scholarly journals In vitro analysis of shear bond strength and adhesive remnant index comparing light curing and self-curing composites

2013 ◽  
Vol 18 (3) ◽  
pp. 124-129 ◽  
Author(s):  
Murilo Gaby Neves ◽  
Gustavo Antônio Martins Brandão ◽  
Haroldo Amorim de Almeida ◽  
Ana Maria Martins Brandão ◽  
Dário Ribeiro de Azevedo

OBJECTIVE: To evaluate, in vitro, the shear bond strength of self-curing (ConciseTM - 3M and Alpha Plast - DFL) and light-curing composites (TransbondTM XT - 3M and Natural Ortho - DFL) used in orthodontics bonding, associated to Morelli metal brackets, with further analysis of adhesive remnant index (ARI) and enamel condition in scanning electron microscopy (SEM). METHODS: Forty human premolars, just extracted and stored in physiologic solution 0.9 % were used. Randomly, these samples were divided in four groups: G1 group, the brackets were bonded with ConciseTM - 3M composite; in G2 group, Alpha Plast - DFL composite was used; in G3 group, TransbondTM XT - 3M was used; in G4 group, Natural Ortho - DFL composite was used. These groups were submitted to shear strength tests in universal testing machine, at 0.5 mm per minute speed. RESULTS: Statistical difference between G3 and G4 groups was recorded, as G4 showing higher strength resistance than G3. In the other hand, there were no statistical differences between G1, G2 and G3 and G1, G2 and G4 groups. ARI analysis showed that there was no statistical difference between the groups, and low scores were recorded among then. The scanning electron microscopy (SEM) analysis revealed the debonding spots and the enamel surface integrity. CONCLUSIONS: Shear bond strength was satisfactory and similar between the composites, however Natural Ortho - DFL revealed best comparing to TransbondTM XT - 3M.

2021 ◽  
Vol 11 (2) ◽  
pp. 54-61
Author(s):  
Fatih Demirci ◽  
Samet Tekin

Aim: In this in vitro study, the effect of two adhesive systems applied to surfaces of different polyether-ether-ketone (PEEK) composites on the shear bond strength (SBS) of a composite resin was compared. Methodology: Eighty PEEK specimens were divided into four groups (n=20): Unfilled PEEK (UF), carbon-fiber-reinforced PEEK (CFR), glass-fiber-reinforced PEEK (GFR), and ceramic-reinforced PEEK (CR). Each group was further divided into two subgroups (n=10): Visio.link (VL) and Single Bond Universal (SB). The specimens with 8-mm diameter and 5-mm thickness were prepared. SBS was examined using a universal testing machine. Results were statistically analyzed by multivariate analysis of variance and Tukey’s post-hoc test. Failure modes were analyzed using a stereomicroscope at 20× magnification. Surface properties were examined by scanning electron microscopy. The surface properties of the specimens were examined by scanning electron microscopy (SEM).  Results: Effect of different PEEK and adhesive systems on SBS was found to be statistically significant (p<0.05). SBS values for CFR-VL and UF-VL groups were statistically more significant than those for CFR-SB and UF-SB groups (p=0.001). SBS values for the GFR-VL group were statistically more significant than that for the UF-VL group (p=0.001). SBS values for the CF-SB group were statistically more significant than those for CFR-SB and CFR-SB groups (p=0.001). Failure modes were examined using a stereomicroscope at 20× magnification, and adhesive and mixed failure modes were observed. Conclusion: PEEK composites with different contents and properties can be used in fixed prosthetic restorations. However, additional experimental and clinical studies are required to investigate different PEEK frameworks and composite veneers.   How to cite this article: Demirci F, Tekin S. Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength. Int Dent Res 2021;11(2):54-61. https://doi.org/10.5577/intdentres.2021.vol11.no2.1   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2012 ◽  
Vol 37 (1) ◽  
pp. 28-36 ◽  
Author(s):  
L Giachetti ◽  
D Scaminaci Russo ◽  
M Baldini ◽  
C Goracci ◽  
M Ferrari

Clinical Relevance Aged silorane composite restorations can be repaired with a methacrylate-based resin composite by using a phosphate-methacrylate–based adhesive as the intermediate layer.


2021 ◽  
Vol 11 (17) ◽  
pp. 8251
Author(s):  
Yuriko Tezuka ◽  
Yasuhiro Namura ◽  
Akihisa Utsu ◽  
Kiyotaka Wake ◽  
Yasuki Uchida ◽  
...  

This study was performed to investigate the influence of pre-etching area and functional monomers in orthodontic adhesive pastes on enamel bond strength. Bovine enamel was partially pre-etched with phosphoric acid for 30 s over areas with a diameter of 1.0, 2.0 or 3.0 mm, and metal brackets were then bonded with or without functional monomers in the orthodontic adhesive paste. For the baseline groups, the whole adherent area was pre-etched. The shear bond strength (SBS) and adhesive remnant index (ARI) were determined. The adhesive paste/enamel interfaces were observed by scanning electron microscopy (SEM). Although the adhesive paste with functional monomers showed higher SBS than the functional monomer-free adhesive paste in all groups, there were no significant differences in SBS between them regardless of the pre-etched area. The SBS increased with increasing pre-etched area in both orthodontic adhesive pastes. In SEM images of adhesive paste/enamel interfaces, although adhesive with functional monomers showed excellent adaptation, the functional monomer-free adhesive paste showed gap formation at the interface. These findings suggested that the pre-etching area greatly influenced bond strength, regardless of the presence or absence of the functional monomer in the orthodontic adhesive paste.


2011 ◽  
Vol 82 (1) ◽  
pp. 158-164 ◽  
Author(s):  
Maria Francesca Sfondrini ◽  
Esmeralda Xheka ◽  
Andrea Scribante ◽  
Paola Gandini ◽  
Giuseppe Sfondrini

Abstract Objective: To test the null hypothesis that there is no significant difference in the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of new vs reconditioned self-ligating brackets. Materials and Methods: One hundred and twenty permanent extracted bovine teeth were embedded in resin blocks. Three different new and reconditioned self-ligating orthodontic brackets (Smart Clip [3M Unitek]; Quick [Forestadent]; and Damon3MX [Ormco]) were tested. Scanning electron microphotographs of the different new (groups 1, 3, and 5) and reconditioned (groups 2, 4, and 6) bracket bases were taken before starting the experiments. Brackets were then bonded to the teeth using an orthodontic adhesive and were then tested in shear mode using an Instron Universal Testing Machine. ARI scores were then recorded. Statistical analysis was performed to determine significant differences in SBS and ARI Scores. Results: Smart Clip and Damon3MX reconditioned brackets showed significantly lower SBS than did new ones. On the contrary, Quick reconditioned brackets showed significantly higher SBS than did new ones. No significant differences in ARI scores were found after the reconditioning process for the three different brackets tested. Conclusion: The in-office reconditioning procedure alters the SBS of self-ligating brackets, although SBS values still remain clinically acceptable.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3578
Author(s):  
Mihaela Pastrav ◽  
Andrea Maria Chisnoiu ◽  
Ovidiu Pastrav ◽  
Codruta Sarosi ◽  
Doina Pordan ◽  
...  

Orthodontic adhesives have similar properties in terms of fluoride release, roughness, shear bond strength or cement debris for specific clinical conditions. Three commercial consecrated orthodontic adhesives (Opal Seal®, Blugloo®, Light Bond®) were compared with an experimental orthodontic material (C1). Brackets were bonded to enamel using a self-etch technique followed by adhesive application and then de-bonded 60 days later. Share bond strength evaluation, scanning electron microscopy, atomic force microscopy and fluoride release analysis were performed. The highest amount of daily and cumulative fluoride release was obtained for the experimental material, while the lowest value was observed for Opal Seal®. The materials evaluated in the current study presented adequate shear bond strength, with the experimental material having a mean value higher than Opal Seal and Blugloo. The atomic force microscopy measurements indicated that the smoothest initial sample is Opal Seal® followed by Light Bond®. Scanning electron microscopy evaluation indicated different aspects of cement debris on the enamel and/or bracket surface, according to the type of adhesive. The experimental material C1 presented adequate properties in terms of shear bond strength, fluoride release, roughness and enamel characteristics after de-bonding, compared to the commercial materials. Under these circumstances, it can be considered for clinical testing.


2021 ◽  
Vol 6 (2) ◽  
Author(s):  
Ashish Kamboj

Introduction: The self-etching primer system consists of etchant and primer dispersed in a single unit. The etching and priming are merged as a single step leading to fewer stages in bonding procedure and reduction in the number of steps that also reduces the chance of introduction of error, resulting in saving time for the clinician. It also results in smaller extent of enamel decalcification. Aim: To compare the Shear Bond Strength (SBS) of orthodontic molar tubes bonded with conventional acid etching system and Self-Etch Primers (SEP) and to study the surface appearance of enamel after debonding using surface profilometry and scanning electron microscope. Materials and Methods: The sample of this in-vitro study consisted of sixty caries free, intact extracted mandibular first molar teeth. A molar tube of 0.018” Roth prescription with micro etched base was bonded to each molar with two different bonding agents. All the molar tubes were subsequently tested for evaluation of shear bond strength with a universal testing machine. Surface Profilometry and Scanning Electron Microscope (SEM) was used to evaluate the effect of various light cure adhesives on the enamel morphology. Results: Transbond-XT exhibited the highest bond strength (22.6 MPa) closely followed by Transbond Plus SEP (19.6 MPa). However, Transbond-XT sample also had higher surface roughness and enamel alterations as compared to the Transbond Plus SEP. Conclusion: The adequate bond strength of self-etching primers, less deleterious effects on the enamel and less chair side time due to absence of acid etching makes it a good option for routine use in orthodontics.


2012 ◽  
Vol 23 (6) ◽  
pp. 698-702 ◽  
Author(s):  
Gabriela da Rocha Leódido ◽  
Hianna Oliveira Fernandes ◽  
Mateus Rodrigues Tonetto ◽  
Cristina Dupim Presoto ◽  
Matheus Coêlho Bandéca ◽  
...  

The aim of this in vitro study was to evaluate the shear bond strength of brackets after pre-treatment with different fluoride solutions. This study used 48 freshly extracted sound bovine incisors that were randomly assigned to 4 experimental groups (n=12). CG: (control) without treatment; NF: 4 min application of neutral fluoride; APF: application of 1.23% acidulated phosphate fluoride (APF) for 4 min; and SFV: application of 5% sodium fluoride varnish for 6 h. For each group, after surface treatment, prophylaxis of enamel and bracket bonding with Transbond XT composite resin (3M) were performed following the manufacturer's specifications. The shear bond strength was performed with a universal testing machine 24 h after fixing the brackets. The tooth surfaces were analyzed to verify the adhesive remnant index (ARI). Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). There was statistically significant difference among the groups (p<0.0001). CG and NF groups presented significantly higher bond strength than APF and SFV. There was no significant difference between CG and NF or between APF and SFV (p>0.05). The analysis of ARI scores revealed that most failures occurred at the enamel-resin interface. It may be concluded that the pre-treatment of enamel with 1.23% APF and 5% SFV prior to fixing orthodontic brackets reduces shear bond strength values.


Sign in / Sign up

Export Citation Format

Share Document