scholarly journals Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up

2015 ◽  
Vol 9 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Mengmeng Wang ◽  
Christine Carole C Corpuz ◽  
Megumi Fujiwara ◽  
Minoru Tomita

Purpose : To compare the visual and optical outcomes of four multifocal intraocular lenses (IOLs) with three different near additions of +3.00 diopters (D), +3.75 D and +4.00 D. Methods : In this prospective study, 133 eyes of 88 patients were implanted with one of the following IOLs: AcrySof® ReSTOR® SN6AD1 (+3.00 D) for Group A, AcrivaUD Reviol BB MF 613 or BB MFM 611 (+3.75 D) for Group B, and AcrySof® ReSTOR® SN6AD3 (+4.00 D) for Group C. The visual acuity, refraction, intraocular pressure, tomography and corneal endothelial cell density (ECD) were compared between the three groups preoperatively and at 6 month postoperatively. Defocus curve, contrast sensitivity and higher order aberrations (HOAs) at 6 month postoperative visit were measured and compared. Results : There were no statistically significant differences in distance visual acuity, refraction, intraocular pressure or ECD among the three groups after 6 months (P > 0.05). The photopic contrast sensitivity in Group C was statistically better than in Group A (P < 0.05). The scotopic ocular aberration in Group B was statistically greater compared to that in Group A (P < 0.05). The highest near-visual peaks were -0.06 logMAR at a -2.50 D (40 cm) in Group A, -0.07 logMAR at -3.00D (33 cm) in Group B, and -0.06 logMAR at -3.50 D (29 cm) in Group C. Statistically significant differences in near and intermediate visual acuities were observed among the three groups at -2.00 D (50 cm), -2.50 D (40 cm), -3.50 D (29 cm) and -4.00 D (25 cm) (P < 0.01). Conclusion : AcrySof® ReSTOR® SN6AD1 IOLs (+3.00 D) and SN6AD3 (+4.00 D) IOLs provided the best intermediate and near vision, respectively. Both intermediate and near vision were comparatively better in the eyes with AcrivaUD Reviol BB MFM 611 IOLs or BB MF 613 IOLs (+3.75 D).

2020 ◽  
pp. 112067212094020
Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Javier Martínez ◽  
Noemi Burguera ◽  
David P Piñero

Purpose: To identify the most sensitive visual performance metric for evaluating the pupil-dependency of a multifocal intraocular lens (MIOL) and to determine the pupil measurement method most correlated with such metric. Methods: Twenty-seven right eyes implanted with a MIOL were included in the analysis. Three pupil size measurements were obtained preoperatively and at 1 month after surgery with the Keratograph 5M system: photopic (PP), mesopic (MP), and the average from both (AP). Pupil was also measured with a rule (RP) under the same light conditions of postoperative visual performance measurements that included, corrected visual acuities (VA) at three distances (far, 67 cm and 40 cm), visual acuity (VADC) and contrast sensitivity defocus curves for optotype sizes of 0.3 logMAR (CSDC3) and 0.7 logMAR (CSDC7). Differences in visual performance were also analyzed for eyes with RP > 3 mm (Group A) and RP ⩽ 3 mm (Group B). Results: PP diameter decreased after surgery by 16% ( p = 0.001), whereas MP ( p = 0.013) and AP ( p = 0.008) decreased by 10%. The best agreement with RP was obtained for AP. Group B showed a trend to better performance than Group A for all the included metrics ( p > 0.05). From the three types of defocus curves, CSDC3 obtained generally highest statistical power for testing differences between groups. The strongest statistically significant correlations between pupil size and CSDC3 were obtained for RP and AP. Conclusion: The CSDC3 was the most sensitive metric to detect MIOL pupil-dependency. PR and AP were more correlated with CSDC3 than PP and MP.


2019 ◽  
Vol 13 (1) ◽  
pp. 15-22 ◽  
Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Ana Tauste ◽  
César Albarrán ◽  
Iñaki Basterra ◽  
...  

Objective:To evaluate the repeatability of the fast measurement of the visual acuity (VADC) and contrast sensitivity (CSDC) defocus curves with a new test as well as the agreement of measurements at far distance obtained with the Early Treatment Diabetic Retinopathy Study (ETDRS) chart and the ClinicCSF test for measuring Contrast Sensitivity Function (CSF).Method:Records from fifty-nine subjects implanted with Multifocal Intraocular Lenses (MIOLs) were retrieved from our database. VADC and CSDC were measured from +1.00 D to -4.00 D in 0.50 D steps. The agreement with the ETDRS and the CSF at far distance was assessed in comparison to the 0 D location of the VADC and the CSDC, respectively. The repeatability was evaluated in 34 subjects who consecutively repeated two measures.Results:Median Visual Acuity (VA) was -0.1 logMAR with the VADC at 0 D of defocus and 0 logMAR with the ETDRS (p>0.05). A total of 45.8% of eyes showed no differences between both tests and the difference was less than one line of VA in 96.6% of the eyes. The intrasubject repeatability was under one line of VA along all the defocus curve except for positive defocus levels. The CSDC showed the best agreement with the CSF for 18 cycles per degree. The CSDC was less repeatable than VADC. Mean time spent on completing the VADC and CSDC was 7.81 and 7.98 minutes, respectively.Conclusion:The VADC showed good agreement with the ETDRS and good repeatability despite the short testing time. In contrast, poorer repeatability was found for CSDC. Our method would facilitate the inclusion of VADC in clinical practice as it is a fast test, being also the first one including the measure of CSDC.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Tetsuro Oshika ◽  
Hiroyuki Arai ◽  
Yoshifumi Fujita ◽  
Mikio Inamura ◽  
Yasushi Inoue ◽  
...  

Abstract We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.


2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Shasha Gao ◽  
Tingyu Qin ◽  
Shengnan Wang ◽  
Yong Lu

Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL) in ciliary sulcus guided by ultrasound biomicroscopy (UBM).Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed.Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P<0.05). The differences in best corrected visual acuity (BCVA) and contrast sensitivity were not statistically significant (P>0.05).Conclusions.Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2018 ◽  
Vol 3 (1) ◽  
pp. e000139
Author(s):  
Lee Lenton

ObjectiveTo compare the performance of adults with multifocal intraocular lenses (MIOLs) in a realistic flight simulator with age-matched adults with monofocal intraocular lenses (IOLs).Methods and AnalysisTwenty-five adults ≥60 years with either bilateral MIOL or bilateral IOL implantation were enrolled. Visual function tests included visual acuity and contrast sensitivity under photopic and mesopic conditions, defocus curves and low luminance contrast sensitivity tests in the presence and absence of glare (Mesotest II), as well as halo size measurement using an app-based halometer (Aston halometer). Flight simulator performance was assessed in a fixed-based flight simulator (PS4.5). Subjects completed three simulated landing runs in both daytime and night-time conditions in a randomised order, including a series of visual tasks critical for safety.ResultsOf the 25 age-matched enrolled subjects, 13 had bilateral MIOLs and 12 had bilateral IOLs. Photopic and mesopic visual acuity or contrast sensitivity were not significantly different between the groups. Larger halo areas were seen in the MIOL group and Mesotest values were significantly worse in the MIOL group, both with and without glare. The defocus curves showed better uncorrected visual acuity at intermediate and near distances for the MIOL group. There were no significant differences regarding performance of the vision-related flight simulator tasks between both groups.ConclusionsThe performance of visually related flight simulator tasks was not significantly impaired in older adults with MIOLs compared with age-matched adults with monofocal IOLs. These findings suggest that MIOLs do not impair visual performance in a flight simulator.


2021 ◽  
Vol 14 (3) ◽  
pp. 356-365
Author(s):  
Farideh Doroodgar ◽  
◽  
Azad Sanginabadi ◽  
Farid Karimian ◽  
Sana Niazi ◽  
...  

AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses (MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients (282 eyes) with different MIOLs implantation. The Symfony (60 eyes), the ReSTOR (100 eyes), the AT LISAtri (60 eyes), and the PanOptix (62 eyes) intraocular lenses were evaluated in this prospective interventional study. The near, intermediate, and distant visual acuities, contrast sensitivity, and defocus curve were measured as valid criteria. To statistically analyze the results, we used the Statistical Package for Social Science software, the non-parametric Wilcoxon signed-rank t, the one-way analysis of variance and the Tukey's post-hoc test in our analysis. Moreover, we conducted a detailed literature search on the PubMed database in English about MIOLs, in total 59 studies were included in this review article. RESULTS: The four approaches did not show any significant difference in the best-corrected distance visual acuity (P>0.05). The defocus curves at the contrast of 100% showed that trifocal IOLs had better intermediate performance than the bifocal IOL (P<0.05). There were no statistically significant differences between AT LISAtri and PanOptix lenses for visual acuity at all distances. The eyes with PanOptix, Symfony, and AT LISAtri IOL showed better contrast sensitivity than those ReSTOR at spatial frequencies of 1, 3, and 6 cpd in photopic and mesopic conditions (P<0.001). CONCLUSION: All four groups of the multifocal lenses were satisfying in terms of distance and near vision. Also, the group of trifocal lenses led to satisfactory outcomes in intermediate vision, without degradation in quality of vision.


2014 ◽  
Vol 52 (196) ◽  
pp. 1010-1013
Author(s):  
Nanda Kumari Gurung ◽  
Prachand Gautam ◽  
Shanti Gurung ◽  
Binita Bhattarai

Introduction: Glaucoma is the second leading cause of blindness worldwide. Phacotrabeculectomyis a technique in which glaucoma and cataract surgery performed. Methods: Prospective study was carried out in the department of glaucoma at Lumbini Eye Institute, Bhairahawa.100 patients who underwent phacotrabeculectomy within a period of two years. Patients were divided into two groups those who received 5FU (n=47) and no antifibrotic agent (n= 53). Results: The age range was from 38 to 80 years; mean age of 62.97±9.14 SD. 55% were male and 45% were female.The postoperative IOP reduction in last follow- up group A was mean=13.08±1.57SD and mean=13.23±1.73SD in group B. This was statically significant with P <0.001. Bleb survival was almost similar in two groups 3.17(78.31%) in group A and 3.20 (78.93%) in group B. 85% visual acuity was improved in both groups. Conclusions: Phacotrabeculectomy and phacotrabeculectomy with inj. 5FU, both were equally effective surgical techniques in terms of visual acuity, IOP control and bleb survival.There was no significant statistical difference vis-à-vis the success of Phacotrabeculectomy using of either these two techniques.  Keywords: glaucoma; 5FU; intraocular pressure; phacotrabeculectomy.


2014 ◽  
Vol 95 (4) ◽  
pp. 515-519
Author(s):  
K S Ivonin

Aim. To analyze the causes for patients’ dissatisfaction with the results of multifocal intraocular lens implantation. Methods. The research is based on the results of cataract surgeries in 220 patients (50 patients were implanted multifocal refractive intraocular «M-flex» lens, 40 - multifocal intraocular «Gradiol» lens, 64 - multifocal intraocular «Accord» lens, 66 - monofocal intraocular lens). Pre-and post-operative examination included visual acuity test (with and without correction to near, far and moderate distances), determination of the nearest point of clear vision, contrast sensitivity study using the «Zebra» software, stereo vision test, pupil diameter measuring, refractometry, keratometry, binocular vision color tests, patient questioning. Pre-operative evaluation was performed 1 day prior to surgery. Post-operative observation was carried out 1 week, 1, 3, 6 and 12 months after the surgery. Results. No statistically significant difference (p 0.05) in uncorrected visual acuity at different light intensity - 102 lux and 416 lux - was found between the groups with different types of multifocal intraocular lenses. In groups with multifocal intraocular lenses light side effects were observed in 46-52.5% of patients. However, there was no link between the light side effects and patients’ satisfaction with results of the surgery. Reduction of spatial contrast sensitivity parameters was registered in all groups of multifocal intraocular lenses patients compared to patients with monofocal intraocular lenses (p 0.05). According to the survey results, 92.5 to 94% of patients with multifocal intraocular lenses did not report decreased visual acuity on moderate distance. Conclusion. The most important reason for patients’ dissatisfaction with the results of the multifocal intraocular lenses implanting was the reduction of spatial-contrast sensitivity parameters. Bilateral multifocal intraocular lenses implanting improved the contrast ratio.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Hirotaka Tanabe ◽  
Hitoshi Tabuchi ◽  
Tomohiro Shojo ◽  
Tomofusa Yamauchi ◽  
Kosuke Takase

Abstract To compare the visual performance of a monofocal intraocular lens (IOL) (ZCB00) and a multifocal IOL (ZMB00) of the same material and basic design, we evaluated postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZCB00 or ZMB00 implantation from December 13, 2010, to July 29, 2019, with the right and left lenses implanted within 3 months of each other. The study enrolled 2,230 eyes of 1,115 patients. The monofocal group comprised 904 eyes of 452 patients (72.3 ± 6.8 years; females/males, 268/184), and the multifocal group comprised 1,326 eyes of 663 patients (67.0 ± 7.8 years; females/males, 518/145). Contrast sensitivity (4.0/2.5/1.6/1.0/0.7 degrees), contrast sensitivity with glare (1.6/1.0/0.7 degrees), and the VFQ-25 score for driving at night were significantly better in the monofocal group (p < 0.00068, Wald test). Uncorrected intermediate/near visual acuity and near spectacle independence were significantly better in the multifocal group (p < 0.00068, Wald test). The two IOL groups had different characteristics in terms of contrast sensitivity, night-time driving, uncorrected intermediate/near visual acuity and near spectacle independence.