scholarly journals A case of atrioventricular junction ablation and permanent left bundle branch pacing for patient with refractory atrial fibrillation and hypertrophic cardiomyopathy

Author(s):  
Ning Zhang ◽  
Shan Liu ◽  
Shou Zhang ◽  
Yan Wei ◽  
Le Xie ◽  
...  

Atrioventricular node ablation (AVNA) combined with His bundle pacing (HBP) are feasible, safe, and effective in patients with refractory atrial fibrillation (AF), however, the pacing parameters of sensing and capture threshold maybe sometimes unsatisfactory. Left bundle branch pacing (LBBP) provides obvious advantage in patients with conduction diseases at the distal His bundle for its better sensing, a lower and more stable capture threshold. Among hypertrophic cardiomyopathy (HCM) patients, AF is a common sustained arrhythmia, primarily caused by left atrial dilatation and remodeling. Few is known about the feasibility of electrophysiological performance, safety and clinical effectiveness of atrioventricular junction ablation (AVJA) combined with LBBP in patient with refractory AF and HCM. Here, we report a case of a 56-year-old woman suffering from refractory AF and HCM, however HBP was failed for its unsatisfactory sensing, a high and unstable capture threshold for her, therefore, ablation and LBBB were accepted by her to achieve better rate control. Improvement in symptoms, quality of life, and exercise capacity has been observed during the 1.5-year follow-up. To our knowledge, our case originally confirmed that the combination of AVJA and LBBP, without the defect of AVNA combined with HBP, is a better strategy with feasibility and safety for refractory AF patients with comorbidity of HCM, additionally, it may make LBBP more applicable and valuable among patients suffering from HCM meanwhile pace maker treatments are essential.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
C Chaumont ◽  
N Auquier ◽  
A Mirolo ◽  
E Popescu ◽  
A Milhem ◽  
...  

Abstract Introduction Ventricular rate control is essential in the management of atrial fibrillation. Atrioventricular node ablation (AVNA) and ventricular pacing can be an effective option when pharmacological rate control is insufficient. However, right ventricular pacing (RVP) induces ventricular desynchronization in patients with normal QRS and increases the risk of heart failure on long term. His bundle pacing (HBP) is a physiological alternative to RVP. Observational studies have demonstrated the feasibility of HBP but there is still very limited data about the feasibility of AVNA after HBP. Purpose To evaluate feasibility and safety of HBP followed by AVNA in patients with non-controlled atrial arrhythmia. Methods We included in three hospitals between september 2017 and december 2019 all patients who underwent AVNA for non-controlled atrial arrhythmia after permanent His bundle pacing. No back-up right ventricular lead was implanted. AVNA procedures were performed with 8 mm-tip ablation catheter. Acute HBP threshold increase during AVNA was defined as a threshold elevation >1V. His bundle capture (HBC) thresholds were recorded at 3 months follow-up. Results AVNA after HBP lead implantation was performed in 45 patients. HBP and AVNA were performed simultaneously during the same procedure in 10. AVNA was successful in 32 of 45 patients (71%). Modulation of the AV node conduction was obtained in 7 patients (16%). The mean procedure duration was 42±24min, and mean fluoroscopy duration was 6.4±8min. A mean number of 7.7±9.9 RF applications (347±483 sec) were delivered to obtain complete / incomplete AV block. Acute HBC threshold increase occurred in 8 patients (18%) with return to baseline value at day 1 in 5 patients. There was no lead dislodgment during the AVNA procedures. Mean HBC threshold at implant was 1.26±[email protected] and slightly increased at 3 months follow-up (1.34±[email protected]). AV node re-conduction was observed in 5 patients (16% of the successful procedures) with a second successful ablation procedure in 4 patients. No ventricular lead revision was required during the follow-up period. The baseline native QRS duration was 102±21 ms and the paced QRS duration was 107±18 ms. Conclusion AVNA combined with HBP for non-controlled atrial arrhythmia is feasible and does not compromise HBC but seems technically difficult with significant AV nodal re-conduction rate. The presence of a back-up right ventricular lead could have changed our results and therefore would require further evaluation. Unipolar HBP after AV node ablation Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 30 (4) ◽  
pp. 634-638
Author(s):  
Catalin Pestrea ◽  
Alexandra Gherghina ◽  
Irina Pintilie ◽  
Florin Ortan

Atrial fibrillation (AF) is a serious cause of morbidity and mortality in the general population, with an increasing prevalence with the improvement in diagnosis. The best current treatment approach is catheter ablation (mainly isolation of the pulmonary veins), but this is ineffective in permanent atrial fi brillation. Rate control is frequently mandatory in these patients and the most effective technique is atrioventricular node ablation. But, since this procedure renders the patient pacemaker dependent, one should be very cautious with the pacing mode selected for long-term pacing. We present the case of a 45 year-old male with permanent atrial fi brillation and drug-refractory rapid ventricular rate and tachycardia-induced cardiomyopathy, who underwent catheter ablation of the atrioventricular node and permanent selective His bundle pacing. Following the procedure, the patient went from a rapid, irregular rhythm to a controlled, regular rhythm without a change in QRS morphology. The follow-up after three months showed near complete recovery of the left ventricle and the disappearance of heart failure symptoms.


Author(s):  
Lian-Yu Lin ◽  
Ting-Tse Lin ◽  
Jien-Jiun Chen ◽  
Jiunn-Lee Lin ◽  
Shoei K. Stephen Huang

scholarly journals POSTERS (2)96CONTINUOUS VERSUS INTERMITTENT MONITORING FOR DETECTION OF SUBCLINICAL ATRIAL FIBRILLATION IN HIGH-RISK PATIENTS97HIGH DAY-TO-DAY INTRA-INDIVIDUAL REPRODUCIBILITY OF THE HEART RATE RESPONSE TO EXERCISE IN THE UK BIOBANK DATA98USE OF NOVEL GLOBAL ULTRASOUND IMAGING AND CONTINUEOUS DIPOLE DENSITY MAPPING TO GUIDE ABLATION IN MACRO-REENTRANT TACHYCARDIAS99ANTICOAGULATION AND THE RISK OF COMPLICATIONS IN PATIENTS UNDERGOING VT AND PVC ABLATION100NON-SUSTAINED VENTRICULAR TACHYCARDIA FREQUENTLY PRECEDES CARDIAC ARREST IN PATIENTS WITH BRUGADA SYNDROME101USING HIGH PRECISION HAEMODYNAMIC MEASUREMENTS TO ASSESS DIFFERENCES IN AV OPTIMUM BETWEEN DIFFERENT LEFT VENTRICULAR LEAD POSITIONS IN BIVENTRICULAR PACING102CAN WE PREDICT MEDIUM TERM MORTALITY FROM TRANSVENOUS LEAD EXTRACTION PRE-OPERATIVELY?103PREVENTION OF UNECESSARY ADMISSIONS IN ATRIAL FIBRILLATION104EPICARDIAL CATHETER ABLATION FOR VENTRICULAR TACHYCARDIA ON UNINTERRUPTED WARFARIN: A SAFE APPROACH?105HOW WELL DOES THE NATIONAL INSTITUTE OF CLINICAL EXCELLENCE (NICE) GUIDENCE ON TRANSIENT LOSS OF CONSCIOUSNESS (T-LoC) WORK IN A REAL WORLD? AN AUDIT OF THE SECOND STAGE SPECIALIST CARDIOVASCULAT ASSESSMENT AND DIAGNOSIS106DETECTION OF ATRIAL FIBRILLATION IN COMMUNITY LOCATIONS USING NOVEL TECHNOLOGY'S AS A METHOD OF STROKE PREVENTION IN THE OVER 65'S ASYMPTOMATIC POPULATION - SHOULD IT BECOME STANDARD PRACTISE?107HIGH-DOSE ISOPRENALINE INFUSION AS A METHOD OF INDUCTION OF ATRIAL FIBRILLATION: A MULTI-CENTRE, PLACEBO CONTROLLED CLINICAL TRIAL IN PATIENTS WITH VARYING ARRHYTHMIC RISK108PACEMAKER COMPLICATIONS IN A DISTRICT GENERAL HOSPITAL109CARDIAC RESYNCHRONISATION THERAPY: A TRADE-OFF BETWEEN LEFT VENTRICULAR VOLTAGE OUTPUT AND EJECTION FRACTION?110RAPID DETERIORATION IN LEFT VENTRICULAR FUNCTION AND ACUTE HEART FAILURE AFTER DUAL CHAMBER PACEMAKER INSERTION WITH RESOLUTION FOLLOWING BIVENTRICULAR PACING111LOCALLY PERSONALISED ATRIAL ELECTROPHYSIOLOGY MODELS FROM PENTARAY CATHETER MEASUREMENTS112EVALUATION OF SUBCUTANEOUS ICD VERSUS TRANSVENOUS ICD- A PROPENSITY MATCHED COST-EFFICACY ANALYSIS OF COMPLICATIONS & OUTCOMES113LOCALISING DRIVERS USING ORGANISATIONAL INDEX IN CONTACT MAPPING OF HUMAN PERSISTENT ATRIAL FIBRILLATION114RISK FACTORS FOR SUDDEN CARDIAC DEATH IN PAEDIATRIC HYPERTROPHIC CARDIOMYOPATHY: A SYSTEMATIC REVIEW AND META-ANALYSIS115EFFECT OF CATHETER STABILITY AND CONTACT FORCE ON VISITAG DENSITY DURING PULMONARY VEIN ISOLATION116HEPATIC CAPSULE ENHANCEMENT IS COMMONLY SEEN DURING MR-GUIDED ABLATION OF ATRIAL FLUTTER: A MECHANISTIC INSIGHT INTO PROCEDURAL PAIN117DOES HIGHER CONTACT FORCE IMPAIR LESION FORMATION AT THE CAVOTRICUSPID ISTHMUS? INSIGHTS FROM MR-GUIDED ABLATION OF ATRIAL FLUTTER118CLINICAL CHARACTERISATION OF A MALIGNANT SCN5A MUTATION IN CHILDHOOD119RADIOFREQUENCY ASSOCIATED VENTRICULAR FIBRILLATION120CONTRACTILE RESERVE EXPRESSED AS SYSTOLIC VELOCITY DOES NOT PREDICT RESPONSE TO CRT121DAY-CASE DEVICES - A RETROSPECTIVE STUDY USING PATIENT CODING DATA122PATIENTS UNDERGOING SVT ABLATION HAVE A HIGH INCIDENCE OF SECONDARY ARRHYTHMIA ON FOLLOW UP: IMPLICATIONS FOR PRE-PROCEDURE COUNSELLING123PROGNOSTIC ROLE OF HAEMOGLOBINN AND RED BLOOD CELL DITRIBUTION WIDTH IN PATIENTS WITH HEART FAILURE UNDERGOING CARDIAC RESYNCHRONIZATION THERAPY124REMOTE MONITORING AND FOLLOW UP DEVICES125A 20-YEAR, SINGLE-CENTRE EXPERIENCE OF IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICD) IN CHILDREN: TIME TO CONSIDER THE SUBCUTANEOUS ICD?126EXPERIENCE OF MAGNETIC REASONANCE IMAGING (MEI) IN PATIENTS WITH MRI CONDITIONAL DEVICES127THE SINUS BRADYCARDIA SEEN IN ATHLETES IS NOT CAUSED BY ENHANCED VAGAL TONE BUT INSTEAD REFLECTS INTRINSIC CHANGES IN THE SINUS NODE REVEALED BY I (F) BLOCKADE128SUCCESSFUL DAY-CASE PACEMAKER IMPLANTATION - AN EIGHT YEAR SINGLE-CENTRE EXPERIENCE129LEFT VENTRICULAR INDEX MASS ASSOCIATED WITH ESC HYPERTROPHIC CARDIOMYOPATHY RISK SCORE IN PATIENTS WITH ICDs: A TERTIARY CENTRE HCM REGISTRY130A DGH EXPERIENCE OF DAY-CASE CARDIAC PACEMAKER IMPLANTATION131IS PRE-PROCEDURAL FASTING A NECESSITY FOR SAFE PACEMAKER IMPLANTATION?

EP Europace ◽  
2016 ◽  
Vol 18 (suppl 2) ◽  
pp. ii36-ii47
Author(s):  
T. Philippsen ◽  
M. Orini ◽  
C.A. Martin ◽  
E. Volkova ◽  
J.O.M. Ormerod ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Ciesielski ◽  
A Slawuta ◽  
A Zabek ◽  
K Boczar ◽  
B Malecka ◽  
...  

Abstract   A single-chamber ICD is a standard method for primary SCD prophylaxis. In patients with chronic atrial fibrillation it does not contribute to the regularization of heart rate, which is crucial for proper treatment. Moreover, to avoid the deleterious effect of right ventricular pacing only minority of the patients with single chamber ICD get the appropriate, recommended dose of beta-blockers. The aim of our study was to assess the efficacy of direct His-bundle pacing in a population of patients with congestive heart failure and chronic atrial fibrillation using upgrade from single chamber to dual-chamber ICD and atrial channel to perform the His-bundle pacing Methods The study population included 39 patients (37 men, 2 women) aged 67.2±9.3 years, with CHF and chronic AF implanted primarily with single chamber ICD with established pharmacotherapy and stable clinical status. Results The echocardiography measurements at baseline and during follow-up were presented in the table: During short period (3–6 months) of follow-up the mean values of EF and LV dimensions significantly improved. This was also accompanied by functional status improvement. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The physiological pacing contributes to better pharmacotherapy. Funding Acknowledgement Type of funding source: None


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S216
Author(s):  
Mohita Singh ◽  
Lisa R. Salberg ◽  
Ellen Kornkven ◽  
Aslan Turer ◽  
Khadyoth Nanneboyina ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Karapet Davtyan ◽  
Victoria Shatakhtsyan ◽  
Hermine Poghosyan ◽  
Alexandr Deev ◽  
Alexey Tarasov ◽  
...  

Introduction. While several studies have compared the radiofrequency current (RFC) and cryoablation for the treatment of patients with atrial fibrillation (AF), no study has monitored the long-term outcomes with the usage of implantable loop recorders (ILRs). Methods. We enrolled 89 consecutive patients with nonvalvular paroxysmal AF (N=44 for RFC and N=45 for cryoballoon). The primary efficacy end point was the assessment of effectiveness for each group (RFC versus cryoballoon) when examining freedom from arrhythmia by monitoring with ECG, Holter, and implantable loop recoder (ILR). The primary safety end point compared rates of adverse events between both groups. The secondary efficacy end point examined the duration of the postablation blanking period from ILR retrieved data. Results. The mean age of the study population was 56.6±10.2 years, and the follow-up duration was 12 months. There were no differences in baseline patient characteristics between groups. At 12 months, the absolute effectiveness (measured by ILR) was 65.9% in the RFC group and 51.1% in the cryoballoon group (OR = 1.85; 95% CI: 0.79–4.35; p=0.157), and the clinical effectiveness (measured by ECG and Holter) was 81.8% in the RFC group and 55.6% in the cryoballoon group (OR = 3.6; 95% CI: 1.37–9.46; p=0.008). There was no difference in safety between both groups. Asymptomatic episodes were significantly more present in the RFC group as measured by ILRs (p<0.010). In cryoballoon group, arrhythmia episodes were recorded equally irrespective of the follow-up method (i.e., ECG and Holter versus ILR (p>0.010)). The blanking period does not seem to be as important in cryoballoon as compared to RFC. Conclusion. RFC and cryoballoon ablation had similar absolute effectiveness at 12 months. ECG and Holter were effective when assessing the efficacy of the cryoballoon ablation; however, in the RFC group, ILR was necessary to accurately assess long-term efficacy.


2018 ◽  
Vol 88 (2) ◽  
Author(s):  
Stefano Fumagalli ◽  
Serena Boni ◽  
Simone Pupo ◽  
Marta Migliorini ◽  
Irene Marozzi ◽  
...  

Atrial fibrillation (AF) is the most frequent arrhythmia in elderly people. Findings derived from clinical trials seem to demonstrate that a rate-control strategy of AF in aged patients improves prognosis if compared to a rhythm-control one. However, epidemiological studies concordantly show that the arrhythmia is associated to increased hospitalization and mortality rates. In last years, the proportion of patients admitted to hospital for AF has progressively increased; this trend is observed in subjects >75 and >85 years, while no change was found in younger cohorts. Importantly, in aged individuals, probably because of the loss of atrial activity, the increase of heart rate and the irregularity of RR intervals, AF begins a vicious cycle, leading from heart failure, through the compromise of functional and neurocognitive status, to overt disability, dementia and increased mortality. Evidence specifically aimed at clarifying the effects of arrhythmia management on outcomes characteristic of aged people is completely lacking. In the elderly, the question regarding the effects of a rate- or a rhythm-control strategy of AF should be considered as an aspect of a more complex strategy, addressed to reduce disability and hospitalizations, and to improve quality of life and survival.


Sign in / Sign up

Export Citation Format

Share Document