scholarly journals HPLC method development for fampridine using Analytical Quality by Design approach

2020 ◽  
Vol 70 (4) ◽  
pp. 465-482
Author(s):  
Béla Kovács ◽  
Francisc Boda ◽  
Ibolya Fülöp ◽  
István Székely-Szentmiklósi ◽  
Éva Katalin Kelemen ◽  
...  

AbstractOffering a systematic and multivariate analysis of the analytical procedure, development and validation of HPLC methods using Quality by Design approach are in the limelight of current research trends. A new, experimental design-aided HPLC method for fampridine was developed and preliminarily validated according to current in-force international guidelines for linearity, accuracy, robustness and precision.The method offers a high throughput sample analysis, with an elution time of 2.9 minutes, and signal detection without excipient interference performed at 262 nm. The method proved to be linear between 1–15 µg mL−1 (R2= 0.9996). The mean recovery was found to be 98.7 ± 1.9 % in the tested range of 2.5–7.5 µg mL−1. Low RSD values (< 1 %) were obtained for both model, intra- and inter-day precision. The limit of detection and limit of quantification were 0.24 and 0.78 µg mL−1, resp. The method proved to be applicable for active substance assay in a pharmaceutical dosage form.

Author(s):  
G.M. Kadam ◽  
A.L. Puyad ◽  
T.M. Kalyankar

A new, economical, simple, accurate, and precise RP-HPLC method was developed for simultaneous assay and content uniformity determination of Sacubitril and Valsartan in bulk and pharmaceutical dosage form. The separation of Sacubitril and Valsartan was achieved within 6 minutes on Phenomenex Luna C18 250 mm x 4.6mm and 5µm Particle Size, column using Acetonitrile: Methanol: Water (30:55:15% v/v/v) as the mobile phase. Detection was carried out at 250 nm wavelength. The retention time of Sacubitril and Valsartan was found to be 2.361 and 3.304 min, respectively. The validation of the developed method was performed in terms of specificity, accuracy, precision, linearity, the limit of detection, the limit of quantification as mentioned in International Conference on Harmonization (ICH) guidelines. The method showed adequate sensitivity concerning linearity, accuracy, and precision over the range 12-36 μg/ml and 13-39 μg/ml for Sacubitril and Valsartan, respectively. The percentage recoveries obtained for Sacubitril and Valsartan were found to be in the range of 98.00 – 102.00 %. The proposed method is suitable for use in quality-control laboratories for quantitative analysis.


Author(s):  
Heena Ar Shaikh ◽  
Vandana Jain

Objective: A simple, accurate, precise, robust reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of telmisartan and nebivolol hydrochloride (HCl) simultaneously in its combined dosage form.Methods: The compounds were well resolved in an isocratic method using the mobile phase composition of acetonitrile: Buffer (potassium dihydrogen orthophosphate pH adjusted 3.1 with orthophosphoric acid) in a ratio of 40:60 v/v at a flow rate of 1.2 ml/min using C18 Shim-pack (150 mm × 4.6 mm, 5 μ) column. The detection was carried out at 280 nm.Results: The retention time of telmisartan and nebivolol HCl was 4.8 min and 6.5 min, respectively. The developed method was validated by evaluating various validation parameters such as linearity, precision, accuracy, robustness, specificity, limit of detection, and limit of quantification according to the international council for harmonization guidelines. The standard calibration curve was obtained in the concentration range of 24–56 μg/ml for telmisartan and 3–7 μg/ml for nebivolol HCl. The overall average % recovery was found out to be 100.35 for telmisartan and 98.84 for nebivolol HCl.Conclusion: Statistical analysis of the data showed that the method is reproducible and selective for the estimation of telmisartan and nebivolol HCl. The proposed method could be used for analysis of telmisartan and nebivolol HCl in their dosage form.


Author(s):  
Khushbu K. Patel ◽  
Arati M. Patel ◽  
C. N. Patel

A new simple, rapid, accurate and precise method for estimation of Bilastine in pharmaceutical dosage form by reverse phase liquid chromatography. The developed method employed mobile phase was Acetonitrile and Ammonium acetate pH 5.0 adjusted with glacial acetic acid with 85:15% v/v and flow rate 1.0ml/min. Method was developed using column C18 Water (150 × 4.6mm, 5µm) and detection wavelength was 215nm. The retention time was found to be 2.519 min. the proposed method was successfully applied to the determination of Bilastine in dosage form. High linearity of developed method was confirmed over concentration range of 25- 150 µg/ml and co-relation co-efficient is 0.996. The percentage RSD for precision and accuracy of the method was found to be less than 2%. The recovery was in the range of 99 – 102% and limit of detection was found to be 0.45µg/ml and limit of quantification was found to be 1.20µg/ml. Bilastine was found to degrade under acid and oxidation conditions. There was no interference of excipient and degradation product in retention time so method was specific. Analytical parameter such as precision, accuracy, limit of detection, limit of quantification and robustness were determined according to international Conference on Harmonization (ICH) guidelines.


2018 ◽  
Vol 2018 ◽  
pp. 1-5
Author(s):  
Boovizhikannan Thangabalan ◽  
Getu Kahsay ◽  
Tadele Eticha

A reversed phase liquid chromatographic method with UV detection at 254 nm for dorzolamide assay in ophthalmic solutions was developed and validated. Chromatographic separation was achieved on a Zorbax SB C18 (250 mm × 4.6 mm, 5 µm) column kept at 30°C with an isocratic mixture of mobile phase (phosphate buffer, pH 2.5, and acetonitrile, 90 : 10 v/v) at a flow rate of 0.8 mL/min. The method was validated for its specificity, linearity, accuracy, precision, limit of detection, limit of quantification, and robustness based on ICH guidelines. The validation studies revealed satisfactory results. The proposed method has been applied for the quantification of dorzolamide in commercial samples. The developed method is fast, simple, specific, accurate, and sensitive, hence can be applied for routine quality control analysis of dorzolamide in pharmaceutical dosage form.


2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 28-34
Author(s):  
Yarasani Prashanthi ◽  
◽  
Faheem Ahmed ◽  
Tentu Nageswara Rao ◽  
Botsa Parvatamma ◽  
...  

A novel approach was used for develop and validate a rapid, accurate, and an isocratic RP-HPLC method with PDA detector for the estimation of ixazomib drug in pharmaceutical dosage forms. Ixazomib was seperated using Agilent 4.6*150 mm, 5μm analytical column, a Waters HPLC system (USA) and a mobile phase consisting of water and acetonitrile in the ratio of 40:60 V/V. The flow rate was set to 0.7 mL/min with 10µL injection volume. The column was maintained at ambient temperature, detector was set at wavelength of 274 nm. The retention time of ixazomib was found to be 2.17 min. The system suitability parameters for ixazomib such as theoretical plates and tailing factor were found to be 4146. Linearity was established for ixazomib such as theoretical plates and telling factor were found to be 4146. Linearilty was established for ixazomib in the range of 50-250 µg/ml concentration levels with correlation coefficients (r2) of 0.999. The intra-and inter-day precision % RSD values were found to be 0.47 and 0.31, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 2.03 and 6.17 µg/mL respectively. The method was validated for all of the above parameters according to the International Conference on Harmonization (ICH) guidelines. This method can be used for estimation and analysis of ixazomib drug in active pharmaceutical ingredients and pharmaceuticals.


2020 ◽  
Vol 10 (1) ◽  
pp. 31-38
Author(s):  
Rahul Suryawanshi ◽  
Siddiqua Shaikh ◽  
Snehal Patil

A new, simple, precise, accurate and reproducible Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for Simultaneous estimation of bulk and pharmaceutical formulations. Separation of Mirabegron was successfully achieve , C18, 250X4.6mm, 5µm or equivalent in an isocratic mode utilizing methanol water (70:30) at pH 5.0 Adjusted to OPA at a flow rate of 1.0ml/min and eluate was monitored at 243nm, with a retention time of 2.584 minutes for Mirabegron. The method was validated and the response was found to be linear in the drug concentration range of 50µg/ml to150 µg/ml for Mirabegron. The values of the correlation coefficient were found to 0.999for Mirabegron. The Limit of Detection(LOD) and Limit of Quantification (LOQ) for Mirabegron were found to be 0.149 and 0.498 respectively. This method was found to be good percentage recovery were found to be 99 indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample so, the method specifically determines the analyte in the sample without interference from excipients of tablet dosage forms. The method was extensively validated according to International Council for Harmonisation(ICH) guidelines for Linearity, Accuracy, Precision, Specificity and