Optimal image segmentation protocol for 3D printing of aortic dissection through open-source software

Author(s):  
Chia-An Wu ◽  
Andrew Squelch ◽  
Zhonghua Sun

Aim: To determine the optimal image segmentation protocol that minimizes the amount of manual intervention and correction required while extracting 3D model geometries suitable for 3D printing of aortic dissection (AD) using open-source software. Materials & methods: Computed tomography images of two type B AD cases were selected with images segmented using a 3D Slicer to create a hollow model containing the aortic wall and intimal tear. A workflow composed of filters, lumen extraction and outer surface creation was developed. Results & conclusion: The average difference in measurements at 14 anatomical locations between the Standard Tessellation Language file and the computed tomography image for cases 1 and 2 were 0.29 and 0.32 mm, respectively. The workflow for the image segmentation of type B AD was able to produce a high-accuracy 3D-printed model in a short time through open-source software.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mohammad Amin Abazari ◽  
Deniz Rafieianzab ◽  
M. Soltani ◽  
Mona Alimohammadi

AbstractAortic dissection (AD) is one of the fatal and complex conditions. Since there is a lack of a specific treatment guideline for type-B AD, a better understanding of patient-specific hemodynamics and therapy outcomes can potentially control the progression of the disease and aid in the clinical decision-making process. In this work, a patient-specific geometry of type-B AD is reconstructed from computed tomography images, and a numerical simulation using personalised computational fluid dynamics (CFD) with three-element Windkessel model boundary condition at each outlet is implemented. According to the physiological response of beta-blockers to the reduction of left ventricular contractions, three case studies with different heart rates are created. Several hemodynamic features, including time-averaged wall shear stress (TAWSS), highly oscillatory, low magnitude shear (HOLMES), and flow pattern are investigated and compared between each case. Results show that decreasing TAWSS, which is caused by the reduction of the velocity gradient, prevents vessel wall at entry tear from rupture. Additionally, with the increase in HOLMES value at distal false lumen, calcification and plaque formation in the moderate and regular-heart rate cases are successfully controlled. This work demonstrates how CFD methods with non-invasive hemodynamic metrics can be developed to predict the hemodynamic changes before medication or other invasive operations. These consequences can be a powerful framework for clinicians and surgical communities to improve their diagnostic and pre-procedural planning.


2015 ◽  
Vol 117 (18) ◽  
pp. 183102 ◽  
Author(s):  
Arjun S. Kumar ◽  
Pratiti Mandal ◽  
Yongjie Zhang ◽  
Shawn Litster

Author(s):  
Chia-An Wu ◽  
Andrew Squelch ◽  
Zhonghua Sun

Aim: To determine a printing material that has both elastic property and radiology equivalence close to real aorta for simulation of endovascular stent graft repair of aortic dissection. Background: With the rapid development of three-dimensional (3D) printing technology, a patient-specific 3D printed model is able to help surgeons to make better treatment plan for Type B aortic dissection patients. However, the radiological properties of most 3D printing materials have not been well characterized. This study aims to investigate the appropriate materials for printing human aorta with mechanical and radiological properties similar to the real aortic computed tomography (CT) attenuation. Objective: Quantitative assessment of CT attenuation of different materials used in 3D printed models of aortic dissection for developing patient-specific 3D printed aorta models to simulate type B aortic dissection. Method: A 25-mm length of aorta model was segmented from a patient’s image dataset with diagnosis of type B aortic dissection. Four different elastic commercial 3D printing materials, namely Agilus A40 and A50, Visijet CE-NT A30 and A70 were selected and printed with different hardness. Totally four models were printed out and conducted CT scanned twice on a 192-slice CT scanner using the standard aortic CT angiography protocol, with and without contrast inside the lumen.Five reference points with region of interest (ROI) of 1.77 mm2 were selected at the aortic wall and intimal flap and their Hounsfield units (HU) were measured and compared with the CT attenuation of original CT images. The comparison between the patient’s aorta and models was performed through a paired-sample t-test to determine if there is any significant difference. Result: The mean CT attenuation of aortic wall of the original CT images was 80.7 HU. Analysis of images without using contrast medium showed that the material of Agilus A50 produced the mean CT attenuation of 82.6 HU, which is similar to that of original CT images. The CT attenuation measured at images acquired with other three materials was significantly lower than that of original images (p<0.05). After adding contrast medium, Visijet CE-NT A30 had an average CT attenuation of 90.6 HU, which is close to that of the original images with statistically significant difference (p>0.05). In contrast, the CT attenuation measured at images acquired with other three materials (Agilus A40, A50 and Visiject CE-NT A70) was 129 HU, 135 HU and 129.6 HU, respectively, which is significantly higher than that of original CT images (p<0.05). Conclusion: Both Visijet CE-NT and Agilus have tensile strength and elongation close to real patient’s tissue properties producing similar CT attenuation. Visijet CE-NT A30 is considered the appropriate material for printing aorta to simulate contrast-enhanced CT imaging of type B aortic dissection. Due to lack of body phantom in the experiments, further research with simulation of realistic anatomical body environment should be conducted.


2019 ◽  
Vol 61 (1) ◽  
pp. 136-144
Author(s):  
Tetsuhiro Otsuka ◽  
Eijun Sueyoshi ◽  
Yutaro Tasaki ◽  
Masataka Uetani

Background The relationships between the computed tomography (CT) findings and outcomes of patients with ruptured type B aortic dissection have not been clarified. Purpose To evaluate the initial CT findings of patients with ruptured type B aortic dissection and investigate the relationships between the initial CT findings and in-hospital mortality. Material and Methods This study was approved by the institutional review board. Thirty-three patients were diagnosed with ruptured Stanford type B aortic dissection at our hospital between 2007 and 2016 (21 men, 12 women; mean age = 76.1±10.7 years). We retrospectively evaluated the initial CT findings of ruptured type B aortic dissection and the relationships between clinical factors and in-hospital mortality using logistic regression analysis. Results Type B aortic dissections ruptured in the acute and chronic phases in 23 and 10 patients, respectively. The initial CT images showed various findings, including an open false lumen (58%), arch involvement (88%), hematomas in the pleural space (55%), hematomas in the pericardial space (18%), and the extravasation of vascular contrast material (12%). The mean maximum diameter of the affected aorta was 49.5 ± 16.1 mm. Among the 33 patients, 14 died at hospital. Female gender (hazard ratio = 10.284; 95% confidence interval [CI] = 1.61–65.54; P = 0.0136) and the presence of a hematoma in the pleural space (hazard ratio = 6.803; 95% CI = 1.07–43.24; P = 0.0421) were found to be predictors of in-hospital mortality. Conclusion Female gender and the presence of a hematoma in the pleural space are significant predictors of in-hospital mortality in patients with ruptured type B aortic dissection.