scholarly journals Reparability of Aged Silorane With Methacrylate-Based Resin Composite: Micro-Shear Bond Strength and Scanning Electron Microscopy Evaluation

2012 ◽  
Vol 37 (1) ◽  
pp. 28-36 ◽  
Author(s):  
L Giachetti ◽  
D Scaminaci Russo ◽  
M Baldini ◽  
C Goracci ◽  
M Ferrari

Clinical Relevance Aged silorane composite restorations can be repaired with a methacrylate-based resin composite by using a phosphate-methacrylate–based adhesive as the intermediate layer.

Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3578
Author(s):  
Mihaela Pastrav ◽  
Andrea Maria Chisnoiu ◽  
Ovidiu Pastrav ◽  
Codruta Sarosi ◽  
Doina Pordan ◽  
...  

Orthodontic adhesives have similar properties in terms of fluoride release, roughness, shear bond strength or cement debris for specific clinical conditions. Three commercial consecrated orthodontic adhesives (Opal Seal®, Blugloo®, Light Bond®) were compared with an experimental orthodontic material (C1). Brackets were bonded to enamel using a self-etch technique followed by adhesive application and then de-bonded 60 days later. Share bond strength evaluation, scanning electron microscopy, atomic force microscopy and fluoride release analysis were performed. The highest amount of daily and cumulative fluoride release was obtained for the experimental material, while the lowest value was observed for Opal Seal®. The materials evaluated in the current study presented adequate shear bond strength, with the experimental material having a mean value higher than Opal Seal and Blugloo. The atomic force microscopy measurements indicated that the smoothest initial sample is Opal Seal® followed by Light Bond®. Scanning electron microscopy evaluation indicated different aspects of cement debris on the enamel and/or bracket surface, according to the type of adhesive. The experimental material C1 presented adequate properties in terms of shear bond strength, fluoride release, roughness and enamel characteristics after de-bonding, compared to the commercial materials. Under these circumstances, it can be considered for clinical testing.


2021 ◽  
Vol 11 (2) ◽  
pp. 54-61
Author(s):  
Fatih Demirci ◽  
Samet Tekin

Aim: In this in vitro study, the effect of two adhesive systems applied to surfaces of different polyether-ether-ketone (PEEK) composites on the shear bond strength (SBS) of a composite resin was compared. Methodology: Eighty PEEK specimens were divided into four groups (n=20): Unfilled PEEK (UF), carbon-fiber-reinforced PEEK (CFR), glass-fiber-reinforced PEEK (GFR), and ceramic-reinforced PEEK (CR). Each group was further divided into two subgroups (n=10): Visio.link (VL) and Single Bond Universal (SB). The specimens with 8-mm diameter and 5-mm thickness were prepared. SBS was examined using a universal testing machine. Results were statistically analyzed by multivariate analysis of variance and Tukey’s post-hoc test. Failure modes were analyzed using a stereomicroscope at 20× magnification. Surface properties were examined by scanning electron microscopy. The surface properties of the specimens were examined by scanning electron microscopy (SEM).  Results: Effect of different PEEK and adhesive systems on SBS was found to be statistically significant (p<0.05). SBS values for CFR-VL and UF-VL groups were statistically more significant than those for CFR-SB and UF-SB groups (p=0.001). SBS values for the GFR-VL group were statistically more significant than that for the UF-VL group (p=0.001). SBS values for the CF-SB group were statistically more significant than those for CFR-SB and CFR-SB groups (p=0.001). Failure modes were examined using a stereomicroscope at 20× magnification, and adhesive and mixed failure modes were observed. Conclusion: PEEK composites with different contents and properties can be used in fixed prosthetic restorations. However, additional experimental and clinical studies are required to investigate different PEEK frameworks and composite veneers.   How to cite this article: Demirci F, Tekin S. Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength. Int Dent Res 2021;11(2):54-61. https://doi.org/10.5577/intdentres.2021.vol11.no2.1   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2020 ◽  
Vol 23 (4) ◽  
pp. 12p
Author(s):  
Pinar Cevik ◽  
Arzu Zeynep Yildirim ◽  
Zafer Artvin ◽  
Mutlu Özcan

Objective: The aim of this study was to evaluate and compare the microtensile bond strengths of four current adhesive materials that contain different monomers at deep and superficial dentin. Material and Methods: Forty non-carious human third molars (n = 5) were used in the study. Specimens were divided into two main groups according to dentin thickness as superficial and deep dentin. Groups were further divided into four subgroups in terms of the adhesive systems used: Nova Compo B Plus (NCBP), Nova Compo B (NCB), Futurabond M (FB) and Clearfil S3 Bond Plus (CS3). All specimens were bonded to resin composite and stored in 37 °C water for 9-months. Teeth were sectioned into 3 x 3 mm x 1mm thick beams. Microtensile bond strength test was carried out by using a universal testing device (1 mm/min). After fracture, failure types were observed using an optical microscope and the fractured dentin surfaces were observed by a scanning electron microscopy (SEM). One-way ANOVA and Tukey tests were used to compare the adhesive system in each dentin group. An unpaired T-test was used to compare the dentin thickness in each adhesive material. Results: As compared to deep dentin, superficial dentin showed higher µTBS values in groups NCBP, FB and CS, as opposed to group NCB. Only NCB revealed higher bond strength at deep dentin layers when compared to superficial dentin. In the superficial dentin group, NCBP showed the highest bond strength value, while NCB showed the lowest bond strength. In the deep dentin group, while NCB showed the highest bond strength value, NCBP revealed the lowest bond strength value after 9-months storage. While 4-META and 10-MDP monomer combination (NCBP) resulted in the highest bond strength value among the adhesive systems in the superficial dentin group, the monomer combination (NCB) resulted in the highest bond strength in deep dentin group. Conclusions: Microtensile bond strength performance are affected by both the type of monomer in the adhesive combination and the depth of the dentin. KEYWORDS Adhesive system; dentin thickness; hydrophobic monomer; microtensile bond strength; scanning electron microscopy.


2013 ◽  
Vol 18 (3) ◽  
pp. 124-129 ◽  
Author(s):  
Murilo Gaby Neves ◽  
Gustavo Antônio Martins Brandão ◽  
Haroldo Amorim de Almeida ◽  
Ana Maria Martins Brandão ◽  
Dário Ribeiro de Azevedo

OBJECTIVE: To evaluate, in vitro, the shear bond strength of self-curing (ConciseTM - 3M and Alpha Plast - DFL) and light-curing composites (TransbondTM XT - 3M and Natural Ortho - DFL) used in orthodontics bonding, associated to Morelli metal brackets, with further analysis of adhesive remnant index (ARI) and enamel condition in scanning electron microscopy (SEM). METHODS: Forty human premolars, just extracted and stored in physiologic solution 0.9 % were used. Randomly, these samples were divided in four groups: G1 group, the brackets were bonded with ConciseTM - 3M composite; in G2 group, Alpha Plast - DFL composite was used; in G3 group, TransbondTM XT - 3M was used; in G4 group, Natural Ortho - DFL composite was used. These groups were submitted to shear strength tests in universal testing machine, at 0.5 mm per minute speed. RESULTS: Statistical difference between G3 and G4 groups was recorded, as G4 showing higher strength resistance than G3. In the other hand, there were no statistical differences between G1, G2 and G3 and G1, G2 and G4 groups. ARI analysis showed that there was no statistical difference between the groups, and low scores were recorded among then. The scanning electron microscopy (SEM) analysis revealed the debonding spots and the enamel surface integrity. CONCLUSIONS: Shear bond strength was satisfactory and similar between the composites, however Natural Ortho - DFL revealed best comparing to TransbondTM XT - 3M.


Sign in / Sign up

Export Citation Format

Share Document