scholarly journals Results of a Pilot-Scale Disinfection Test using Peracetic Acid (PAA) at the Oak Ridge National Laboratory (ORNL) Sewage Treatment Plant (STP)

2017 ◽  
Author(s):  
Paul Allen Taylor
1998 ◽  
Vol 38 (7) ◽  
pp. 207-215 ◽  
Author(s):  
H. Takigami ◽  
N. Taniguchi ◽  
Y. Shimizu ◽  
S. Matsui

The toxicity of organic polymer flocculants used for the dewatering of municipal sludge was evaluated by using two different toxicity assays: the Closterium ehrenbergii algal toxicity test and the Bacillus subtilis rec-assay. The algal toxicity of the effluents from a pilot-scale sewage treatment plant was investigated with and without the addition of a flocculant (0, 0.05, 0.10 and 0.20 mg/L). No clear evidence on the toxicity caused by the flocculant was observed on both asexual and sexual reproduction tests of C. ehrenbergii. It was also found that the algal growth inhibition of various types of flocculants (i.e., cationic, anionic, amphoionic and non-ionic) was in the order of 1 to 20 mg/L, which was mainly due to a molecular weight (MW) fraction of greater than 100,000. The results of the B. subtilis rec-assay for these flocculants indicated that eight out of ten cationic flocculants caused the direct DNA damage with LC50 =0.1 to 10 mg/L. One of the genotoxic flocculants was also fractionated into their components by MW. The experimental results showed that the lethal effects were mainly contributed by the polymer fraction of MW greater than 100,000, although the genotoxicity was not detected in that fraction. Therefore, the detected genotoxicity of the flocculants could be caused by the combined effects of various components, such as polymers, oligomers, monomers and additives.


2014 ◽  
Vol 997 ◽  
pp. 770-776
Author(s):  
Feng Long Xie ◽  
Jian Jun Shen ◽  
Jiang Liu

Based on the pilot test, the feasibility of E lectrosorption Technology of industrial sewage treatment plant was studied. The result s show that, when the equipment w ater flow and electrode voltage appropriate, in the sewage plant industrial average conductivity row is 3277μS/cm, 4072μS/cm, averaged desalination rate is 74.8%, averaged water production rate is about 75.5%, average consu mption water of a ton is 2.46kW•H. E lectrosorption technology is g ood removal effect of salinity, chloride and total hardness , and water production rate is high, simple operation, can be used for desalination of industrial recyclin wastewater .


2021 ◽  
Vol 333 ◽  
pp. 12002
Author(s):  
Regina Damalerio ◽  
Aileen Orbecido ◽  
Michael Angelo Promentilla ◽  
Ramon Christian Eusebio ◽  
Liza Patacsil ◽  
...  

Water utilities, commercial and industrial establishments are required to upgrade or install new treatment systems to comply with the revised effluent standards issued by the Department of Environment and Natural Resources – Environment Management Bureau (DENR – EMB) which now includes removal and monitoring of nutrients (nitrogen and phosphorus components). One solution is to utilize a biological nutrient removal technology (BNRT) system capable of removing nutrients from sewage. The on-going study aims to investigate the performance of the pilot-scale system in the removal of nutrients from sewage. The designed pilot-scale anaerobic-anoxic-oxic (A2O) process with a total hydraulic retention time of 8.37 hrs. was operated in an existing sewage treatment plant (STP). System modification was adapted to ensure continuous operation. Dissolved oxygen (DO) and temperature of each compartment were evaluated after 45 days of system modification. The DO of the anaerobic and oxic compartment remained within the required range, while the internal recycling flowrate and/or aeration must be adjusted to achieve a DO concentration of 0.20 – 0.50 mg/L in the anoxic compartment. The research is financially supported by the Philippine Council for Industry, Energy and Emerging Technology Research and Development of the Department of Science and Technology (PCIEERD Project No. 04176).