Perceived Duration as a Function of Pitch

1988 ◽  
Vol 67 (1) ◽  
pp. 301-302 ◽  
Author(s):  
Willard L. Brigner

It was demonstrated with 7 observers that the duration of a high frequency tone was perceived to be longer than the duration of a low frequency tone, even though the actual duration of the two tones was equal.

2019 ◽  
Vol 121 (3) ◽  
pp. 1018-1033 ◽  
Author(s):  
C. Lee ◽  
J. J. Guinan ◽  
M. A. Rutherford ◽  
W. A. Kaf ◽  
K. M. Kennedy ◽  
...  

Little is known about the spatial origins of auditory nerve (AN) compound action potentials (CAPs) evoked by moderate to intense sounds. We studied the spatial origins of AN CAPs evoked by 2- to 16-kHz tone bursts at several sound levels by slowly injecting kainic acid solution into the cochlear apex of anesthetized guinea pigs. As the solution flowed from apex to base, it sequentially reduced CAP responses from low- to high-frequency cochlear regions. The times at which CAPs were reduced, combined with the cochlear location traversed by the solution at that time, showed the cochlear origin of the removed CAP component. For low-level tone bursts, the CAP origin along the cochlea was centered at the characteristic frequency (CF). As sound level increased, the CAP center shifted basally for low-frequency tone bursts but apically for high-frequency tone bursts. The apical shift was surprising because it is opposite the shift expected from AN tuning curve and basilar membrane motion asymmetries. For almost all high-level tone bursts, CAP spatial origins extended over 2 octaves along the cochlea. Surprisingly, CAPs evoked by high-level low-frequency (including 2 kHz) tone bursts showed little CAP contribution from CF regions ≤ 2 kHz. Our results can be mostly explained by spectral splatter from the tone-burst rise times, excitation in AN tuning-curve “tails,” and asynchronous AN responses to high-level energy ≤ 2 kHz. This is the first time CAP origins have been identified by a spatially specific technique. Our results show the need for revising the interpretation of the cochlear origins of high-level CAPs-ABR wave 1. NEW & NOTEWORTHY Cochlear compound action potentials (CAPs) and auditory brain stem responses (ABRs) are routinely used in laboratories and clinics. They are typically interpreted as arising from the cochlear region tuned to the stimulus frequency. However, as sound level is increased, the cochlear origins of CAPs from tone bursts of all frequencies become very wide and their centers shift toward the most sensitive cochlear region. The standard interpretation of CAPs and ABRs from moderate to intense stimuli needs revision.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Gary A. Smith ◽  
Sandhya Kistamgari ◽  
Mark Splaingard

Abstract Background Being asleep is an important risk factor for death during a residential fire; however, the high-frequency tone smoke alarms in many homes will not adequately awaken children who are old enough to self-rescue. In a series of previous studies, we identified smoke alarm signals that effectively awaken children 5–12 years old and prompt their escape. Because it is impractical to have separate alarms for children and adults in a household, the purpose of this study is to test whether alarms that are effective in awakening children and prompting their escape are also effective among adults. Methods Using a randomized, non-blinded, repeated measures design, 150 adults 20–49 years old were exposed during stage 4 sleep to four different smoke alarms. Statistical tests included the Kaplan-Meier estimator, generalized Wilcoxon test, and hazard ratios with Wald’s 95% confidence intervals. Results The median age of study subjects was 30.0 years and 67.3% were female. Almost all (n = 149) subjects awakened and performed the escape procedure to all four alarms; one individual did not awaken or escape to the high-frequency tone alarm. The median time-to-awaken was 2.0 s for the high-frequency tone alarm and 1.0 s for the other three alarms. The median time-to-escape for the high-frequency tone alarm was 12.0 s, compared with 10.0 s for the low-frequency tone alarm and 9.0 s each for the female and male voice alarms. All pairwise comparisons between the high-frequency tone alarm and each of the other three alarms were statistically significant for the probability functions for time-to-awaken and time-to-escape. There were no significant differences in these outcome measures between the latter three alarms, except for female voice versus low-frequency tone alarms for time-to-escape. Conclusions All alarms performed well, demonstrating that smoke alarms developed for the unique developmental requirements of sleeping children are also effective among sleeping adults. Compared with a high-frequency tone alarm, use of these alarms may reduce residential fire-related injuries and deaths among children, while also successfully alerting adult members of the household.


2017 ◽  
Vol 114 (5) ◽  
pp. 1201-1206 ◽  
Author(s):  
Magdalena Wojtczak ◽  
Anahita H. Mehta ◽  
Andrew J. Oxenham

In modern Western music, melody is commonly conveyed by pitch changes in the highest-register voice, whereas meter or rhythm is often carried by instruments with lower pitches. An intriguing and recently suggested possibility is that the custom of assigning rhythmic functions to lower-pitch instruments may have emerged because of fundamental properties of the auditory system that result in superior time encoding for low pitches. Here we compare rhythm and synchrony perception between low- and high-frequency tones, using both behavioral and EEG techniques. Both methods were consistent in showing no superiority in time encoding for low over high frequencies. However, listeners were consistently more sensitive to timing differences between two nearly synchronous tones when the high-frequency tone followed the low-frequency tone than vice versa. The results demonstrate no superiority of low frequencies in timing judgments but reveal a robust asymmetry in the perception and neural coding of synchrony that reflects greater tolerance for delays of low- relative to high-frequency sounds than vice versa. We propose that this asymmetry exists to compensate for inherent and variable time delays in cochlear processing, as well as the acoustical properties of sound sources in the natural environment, thereby providing veridical perceptual experiences of simultaneity.


1980 ◽  
Vol 88 (1) ◽  
pp. 93-98 ◽  
Author(s):  
Jeffrey Kroin ◽  
Mordechai Himelfarb ◽  
David Strelioff

A low-frequency tone has been shown to modulate the amplitudes of cochlear microphonic (CM) and whole nerve (N1) responses to a high-frequency tone pip. Whereas the N1 response was always reduced and had two maxima per cycle of the low-frequency signal, the CM response changed from a single- to a double-maxima pattern as the modulator intensity was increased.


2005 ◽  
Vol 16 (02) ◽  
pp. 114-121 ◽  
Author(s):  
Raymond M. Hurley ◽  
Annette Hurley ◽  
Charles I. Berlin

Often ABR threshold testing employs clicks to assess high-frequency hearing, and low-frequency tone bursts to assess low-frequency sensitivity. While a maturation effect has been shown for click stimuli, similar data are lacking for low-frequency toneburst stimuli. Thus, 305 infants ranging in conceptional age (CA) from 33 weeks to 74 weeks were tested. Absolute latencies were measured for wave V at 55, 35, and 25 dB nHL in response to a click and for wave V500 in response to a 500 Hz tone burst. Major wave latency in response to 500 Hz tone bursts decreases with age and do not stabilize by 70 weeks CA. Likewise, waves III and V latencies in response to clicks decrease with age, as has been reported by others, and do not stabilize by 70 weeks CA. Wave I latency produced by clicks did not decrease with age, being mature by 33 weeks CA.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


2016 ◽  
Vol 17 (1) ◽  
pp. 66
Author(s):  
Maria Lina Silva Leite
Keyword(s):  

O objetivo deste estudo foi avaliar os efeitos do Método Pilates sobre a variabilidade da frequência cardíaca, na flexibilidade e nas variáveis antropométricas em indivíduos sedentários. O presente estudo contou com 14 voluntárias do sexo feminino, na faixa etária entre 40 e 55 anos, que realizaram 20 sessões de exercícios do Método Pilates, duas vezes por semana, com duração de 45 minutos cada sessão, dividida em três fases: repouso, exercício e recuperação. As variáveis estudadas foram: os dados antropométricos, flexibilidade avaliada utilizando o teste de sentar-e-alcançar com o Banco de Wells, e intervalos R-R usando um cardiotacômetro. O processamento dos sinais da frequência cardíaca foi efetuado em ambiente MatLab 6.1®, utilizando a TWC. Os dados coletados foram submetidos ao teste de normalidade de Shapiro Wilk e foi utilizado o teste de Wilcoxon e Anova One Way (α = 0,05). Nos resultados, observou-se que não houve diferenças significativas entre os valores antropométricos e de frequência cardíaca, porém houve aumento da flexibilidade com o treinamento. Comparando a primeira e a vigésima sessão com relação aos parâmetros low frequency (LF), high frequency (HF), e relação LF/HF, não houve diferença na fase de repouso e foram constatadas diferenças significativas de LF (p = 0,04) e HF (p = 0,04) na fase de exercício e diferença significativa de LF/HF (p = 0,05) na fase de recuperação. Comparando os parâmetros nos períodos de repouso, exercícios e recuperação durante a primeira sessão e durante a vigésima sessão, não houve diferença significativa nos parâmetros LF, HF e LF/HF. Pode-se concluir que, em relação à flexibilidade, foi observada uma melhora significativa, enquanto a análise da frequência cardíaca caracterizou a intensidade do exercício de 50% da capacidade funcional das voluntárias. Em relação aos parâmetros LF, HF e LF/HF foram observados um aumento da variabilidade da frequência cardíaca, provavelmente produto da atividade do Método Pilates. A Transformada Wavelet (TWC) mostrou-se um Método adequado para as análises da variabilidade da frequência cardíaca.Palavras-chave: frequência cardíaca, Transformada Wavelet, Pilates.


Sign in / Sign up

Export Citation Format

Share Document