scholarly journals Evaluation of Next Generation Nuclear Power Plant (NGNP) Intermediate Heat Exchanger (IHX) Operating Conditions

2006 ◽  
Author(s):  
E. A. Harvego
2019 ◽  
Vol 34 (3) ◽  
pp. 238-242
Author(s):  
Rex Abrefah ◽  
Prince Atsu ◽  
Robert Sogbadji

In pursuance of sufficient, stable and clean energy to solve the ever-looming power crisis in Ghana, the Nuclear Power Institute of the Ghana Atomic Energy Commission has on the agenda to advise the government on the nuclear power to include in the country's energy mix. After consideration of several proposed nuclear reactor technologies, the Nuclear Power Institute considered a high pressure reactor or vodo-vodyanoi energetichesky reactor as the nuclear power technologies for Ghana's first nuclear power plant. As part of technology assessments, neutronic safety parameters of both reactors are investigated. The MCNP neutronic code was employed as a computational tool to analyze the reactivity temperature coefficients, moderator void coefficient, criticality and neutron behavior at various operating conditions. The high pressure reactor which is still under construction and theoretical safety analysis, showed good inherent safety features which are comparable to the already existing European pressurized reactor technology.


Author(s):  
Dong Zheng ◽  
Allen T. Vieira ◽  
Julie M. Jarvis ◽  
George P. Emsurak

The Ultimate Heat Sink (UHS) of a nuclear power plant is a complex cooling water system which serves the plant during normal and accident conditions. For some next generation nuclear plants, the UHS sizing is a major design and licensing analysis task. The analysis involves detailed modeling of the transient heat loads and the selection of worst-case meteorological data for the plant site. The UHS sizing requirements for a representative next generation nuclear power plant are evaluated on a month-to-month basis. This paper assesses the UHS water requirement for each month of year. The UHS analysis for a representative next generation nuclear plant with mechanical draft cooling towers and a water basin is used to determine the maximum evaporation of the basin for the worst-case meteorological data on a month-to-month basis. To size the cooling tower basin, automated methods have been developed which determine the highest evaporative losses from the basin and highest basin temperature over a 30-day design basis accident period. This paper also evaluates the month-to-month basin temperature changes. This assessment is done for a representative next generation nuclear power plant and considers the monthly historical meteorological data over 45 years. The result of this assessment of monthly UHS water requirement is of interest in assessing the margin in the UHS design. This monthly assessment is also useful in demonstrating that the automated methods used to establish the limiting 30-day meteorological condition are indeed accurate. In addition, these results may be useful in helping to plan plant maintenance activities.


Author(s):  
Guohui Cong ◽  
Ling Zhang

Environmental protection requirement is more and more critical now, and it increases the request to prevent dangerous liquid to leak outside in nuclear power plant too. Centrifugal pumps are the most important active equipments in nuclear power plant, but there is a shaft clearance between rotor and stator of centrifugal pump. The shaft clearance can lead pumped fluid to the outside, so the environment may be polluted by the leakage. In some critical conditions such as transferring high radioactive fluid in the pump, the leakage shall be totally forbidden. So solutions have to be found to make centrifugal pumps totally leak-free for applications in nuclear power plant. Normally there are three leak-free technologies for centrifugal pumps: mechanical seal with auxiliary system, canned motor and magnetic drive. In this paper, all the three leak-free technologies and some of their applications in EPR 3rd generation PWR nuclear power plants are presented and discussed. The results show that in EPR nuclear power plant, canned motor pumps can be preferably used for strict environmental requirement of leak-free if the pump power and operating conditions are applicable. For other conditions, pumps with double mechanical seal can also be used with additional sealing water system support. For centrifugal pumps with magnetic drive are not so applicable in high pressure condition, and the safety aspect is weaker than canned motor pumps, generally they are not used in EPR nuclear power plant at present.


Author(s):  
Yasuyoshi Taruta ◽  
Satoshi Yanagihara ◽  
Takashi Hashimoto ◽  
Shigeto Kobayashi ◽  
Yukihiro Iguchi ◽  
...  

Abstract Decommissioning of Nuclear Power Plant is a long-term project during which generations are expected to change. Therefore, it is necessary to appropriately transfer knowledge, technology and skills to the next generation. In recent years, in the world of decommissioning, attempts have been made to apply advanced technologies such as utilization of knowledge management and digital technology. This study describes adaptation in decommissioning from viewpoint of utilizing IT technology called digital twin and aspect of knowledge management.


Author(s):  
Li Li ◽  
Zhang Shengtao ◽  
Xu Zhao ◽  
Du Yu

For PWR, remote shutdown station (RSS) is a redundant control mean to shut down the reactor when main control room (MCR) inhabitation is challenged (e.g. fire, smoke...). Nowadays, due to nuclear power plants control measures were improved with DCS system, a full function DCS RSS was equipped and more essential equipment could be controlled on RSS. Under operating conditions that prohibit nuclear power plant operators to stay in the main control room, the operators should move to RSS and shutdown the reactor to ensure plant safety following <Moving to remote shutdown station when main control room is un-inhabitable operating strategy> (RSS strategy for short) to fallback the plant from power operation to cold shutdown. The original operating strategy by nature circulation is no longer the best choice both for operation safety and economy efficiency, and an optimized new strategy should be raised. Based on the former reason, an optimized operation strategy was raised in this paper. In the optimized strategy, all plant normal standard operation modes were considered as initial conditions, rather than only considering power operation condition in the original one. The fallback mode and fallback strategy for each initial condition was also designed and optimized. To accelerate the depression and heat removal process, a forced circulation operation strategy is adopted when the reactor coolant pumps are available, and less local operation was included by taking advantages of the full function operating measures on RSS. To simplify the whole procedure structure, the operation modules of other general operating procedures are reused. To validate the effectiveness of the optimized operating strategy, a full scope PWR simulation tool was employed to make thermo hydraulic calculation validation of the reactor response and also the remote control station HMI supporting validation. By simulating the original strategy and the optimized one and related analysis, we found that the optimized strategy is effective, and able to be executed based on the remote control station hardware. By executing the optimized strategy, the unit can fall back to the cold shutdown condition safely and a few hours were saved compared with the original strategy. The optimized strategy had already been implemented on real PWR nuclear power plant.


Sign in / Sign up

Export Citation Format

Share Document