scholarly journals Numerical analysis of mixed convection in pulsating flow for a horizontal channel with a cavity heated from below

2016 ◽  
Vol 20 (1) ◽  
pp. 35-44 ◽  
Author(s):  
Fatih Selimefendigil

In this study, a channel with a cavity heated from below is numerically investigated for the mixed convection case in pulsating flow for a range of Richardson numbers (Ri=0.1, 1, 10, 100) at Reynolds number of 50 in the laminar flow regime. At the inlet of the channel, pulsating velocity is imposed for Strouhal numbers between 0.1 to 1 and velocity amplitude ratio between 0.3 to 0.9. The effect of the pulsation frequency, amplitude and Richardson number on the heat transfer enhancement is numerically analyzed. The results are presented in terms of streamlines, isotherm plots and averaged Nusselt number plots. FFT plots for the Nusselt number response to single sinusoidal velocity forcing at the inlet and nonlinearity in the response is also provided.

Author(s):  
Akand W. Islam ◽  
Muhammad A. R. Sharif ◽  
Eric S. Carlson

Laminar mixed convection characteristics in a square cavity with an isothermally heated square blockage inside have been investigated numerically using the finite volume method of the ANSYS FLUENT commercial CFD code. Various different blockage sizes and concentric and eccentric placement of the blockage inside the cavity have been considered. The blockage is maintained at a hot temperature, Th, and four surfaces of the cavity (including the lid) are maintained at a cold temperature, Tc, under all circumstances. The physical problem is represented mathematically by sets of governing conservation equations of mass, momentum, and energy. The geometrical and flow parameters for the problem are the blockage ratio (B), the blockage placement eccentricities (εx and εy), the Reynolds number (Re), the Grashof number (Gr), and the Richardson number (Ri). The flow and heat transfer behavior in the cavity for a range of Richardson number (0.01–100) at a fixed Reynolds number (100) and Prandtl number (0.71) is examined comprehensively. The variations of the average and local Nusselt number at the blockage surface at various Richardson numbers for different blockage sizes and placement eccentricities are presented. From the analysis of the mixed convection process, it is found that for any size of the blockage placed anywhere in the cavity, the average Nusselt number does not change significantly with increasing Richardson number until it approaches the value of the order of 1 beyond which the average Nusselt number increases rapidly with the Richardson number. For the central placement of the blockage at any fixed Richardson number, the average Nusselt number decreases with increasing blockage ratio and reaches a minimum at around a blockage ratio of slightly larger than 1/2. For further increase of the blockage ratio, the average Nusselt number increases again and becomes independent of the Richardson number. The most preferable heat transfer (based on the average Nusselt number) is obtained when the blockage is placed around the top left and the bottom right corners of the cavity.


2020 ◽  
Vol 45 (4) ◽  
pp. 373-383
Author(s):  
Nepal Chandra Roy ◽  
Sadia Siddiqa

AbstractA mathematical model for mixed convection flow of a nanofluid along a vertical wavy surface has been studied. Numerical results reveal the effects of the volume fraction of nanoparticles, the axial distribution, the Richardson number, and the amplitude/wavelength ratio on the heat transfer of Al2O3-water nanofluid. By increasing the volume fraction of nanoparticles, the local Nusselt number and the thermal boundary layer increases significantly. In case of \mathrm{Ri}=1.0, the inclusion of 2 % and 5 % nanoparticles in the pure fluid augments the local Nusselt number, measured at the axial position 6.0, by 6.6 % and 16.3 % for a flat plate and by 5.9 % and 14.5 %, and 5.4 % and 13.3 % for the wavy surfaces with an amplitude/wavelength ratio of 0.1 and 0.2, respectively. However, when the Richardson number is increased, the local Nusselt number is found to increase but the thermal boundary layer decreases. For small values of the amplitude/wavelength ratio, the two harmonics pattern of the energy field cannot be detected by the local Nusselt number curve, however the isotherms clearly demonstrate this characteristic. The pressure leads to the first harmonic, and the buoyancy, diffusion, and inertia forces produce the second harmonic.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
C. Neil Jordan ◽  
Lesley M. Wright

An alternative to ribs for internal heat transfer enhancement of gas turbine airfoils is dimpled depressions. Relative to ribs, dimples incur a reduced pressure drop, which can increase the overall thermal performance of the channel. This experimental investigation measures detailed Nusselt number ratio distributions obtained from an array of V-shaped dimples (δ/D = 0.30). Although the V-shaped dimple array is derived from a traditional hemispherical dimple array, the V-shaped dimples are arranged in an in-line pattern. The resulting spacing of the V-shaped dimples is 3.2D in both the streamwise and spanwise directions. A single wide wall of a rectangular channel (AR = 3:1) is lined with V-shaped dimples. The channel Reynolds number ranges from 10,000–40,000. Detailed Nusselt number ratios are obtained using both a transient liquid crystal technique and a newly developed transient temperature sensitive paint (TSP) technique. Therefore, the TSP technique is not only validated against a baseline geometry (smooth channel), but it is also validated against a more established technique. Measurements indicate that the proposed V-shaped dimple design is a promising alternative to traditional ribs or hemispherical dimples. At lower Reynolds numbers, the V-shaped dimples display heat transfer and friction behavior similar to traditional dimples. However, as the Reynolds number increases to 30,000 and 40,000, secondary flows developed in the V-shaped concavities further enhance the heat transfer from the dimpled surface (similar to angled and V-shaped rib induced secondary flows). This additional enhancement is obtained with only a marginal increase in the pressure drop. Therefore, as the Reynolds number within the channel increases, the thermal performance also increases. While this trend has been confirmed with both the transient TSP and liquid crystal techniques, TSP is shown to have limited capabilities when acquiring highly resolved detailed heat transfer coefficient distributions.


2021 ◽  
Vol 4 (8(112)) ◽  
pp. 16-22
Author(s):  
Mahmoud A. Mashkour

The heat convection phenomenon has been investigated numerically (mathematically) for a channel located horizontally and partially heated at a uniform heat flux with forced and free heat convection. The investigated horizontal channel with a fluid inlet and the enclosure was exposed to the heat source from the bottom while the channel upper side was kept with a constant temperature equal to fluid outlet temperature. Transient, laminar, incompressible and mixed convective flow is assumed within the channel. Therefore, the flow field is estimated using Navier Stokes equations, which involves the Boussinesq approximation. While the temperature field is calculated using the standard energy model, where, Re, Pr, Ri are Reynolds number, Prandtl number, and Richardson number, respectively. Reynolds number (Re) was changed during the test from 1 to 50 (1, 10, 25, and 50) for each case study, Richardson (Ri) number was changed during the test from 1 to 25 (1, 5, 10, 15, 20, and, 25). The average Nusselt number (Nuav) increases exponentially with the Reynold number for each Richardson number and the local Nusselt number (NuI) rises in the heating point. Then gradually stabilized until reaching the endpoint of the channel while the local Nusselt number increases with a decrease in the Reynolds number over there. In addition, the streamlines and isotherms patterns in case of the very low value of the Reynolds number indicate very low convective heat transfer with all values of Richardson number. Furthermore, near the heat source, the fluid flow rate rise increases the convection heat transfer that clarified the Nusselt number behavior with Reynolds number indicating that maximum Nu No. are 6, 12, 27 and 31 for Re No. 1, 10, 25 and 50, respectively


2019 ◽  
Vol 30 (5) ◽  
pp. 2781-2807
Author(s):  
Davood Toghraie ◽  
Ehsan Shirani

Purpose The purpose of this paper is to investigate the mixed convection of a two-phase water–aluminum oxide nanofluid in a cavity under a uniform magnetic field. Design/methodology/approach The upper wall of the cavity is cold and the lower wall is warm. The effects of different values of Richardson number, Hartmann number, cavitation length and solid nanoparticles concentration on the flow and temperature field and heat transfer rate were evaluated. In this paper, the heat flux was assumed to be constant of 10 (W/m2) and the Reynolds number was assumed to be constant of 300 and the Hartmann number and the volume fraction of solid nanoparticles varied from 0 to 60 and 0 to 0.06, respectively. The Richardson number was considered to be 0.1, 1 and 5. Aspect ratios were 1, 1.5 and 2. Findings Comparison of the results of this paper with the results of the numerical and experimental studies of other researchers showed a good correlation. The results were presented in the form of velocity and temperature profiles, stream and isotherm lines and Nusselt numbers. The results showed that by increasing the Hartmann number, the heat transfer rate decreases. An increase from 0 to 20 in Hartmann number results in a 20 per cent decrease in Nusselt numbers, and by increasing the Hartmann number from 20 to 40, a 16 per cent decrease is observed in Nusselt number. Accordingly, it is inferred that by increasing the Hartmann number, the reduction in the Nusselt number is decreased. As the Richardson number increased, the heat transfer rate and, consequently, the Nusselt number increased. Therefore, an increase in the Richardson number results in an increase of the Nusselt number, that is, an increase in Richardson number from 0.1 to 1 and from 1 to 5 results in 37 and 47 per cent increase in Nusselt number, respectively. Originality/value Even though there have been numerous investigations conducted on convection in cavities under various configurations and boundary conditions, relatively few studies are conducted for the case of nanofluid mixed convection in square lid-driven cavity under the effect of magnetic field using two-phase model.


2020 ◽  
Vol 142 (8) ◽  
Author(s):  
Muneer A. Ismael ◽  
Ahmed Kadhim Hussein ◽  
Fateh Mebarek-Oudina ◽  
Lioua Kolsi

Abstract The mixed convection in an open trapezoidal lid-driven cavity connected with a channel is investigated in the present paper. Four different cases were considered depending on the movement of the cavity sidewalls. For case I, the left sidewall moves downward; for case II, the left sidewall moves downward and the right one moves upward; while for case III, only the right sidewall moves upward. A comparative case (case 0) is accounted when both sidewalls are assumed stationary. The base of the cavity is subjected to a localized heat source of constant temperature Th. The effects of Richardson number Ri and Reynolds number ratio Rer on the flow and thermal fields have been investigated. The results indicated that for cases I and II, the average Nusselt number increases with the increase of the Richardson number and Reynolds number ratio. Moreover, it was found that the maximum average Nusselt number occurs with case I. When the lid-driven speed is three times that of the inlet airflow velocity, the augmentations of the average Nusselt number compared with stationary walls are 163%, 158%, and 96% for cases I, II, and III, respectively.


2019 ◽  
Vol 141 (7) ◽  
Author(s):  
Ankit Tiwari ◽  
Savas Yavuzkurt

The goal of this study is to evaluate the computational fluid dynamic (CFD) predictions of friction factor and Nusselt number from six different low Reynolds number k–ε (LRKE) models namely Chang–Hsieh–Chen (CHC), Launder–Sharma (LS), Abid, Lam–Bremhorst (LB), Yang–Shih (YS), and Abe–Kondoh–Nagano (AKN) for various heat transfer enhancement applications. Standard and realizable k–ε (RKE) models with enhanced wall treatment (EWT) were also studied. CFD predictions of Nusselt number, Stanton number, and friction factor were compared with experimental data from literature. Various parameters such as effect of type of mesh element and grid resolution were also studied. It is recommended that a model, which predicts reasonably accurate values for both friction factor and Nusselt number, should be chosen over disparate models, which may predict either of these quantities more accurately. This is based on the performance evaluation criterion developed by Webb and Kim (2006, Principles of Enhanced Heat Transfer, 2nd ed., Taylor and Francis Group, pp. 1–72) for heat transfer enhancement. It was found that all LRKE models failed to predict friction factor and Nusselt number accurately (within 30%) for transverse rectangular ribs, whereas standard and RKE with EWT predicted friction factor and Nusselt number within 25%. Conversely, for transverse grooves, AKN, AKN/CHC, and LS (with modified constants) models accurately predicted (within 30%) both friction factor and Nusselt number for rectangular, circular, and trapezoidal grooves, respectively. In these cases, standard and RKE predictions were inaccurate and inconsistent. For longitudinal fins, Standard/RKE model, AKN, LS and Abid LRKE models gave the friction factor and Nusselt number predictions within 25%, with the AKN model being the most accurate.


Author(s):  
Sampath Kumar Chinige ◽  
Arvind Pattamatta

An experimental study using Liquid crystal thermography technique is conducted to study the convective heat transfer enhancement in jet impingement cooling in the presence of porous media. Aluminium porous sample of 10 PPI with permeability 2.48e−7 and porosity 0.95 is used in the present study. Results are presented for two different Reynolds number 400 and 700 with four different configurations of jet impingement (1) without porous foams (2) over porous heat sink (3) with porous obstacle case (4) through porous passage. Jet impingement with porous heat sink showed a deterioration in average Nusselt number by 10.5% and 18.1% for Reynolds number of 400 and 700 respectively when compared with jet impingement without porous heat sink configuration. The results show that for Reynolds number 400, jet impingement through porous passage augments average Nusselt number by 30.73% whereas obstacle configuration enhances the heat transfer by 25.6% over jet impingement without porous medium. Similarly for Reynolds number 700, the porous passage configuration shows average Nusselt number enhancement by 71.09% and porous obstacle by 33.4 % over jet impingement in the absence of porous media respectively.


Author(s):  
H. Mohammed ◽  
T. Yusaf

This paper aims to investigate the effect of the flow pattern on the mixed convection heat transfer. A 28 thermocouples wire were installed along a 900mm copper tube to measure the temperature distribution. Three insulation layers of fiber glass, asbestos and gypsum were used to minimize to heat lost to the surrounding. A forced convection at the entrance region of a fully developed opposing laminar air flow was investigated to evaluate the flow direction effect on the Nusselt number. The investigation covered a wide range of Reynolds number from 410 to 1600 and heat flux varied from 63W/m2 to 1260W/m2, with different angles of tube inclination of 30°, 45°, 60°, and 90°. It was found that the surface temperature variation along the tube for opposed flow higher than the assisted flow but lower than the horizontal orientation. The Reynolds number has a significant effect on Nusselt number in opposed flow while the effect of Reynolds number was found to be small in the case of assisted flow. The Nusselt number values were lower for opposed flow than the assisted flow. The temperature profiles results have revealed that the secondary flows created by natural convection have a significant effect on the heat transfer process. The obtained average Nusselt number values were correlated by dimensionless groups as Log Nu against Log Ra/Re.


Author(s):  
S.A.M. Said ◽  
M.A. Habib ◽  
M.O. Iqbal

A numerical investigation aimed at understanding the flow and heat transfer characteristics of pulsating turbulent flow in an abrupt pipe expansion was carried out. The flow patterns are classified by four parameters; the Reynolds number, the Prandtl number, the abrupt expansion ratio and the pulsation frequency. The influence of these parameters on the flow was studied in the range 104<Re<5×104, 0.7<Pr<7.0, 0.2<d/D<0.6 and 5<f<35. It was found that the influence of pulsation on the mean time‐averaged Nusselt number is insignificant (around 10 per cent increase) for fluids having a Prandtl number less than unity. This effect is appreciable (around 30 per cent increase) for fluids having Prandtl number greater than unity. For all pulsation frequencies, the variation in the mean time‐averaged Nusselt number, maximum Nusselt number and its location with Reynolds number and diameter ratio exhibit similar characteristics to steady flows.


Sign in / Sign up

Export Citation Format

Share Document