scholarly journals Compliance as an Integral Part of the Dry Eye Syndrome Prevention Using Silicone Hydrogel Contact Lenses

2016 ◽  
Vol 23 (4) ◽  
pp. 201647
Author(s):  
Rimma Skrypnyk ◽  
Olga Selezneva

The probability of dry eye syndrome (DES) in the patients using the Silicone-Hydrogel Contact Lenses is examined in many researches. Therefore, adhering to clinical recommendations is an important factor for DES prevention. The urgent issue is also a comprehensive assessment of functional parameters as pathogenetic base of DES.The objective of the research was tostudy DES development depending on compliance of silicone hydrogel contact lenses users.Matherials and methods. 97 patients (194 eyes) were included into the research. They formed 2 groups: group I with incomplete compliance (36 persons) and group II with complete compliance (61 persons). All the patients underwent the Norn’s test, Schirmer’s test, Jones test, tear film stability was defined. The probability of the dry eye syndrome development due to the subjective signs was also analysed.Results. The reliable decrease in the total (р<0.05) and basale lacrimation (р<0.05) indexes, the increase in osmolarity (р<0.05) and decrease in tear film stability (р<0.05) were detected in the patients who did not follow the clinical guidance during the Silicone-Hydrogel Contact Lenses wearing. In the same group the higher risk of dry eye syndrome development was verified (р<0.05).Conclusion. Compliance disorder in the patients using Silicone-Hydrogel Contact Lenses was found to induce the reliable decrease in total and basale lacrimation, increase in osmolarity and tear stability disorder. All of this factors increase the risk of dry eye syndrome.

2016 ◽  
Vol 95 (3) ◽  
pp. e230-e235 ◽  
Author(s):  
Ki Won Jin ◽  
Jin Woo Ro ◽  
Young Joo Shin ◽  
Joon Young Hyon ◽  
Won Ryang Wee ◽  
...  

Reflection ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 30-36
Author(s):  
O.V. Kolenko ◽  
◽  
Y.V. Kutuzova ◽  
I.V. Dutchin ◽  
E.L. Sorokin ◽  
...  

Aim. Comparative analysis of the effectiveness of keratotopography methods and classical Norn’s test in assessing the stability of the tear film (TF) in patients with myopia before photorefractive surgery. Methods. The study involved 26 patients. All of them were planned for keratorefractive surgery to correct myopic refraction and astigmatism. Their age averaged 32.5±14.5 years (18-47 years). The stability of pre-corneal tear film was assessed using computed keratotopography and Norn’s test - the tear film rupture time (TFRT) was determined. A standard questionnaire was also used to assess the severity of symptoms of dry eye syndrome (DES). A comparison was made of the indicators of tear film, stability obtained by the methods of keratotopography and Norn’s test, with their subsequent comparison with the data of the questionnaire. Results. In 17 patients (65.4 %), TFRT index corresponded to the age norm. In the remaining 9 people (34.6 %), indicators of tear film stability were reduced both by keratotopography (12±4 sec) and by Norn’s test (13.5± 4.5 sec), and there were also subjective signs of dry eye syndrome according to questionnaire data. The data turned out to be comparable. Conclusion. The incidence of impaired stability of the TF and subjective manifestations of DES among patients planned for keratorefractive surgery for myopia and myopic astigmatism was significant and, according to our data, made 34.6 %. To prevent complicated postoperative course of photorefractive surgery, it is necessary to assess the condition of the ocular surface immediately before refractive surgery, to identify the risk group for DES development. Key words: dry eye syndrome; tear film; keratotopography; Norn’s test; tear film rupture time.


2014 ◽  
Vol 5 (2) ◽  
pp. 25-29
Author(s):  
Nataliya Nikolayevna Sadovnikova ◽  
Galiya Fettyakhovna Kutusheva

To assess the effect of menopausal syndrome manifestations in the manifestation of «dry eye» examined 63 women . All examined the condition of the ocular surface, tear film stability, severity of subjective discomfort . Revealed that the dry eye syndrome in postmenopausal women occurs predominantly in the mild and moderate forms, with the severity of clinical and functional features of dry eye syndrome significantly correlated with severity of menopausal symptoms .


2020 ◽  
Vol 36 (1) ◽  
Author(s):  
Nabila Zulfiqar ◽  
Muhammad Sufyan Aneeq Ansari ◽  
Khurram Nafees ◽  
Rabia Nawaz ◽  
Manzra Shaheen

Purpose:  To determine the frequency of Dry eye in Glaucoma patients using topical anti-glaucoma therapy. Study Design:  Descriptive Observational study. Place and Duration of Study:  Study was conducted in outpatient department of Fatima Memorial Hospital Shadman, Lahore, from October 2016 to February 2017. Material & Methods:  In this study, 61 diagnosed cases of glaucoma were included. Patients with significant dermatological problems that may be associated with dry eye such as rosacea and blepharitis were excluded from the study. The individuals were assessed by consultant Ophthalmologist for Dry eye syndrome having symptoms of stinging and burning sensations itching, watering, irritation, due to regular use of topical anti-glaucoma drugs. A written consent was taken from every patient before the test. The ocular surfaces of the patients were evaluated using Tear film break-up time test and Basal Schrimer’s test. Patients having TBUT less than 11 seconds were categorized as having dry eye. The degree of dryness was categorized as mild, moderate and sever Dry eye. Results:  Among 61 patients of glaucoma using topical anti-glaucoma therapy, 22 (36.1%) were male and 39 (63.9%) were female. Mean age of the patients was 50.76 ± 15.67 years. On the basis of Tear film Break-up time test, 49 (81%) patients had Tear Break-up time less than 10 seconds and 12 (19%) patients were normal. On the basis of Schrimer`s test 51 (83.66%) patients had Dry eye. Conclusion:  Topical use of anti-glaucoma therapy affects tear film stability and its functions leading to Dry eye syndrome.


2021 ◽  
Vol 21 (4) ◽  
pp. 200-204
Author(s):  
V.V. Brzheskiy ◽  
◽  
E.L. Efimova ◽  
M.A. Kopylova ◽  
P.V. Kocharina ◽  
...  

Aim: to study the changes in the critical parameters of tear film stability and autorefractometry in patients with mild dry eye syndrome (DES) after instilling artificial tear products of different viscosity. Patients and Methods: thirty patients aged 23–70 with mild bilateral DES were examined using the Visionix VX120+Dry Eye multi-diagnostic unit equipped with the TF-Scan to fix and assess tear film stability and tear breakup time (TBUT). The critical refraction and tear film parameters were evaluated by keratometry, corneal topography, TBUT, and tear meniscus height measurements. Next, an artificial tear product was instilled, i.e., group 1 (14 patients, 28 eyes) received a 0.15% sodium hyaluronate-based preparation, and group 2 (16 patients, 32 eyes) received a 0.4% sodium hyaluronate-based preparation. The examination was repeated after 30 sec and 5 min. Controls were seven healthy individuals (14 eyes). Results: in DES, breaks in the tear film appeared earlier and affected greater corneal surface area. A "Destabilized tear film area" parameter of the Visionix VX120+Dry Eye contributed significantly to the knowledge of tear film functionality, thereby empowering the diagnostic armamentarium in DES. As early as 30 sec after instillation of both artificial tear preparations, breakup-free time tended to increase, while the area of tear film destabilization tended to reduce. After 5 min, this trend continued to increase, particularly after instilling 0.15% sodium hyaluronate-based preparation. At the same time, changes in keratometry readings (i.e., sphere and cylinder) and astigmatism axis orientation were reported. Corneal refractive power (more in the flattest axis) increased, in particular, after the instillations of 0.15% hyaluronic acid. The range of changes was 0.00–0.75 D for the sphere power, 0.00–0.50 D for the cylinder power, and 0–69 degrees for astigmatism axis orientation. Conclusions: our findings with the Visionix VX120+Dry Eye multi-diagnostic unit demonstrate a significant variation of autorefractometry readings in DES depending on the extent of ocular surface hydration. These phenomena raise questions about the accuracy of autorefractometry readings. Therefore, autorefractometry should be performed after normalizing tear film volume and stability. Keywords: dry eye syndrome, Visionix®, autorefractometry, tearscopy, the effect of artificial tears on results. For citation: Brzheskiy V.V., Efimova E.L., Kopylova M.A. et al. Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity. Russian Journal of Clinical Ophthalmology. 2021;21(4):200–204 (in Russ.). DOI: 10.32364/2311-7729-2021-21-4-200-204.


The Eye ◽  
2019 ◽  
Vol 127 (2019-3) ◽  
pp. 34-38
Author(s):  
Artur Mits

Topicality. In recent years, dry eye syndrome has become increasingly important in clinical practice. Disturbance of the wettability of the eye surface occurs due to external factors influence, one of which are contact lenses. The review presents the literature data analysis covering possible impact of contact lenses made of different materials (hydrogel, silicone hydrogel, soft and rigid gas permeable) on the development of dry eye symptoms, as well as the role of tear substitutes use when wearing contact lenses. Due to agreat variety of different studies on this topic, the literature review on the tear substitutes instillation when wearing contact lenses in patients with dry eye syndrome is relevant and crucial for doctors in outpatient departments. Conclusion. The research has shown that, it is possible to identify unmodifiable and modifiable risk factors for dry eye syndrome with reliable and probable factors. In addition, the therapeutic use of HYLO-COMOD and PARIN-POS is accompanied by minimum possible negative side effects and their use can increase the amount of tear film, as well as reduce the severity of eye discomfort.


2018 ◽  
Vol 10 (1) ◽  
pp. 32
Author(s):  
Bariah Mohd-Ali ◽  
MohamadHanif Hajar-Maidin ◽  
Asmah Ahmad ◽  
Zainora Mohammed ◽  
Jamaluddin Mohamed

2020 ◽  
Vol Volume 14 ◽  
pp. 1153-1159 ◽  
Author(s):  
Pedro Molina-Solana ◽  
Francisco de Borja Domínguez-Serrano ◽  
Antonio Manuel Garrido-Hermosilla ◽  
Jesús Montero-Iruzubieta ◽  
Ana Fernández-Palacín ◽  
...  

2017 ◽  
Vol Volume 11 ◽  
pp. 1883-1889 ◽  
Author(s):  
Gail Torkildsen ◽  
Mile Brujic ◽  
Michael Cooper ◽  
Paul Karpecki ◽  
Parag Majmudar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document