scholarly journals Unjuk Kerja Filter Pasif dalam Mereduksi Distorsi Gelombang pada AC/DC Konverter

2020 ◽  
Vol 6 (2) ◽  
pp. 122
Author(s):  
Asnil Asnil

This paper shows the use of passive filters to reduce the distortion of input waves in a single phase uncontrolled rectifier. Simulations are carried out with various passive filter models to get a decrease in the value of Total Harmonic Distortion (THD) and correct the distortion of the uncontrolled single phase rectifier input waveform. The results of the simulation show the shape of the input signal changes in the uncontrolled single-phase rectifier, analyzing the value of power factor improvement and also the THD value.

Author(s):  
R. A. Rani ◽  
Shakir Saat ◽  
Yusmarnita Yusop ◽  
Huzaimah Husin ◽  
F. K. Abdul Rahman ◽  
...  

This paper presents the effect of total harmonic distortion (THD) in power factor correction (PFC) at non-linear load. This study focuses on the relationship between THD and PFC. This is beacuse,the power factor affects THD. This occurs in power system as we have variety of loads, i. e linear load or non-linear load. The variety of loads will influence the sinusoidal waveform, which comes out from harmonic distortion. Thus, based on this study, we can compare the effective method in improving the power factor as it will not disturb the performance of THD. The focus of study is on the single phase load, where the voltage restriction is 240 V.  The analysis will  only focus on the consumer, which depends on the variety of non-linear load. Besides, the parameters for analysis are based on the percentage of THD and the value of power factor. The instrument for measuring the parameter is based on power factor correction device or technique. On the other hand, the method that was used for this study is based on simulation which incorporated the Multisim software. At the end of ths study, we can choose the most effective method that can be used to improve the power factor correction without disturbing the THD.


This paper presents about the comparison between single-phase PFC Cuk converter and bridgeless PFC (BPFC) Cuk converter for low power application. This study attempts to investigate the characteristics of conventional and bridgeless PFC Cuk converter structures with three different output voltages and verified by the simulation results. The BPFC Cuk converter provides a lower Total Harmonic Distortion (THD) of input current than the conventional PFC Cuk converter. However, the conventional PFC Cuk converter has advantage of less maximum current stress at components compared to the BPFC Cuk converter. Conventional and BPFC Cuk converter can achieve an approximately unity power factor (PF).


Author(s):  
Santhi Mary Antony ◽  
Godwin Immanuel

Now day’s the power factor has become a major problem in power system to improve the power quality of the grid, as power factor is affected on the grid due to the nonlinear loads connected to it. Single phase bridgeless AC/DC power factor correction (PFC) topology to improve the power factor as well as the total harmonic distortion (THD) of the utility grid is proposed. By removing the input bridge in conventional PFC converters, the control circuit is simplified; the total harmonics distortion (THD) and power factor (PF) are improved. The PI controller operates in two loops one is the outer control loop which calculates the reference current through LC filter and signal processing. Inner current loop generates PWM switching signals through the PI controller. The output of the proposed PFC topology is verified for prototype using MATLAB circuit simulations. The experimental system is developed, and the simulation results are obtained.