scholarly journals Two-year Water Degradation of Self-etching Adhesives Bonded to Bur Ground Enamel

2009 ◽  
Vol 34 (6) ◽  
pp. 732-740 ◽  
Author(s):  
A. I. Abdalla ◽  
A. J. Feilzer

Clinical Relevance All the adhesives tested showed no difference in bond strength after 24-hours of water storage. After two years of water storage, the bonds produced by some self-etch adhesives were significantly reduced.


10.2341/07-42 ◽  
2008 ◽  
Vol 33 (1) ◽  
pp. 79-88 ◽  
Author(s):  
A. D. Loguercio ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
R. T. Patzlaff ◽  
...  

Clinical Relevance The effect of surface preparation was adhesive-dependent. Improvements in resin-enamel bond strength after enamel preparation were observed only for AdheSE and Optibond Solo plus Self-Etch Primer. Among the self-etch systems, mild, self-etch Clearfil SE Bond showed the highest bond strength values. No degradation of resin-enamel bonds was observed after 12 months of water storage, regardless of the adhesive tested.



10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.



2010 ◽  
Vol 35 (4) ◽  
pp. 428-435 ◽  
Author(s):  
A. Reis ◽  
C. Zander-Grande ◽  
S. Kossatz ◽  
R. Stanislawczuk ◽  
A. Manso ◽  
...  

Clinical Relevance All Bond 3 and All Bond Self-Etch are versatile systems, capable of being used either in the full or simplified version. Both showed adequate microtensile bond strength results in enamel and dentin after 24 hours of water storage.



10.2341/05-53 ◽  
2006 ◽  
Vol 31 (4) ◽  
pp. 431-441 ◽  
Author(s):  
A. D. Loguercio ◽  
A. Reis ◽  
G. Bortoli ◽  
R. Patzlaft ◽  
S. Kenshima ◽  
...  

Clinical Relevance Etch & rinse systems showed better initial interfacial adaptation than self-etch systems. The differences disappeared after 6-months water storage. The thicker the hybrid layer formed by self-etching adhesives, the lower the immediate gap formation.



2013 ◽  
Vol 24 (4) ◽  
pp. 335-339 ◽  
Author(s):  
Cesar Pomacondor-Hernandez ◽  
Alberto Nogueira de Gama Antunes ◽  
Vinicius di Hipolito ◽  
Mario Fernando de Goes

The purpose of this study was to evaluate the effect of replacing a component of the self-etch adhesive Adper Scotchbond SE (liquid A + liquid B) by 2% chlorhexidine (CHX) on bond strength to dentin after 1 day, 3 months or 6 months of water storage. Eight human teeth were sectioned to expose a flat dentin surface and were then randomly assigned to 2 groups. In the control group, the dentin surfaces were treated with the adhesive according to the manufacturer's instructions. In the experimental group, liquid A was replaced by 2% CHX. Next, a 6-mm-high resin composite block was incrementally built on the bonded surfaces. The restored teeth were then sectioned to produce stick-shaped specimens (cross-sectional area - 0.8 mm2). The microtensile bond strength (µTBS) was recorded, and the failure modes were assessed. Data were analyzed by two-way repeated measures ANOVA (α=0.05). Four additional teeth were processed in order to conduct a micromorphological analysis of the resin-dentin interface. The µTBS values did not significantly decrease after water storage in either the control or the experimental group, whose values did not differ significantly irrespective of storage time. The morphological aspect of the bonding interface appears not to have been affected by CHX. A higher incidence of cohesive failures within the adhesive and mixed failures (cohesive within adhesive and resin composite) was observed for both groups. It may be concluded that dentin pre-treatment with 2% CHX did not influence significantly the bonding performance of the evaluated adhesive.



2009 ◽  
Vol 34 (6) ◽  
pp. 716-724 ◽  
Author(s):  
S. Wei ◽  
Y. Shimada ◽  
A. Sadr ◽  
J. Tagami

Clinical Relevance Double-application enhanced the hardness of bonding layer and resin-dentin interface for all the adhesives used; however, it only improved the bond strength to dentin for some of the single-step self-etch adhesives.



2006 ◽  
Vol 31 (1) ◽  
pp. 18-24 ◽  
Author(s):  
Y. Asaka ◽  
M. Miyazaki ◽  
T. Takamizawa ◽  
K. Tsubota ◽  
B. K. Moore

Clinical Relevance The delay in placement of composite over single-application self-etching adhesive systems was a crucial factor influencing dentin bond strength compared to a composite placed immediately after the polymerization of adhesives.



2010 ◽  
Vol 35 (1) ◽  
pp. 77-83 ◽  
Author(s):  
H. Tsuchiya ◽  
K. Tsubota ◽  
M. Iwasa ◽  
S. Ando ◽  
M. Miyazaki ◽  
...  

Clinical Relevance Proper application duration of single-step self-etch adhesive plays an important role in obtaining optimal enamel bond strength.



2018 ◽  
Vol 43 (4) ◽  
pp. 391-397 ◽  
Author(s):  
RC Ferreira-Filho ◽  
C Ely ◽  
RC Amaral ◽  
JA Rodrigues ◽  
J-F Roulet ◽  
...  

SUMMARY Objective: The purpose of this study was to investigate the immediate and three-month water storage behavior of adhesives when used for immediate dentin sealing (IDS). Methods and Materials: Four adhesive systems were used to perform IDS: a one-step self-etch (Xeno V), a two-step self-etch (Clearfil SE Bond), a two-step etch-and-rinse (XP Bond), and a three-step etch-and-rinse (Optibond FL). For the control group, IDS was not performed. The self-adhesive resin cement RelyX Unicem was used for the luting procedures. After seven days of water storage, specimens (n=6) were sectioned into beams (n=5) with an approximately 1-mm2 cross-sectional area. Half of the specimens were tested in tension after seven days of water storage at 37°C, while the other half was stored for three months prior to testing in tension using a universal testing machine (1 mm/min). The failure pattern was determined using a stereomicroscope and scanning electron microscopy. Microtensile bond strength (μTBS) data were statistically analyzed by two-way analysis of variance and Tukey post hoc test (α=0.05). Results: After seven days, the control group presented the lowest μTBS but did not differ from XP Bond and Clearfil SE Bond. After three months, there was no μTBS difference between the IDS groups and the control. Conclusions: After seven days of water storage, the groups with IDS presented higher μTBS values than the control group, although XP Bond and Clearfil SE Bond did not present significant differences. However, after three months of storage in water, IDS groups did not differ significantly from control group, which did not receive IDS.



2010 ◽  
Vol 35 (2) ◽  
pp. 211-219 ◽  
Author(s):  
R. C. Amaral ◽  
R. Stanislawczuk ◽  
C. Zander-Grande ◽  
D. Gagler ◽  
A. Reis ◽  
...  

Clinical Relevance Vigorous application on the dentin surface is an excellent tool capable of improving the immediate performance of simplified self-etch adhesive systems.



Sign in / Sign up

Export Citation Format

Share Document