scholarly journals Pilot-scale study on advanced treatment of tail water of urban sewage treatment plant by constructed wetlands with different plants

2019 ◽  
Vol 31 (2) ◽  
pp. 365-374 ◽  
Author(s):  
CEN Luyao ◽  
◽  
CHEN Ying ◽  
ZHANG Jin ◽  
LIU Min ◽  
...  
2014 ◽  
Vol 641-642 ◽  
pp. 384-389
Author(s):  
Rui Wu ◽  
Li Gang Xu ◽  
Dan Chen

As a cost-effective technology, using biological treatment technology to treat tail water has been gradually promoted in and abroad. Biological treatment technology uses the organic combination of water ecosystem to remove the organic pollutants and pollutants such as N and P which cause water eutrophication. This paper takes Jiangyin City Xinqiao Town Sewage Treatment Plant as example to construct bio-ecological combined constructed wetlands system near natural river course to treat tail water from sewage treatment plant and investigates the removal efficiency of combination process for COD, ammonia, TN and TP in tail water. The research indicates that bio-ecological combined constructed wetlands system has good removal efficiency for pollutants in tail water. And the average removal rate of COD, ammonia, TN and TP are 29%, 31%, 18%, and 8%; the average effluent concentration of them are 35.54mg/L, 0.97mg/L, 10.77 mg/L, and 0.11 mg/L. The result exactly matches the first grade A standard of Urban Sewage Treatment Plant Pollutant Discharge Standard (GB18918-2002). It has great potential for tail water treatment and is suitable for rural regions. The research result provides both the data and theoretical basis for improvement of biological treatment technology of tail water from sewage treatment plant, and also provides direct theoretical basis and practical experience for promotion and research of wetlands ecosystem.


2015 ◽  
Vol 10 (4) ◽  
pp. 688-694
Author(s):  
Yanjiao Gao ◽  
Runzhu Huang

In order to solve the problems of poor biodegradability and high concentrations of non-biodegradable substances from pharmaceutical wastewater after preliminary treatment, the organic components of the tail water (effluent from the preliminary treatment devises of the pharmaceutical industry wastewater treatment station) were analyzed and the method of ozonation-hydrolysis acidification was used to treat tail water from the pharmaceutical factory. The ozone dosage, the reaction time and the changes of biodegradability were studied. The results measured by GC-MS showed that there were 51 types of organic substances in tail water which reduce the biodegradability. The results of the tests showed that 30 mg/L of ozone and 60-minutes of oxidation time were suitable conditions. In the ozonation–hydrolysis acidification process the COD removal rate ranged from 20% to 50%. The test results showed that the ozonation-hydrolysis acidification method could effectively improve the biodegradability of wastewater and provide the foundation for the follow treatment in urban sewage treatment plant using biological methods.


2012 ◽  
Vol 610-613 ◽  
pp. 2085-2089
Author(s):  
Jia Feng Xie ◽  
Yun Long Yang ◽  
Jian Li

Applying surface flow constructed wetlands/subsurface flow constructed wetlands/UV disinfection compound constructed wetland treating sewage treatment plant tail water,introducing the technological process,engineering design parameters and equipment configuration,and summarizing the design characteristics. The operation results showed that the average removal rate of COD,NH3-N,TN and TP was 24.3%,36.8%,20.7% and 24.2% respectively,and The effluent can fully meet Standard A of the first class in GB18918-2002,“Standard for Discharge of Pollutants from Sewage Treatment Works in Towns and Cities”.


2020 ◽  
Vol 104 (2) ◽  
pp. 273-281 ◽  
Author(s):  
Guozhen Zhang ◽  
Kai Ma ◽  
Zixian Zhang ◽  
Xingbao Shang ◽  
Fuping Wu

Ecotoxicology ◽  
2016 ◽  
Vol 25 (10) ◽  
pp. 1849-1857 ◽  
Author(s):  
Dalel Belhaj ◽  
Khaled Athmouni ◽  
Bouthaina Jerbi ◽  
Monem Kallel ◽  
Habib Ayadi ◽  
...  

1998 ◽  
Vol 38 (7) ◽  
pp. 207-215 ◽  
Author(s):  
H. Takigami ◽  
N. Taniguchi ◽  
Y. Shimizu ◽  
S. Matsui

The toxicity of organic polymer flocculants used for the dewatering of municipal sludge was evaluated by using two different toxicity assays: the Closterium ehrenbergii algal toxicity test and the Bacillus subtilis rec-assay. The algal toxicity of the effluents from a pilot-scale sewage treatment plant was investigated with and without the addition of a flocculant (0, 0.05, 0.10 and 0.20 mg/L). No clear evidence on the toxicity caused by the flocculant was observed on both asexual and sexual reproduction tests of C. ehrenbergii. It was also found that the algal growth inhibition of various types of flocculants (i.e., cationic, anionic, amphoionic and non-ionic) was in the order of 1 to 20 mg/L, which was mainly due to a molecular weight (MW) fraction of greater than 100,000. The results of the B. subtilis rec-assay for these flocculants indicated that eight out of ten cationic flocculants caused the direct DNA damage with LC50 =0.1 to 10 mg/L. One of the genotoxic flocculants was also fractionated into their components by MW. The experimental results showed that the lethal effects were mainly contributed by the polymer fraction of MW greater than 100,000, although the genotoxicity was not detected in that fraction. Therefore, the detected genotoxicity of the flocculants could be caused by the combined effects of various components, such as polymers, oligomers, monomers and additives.


2013 ◽  
Vol 385-386 ◽  
pp. 857-861
Author(s):  
Xiao Ping Huang ◽  
Qi Xing Qing

On the basis of the computerized technological process control of sewage treatment in a urban sewage treatment plant in the Zone of Nanning, the author had brought forward a plan of PROFIBUS that based on automatic control system for sewage treatment, and designed the automatic control system diagram and the PROFIBUS network diagram for sewage treatment plant. At the same time, the author also made a study of techniques to control the sewage aeration, which was the most difficult problem in sewage treatment process. The fuzzy controller could indicate the changes of the water quality in treated sewage, effectively controlled the volume of aeration and then cut down the operation costs,it had produced good economic and social benefits.


Sign in / Sign up

Export Citation Format

Share Document