0.1 ± 0.0 kg COD·m−3·d−1) to assess the impact of the influent OLR on operational parameters such as anaerobic and aerobic sludge retention time (SRT), acidity, volatile fatty acids (VFAs), biomass activity or biogas production. The highest carbamazepine removals were achieved during the anaerobic stage (UASB reactor), reaching averages of 48.9%, 48.0% and 38.2% operating at high, medium and low OLR, respectively. The aerobic treatment (MBR) served as post-treatment, improving the removals, and the global UASB-MBR system reached averages of 70.0%, 59.6% and 49.8% when the influent was at medium and low OLR, respectively. The results demonstrate the potential of combined biological systems on the removal of recalcitrant pharmaceuticals.


2002 ◽  
Vol 45 (10) ◽  
pp. 243-248 ◽  
Author(s):  
L. Seghezzo ◽  
R.G. Guerra ◽  
S.M. González ◽  
A.P. Trupiano ◽  
M.E. Figueroa ◽  
...  

The performance of a sewage treatment system consisting of a settler followed by an Upflow Anaerobic Sludge Bed (UASB) reactor is described. Mean ambient and sewage temperature were 16.5 and 21.6°C, respectively. Total Chemical Oxygen Demand (CODt) concentration averaged 224.2 and 152.6 mg/L, for raw and settled sewage, respectively. The effluent concentration was 68.5 mgCODt/L. Total and suspended COD removal efficiencies of approximately 70 and 80%, respectively, have been observed in the system at a mean Hydraulic Retention Time (HRT) of 2 + 5 h. Maximum COD removal efficiency was achieved in the UASB reactor when upflow velocity (Vup) was 0.43 m/h (HRT = 6 h). Mean Specific Methanogenic Activity (SMA) and Volatile Suspended Solids (VSS) concentration in the granular sludge bed were 0.11 gCOD-CH4/gVSS.d and 30.0 gVSS/Lsludge, respectively. SMA was inversely related to VSS concentration, and both parameters varied along the sludge bed height. The Solids Retention Time (SRT) in the reactor was 450 days. Sludge characteristics have not been affected by changes of up to one month in Vup in the range 0.28–0.85 m/h (HRT 3–9 h). This system or two UASB reactors in series could be an alternative for sewage treatment under moderate temperature conditions.


2021 ◽  
Vol 47 (1) ◽  
pp. 174-180
Author(s):  
Henrique Sousa do Nascimento ◽  
Geísa Vieira Vasconcelos Magalhães ◽  
José Demontier Vieira de Souza-Filho ◽  
Ronaldo Stefanutti ◽  
Ari Clecius Alves de Lima ◽  
...  

This study evaluated the use of two anaerobic bioreactors in the production of biogas from malt bagasse waste. Bioreactor B1 was loaded with a mixture of 600mL of anaerobic sludge, 300g of organic waste, taken from an upflow anaerobic sludge blanket (UASB) reactor, and 300g of malt bagasse residue. Bioreactor B2 was loaded with a mixture of 600g of organic waste and 600mL of anaerobic sludge taken from an UASB reactor. The anaerobic digestion processes lasted for 10 weeks and the produced methane fraction was measured in 5 occasions. Bioreactor B1 presented low methane production (7.2%) but Bioreactor B2 showed a much more signif- icant percentage, reaching up to 48.3%. The experiments were capable of reproducing largescale operational conditions, enabling increased results in biogas capturing and processing, strengthening sustainability and energy efficiency. The experiment also showed the importance of studying different types of organic waste, seeking optimization of anaerobic digestion pro- cesses.


2013 ◽  
Vol 699 ◽  
pp. 234-237
Author(s):  
Hong Fen Wang

A pilot-scale upflow anaerobic sludge blanket (UASB) reactor was used to study the sweet potato starch wastewater treatment performance and its influencing factors. Under normal temperature conditions, the operating parameters of sweet potato starch wastewater from UASB treatment was optimized, and the better conditions from different influent CODcr concentrations was obtained. The impacts from trace elements MgCl2, FeCl2, CoCl2, NiCl2 on physiological and biochemical characteristics of anaerobic granular sludge was developed.


Sign in / Sign up

Export Citation Format

Share Document