METHOD DEVELOPMENT AND VALIDATION OF IXAZOMIB DRUG BY RP-HPLC IN BULK AND PHARMACEUTICAL DOSAGE FORM

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 28-34
Author(s):  
Yarasani Prashanthi ◽  
◽  
Faheem Ahmed ◽  
Tentu Nageswara Rao ◽  
Botsa Parvatamma ◽  
...  

A novel approach was used for develop and validate a rapid, accurate, and an isocratic RP-HPLC method with PDA detector for the estimation of ixazomib drug in pharmaceutical dosage forms. Ixazomib was seperated using Agilent 4.6*150 mm, 5μm analytical column, a Waters HPLC system (USA) and a mobile phase consisting of water and acetonitrile in the ratio of 40:60 V/V. The flow rate was set to 0.7 mL/min with 10µL injection volume. The column was maintained at ambient temperature, detector was set at wavelength of 274 nm. The retention time of ixazomib was found to be 2.17 min. The system suitability parameters for ixazomib such as theoretical plates and tailing factor were found to be 4146. Linearity was established for ixazomib such as theoretical plates and telling factor were found to be 4146. Linearilty was established for ixazomib in the range of 50-250 µg/ml concentration levels with correlation coefficients (r2) of 0.999. The intra-and inter-day precision % RSD values were found to be 0.47 and 0.31, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 2.03 and 6.17 µg/mL respectively. The method was validated for all of the above parameters according to the International Conference on Harmonization (ICH) guidelines. This method can be used for estimation and analysis of ixazomib drug in active pharmaceutical ingredients and pharmaceuticals.

Author(s):  
G.M. Kadam ◽  
A.L. Puyad ◽  
T.M. Kalyankar

A new, economical, simple, accurate, and precise RP-HPLC method was developed for simultaneous assay and content uniformity determination of Sacubitril and Valsartan in bulk and pharmaceutical dosage form. The separation of Sacubitril and Valsartan was achieved within 6 minutes on Phenomenex Luna C18 250 mm x 4.6mm and 5µm Particle Size, column using Acetonitrile: Methanol: Water (30:55:15% v/v/v) as the mobile phase. Detection was carried out at 250 nm wavelength. The retention time of Sacubitril and Valsartan was found to be 2.361 and 3.304 min, respectively. The validation of the developed method was performed in terms of specificity, accuracy, precision, linearity, the limit of detection, the limit of quantification as mentioned in International Conference on Harmonization (ICH) guidelines. The method showed adequate sensitivity concerning linearity, accuracy, and precision over the range 12-36 μg/ml and 13-39 μg/ml for Sacubitril and Valsartan, respectively. The percentage recoveries obtained for Sacubitril and Valsartan were found to be in the range of 98.00 – 102.00 %. The proposed method is suitable for use in quality-control laboratories for quantitative analysis.


Author(s):  
Heena Ar Shaikh ◽  
Vandana Jain

Objective: A simple, accurate, precise, robust reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of telmisartan and nebivolol hydrochloride (HCl) simultaneously in its combined dosage form.Methods: The compounds were well resolved in an isocratic method using the mobile phase composition of acetonitrile: Buffer (potassium dihydrogen orthophosphate pH adjusted 3.1 with orthophosphoric acid) in a ratio of 40:60 v/v at a flow rate of 1.2 ml/min using C18 Shim-pack (150 mm × 4.6 mm, 5 μ) column. The detection was carried out at 280 nm.Results: The retention time of telmisartan and nebivolol HCl was 4.8 min and 6.5 min, respectively. The developed method was validated by evaluating various validation parameters such as linearity, precision, accuracy, robustness, specificity, limit of detection, and limit of quantification according to the international council for harmonization guidelines. The standard calibration curve was obtained in the concentration range of 24–56 μg/ml for telmisartan and 3–7 μg/ml for nebivolol HCl. The overall average % recovery was found out to be 100.35 for telmisartan and 98.84 for nebivolol HCl.Conclusion: Statistical analysis of the data showed that the method is reproducible and selective for the estimation of telmisartan and nebivolol HCl. The proposed method could be used for analysis of telmisartan and nebivolol HCl in their dosage form.


Author(s):  
Sayyed Nazifa Sabir Ali ◽  
Lajporiya Mobina ◽  
Manjra Mehfuza ◽  
Patel Seema ◽  
Aejaz Ahmed ◽  
...  

Aims: To develop and validate a new, simple, rapid, precise, and accurate An Eco-friendly RP-HPLC and UV-Method Development and Validation for an estimation of Favipiravir in Bulk and pharmaceutical dosage form followed by Forced Degradation Studies. Study Design: This was employed for UV-visible (200-400 nm and 400-800 nm respectively) and RP-HPLC method development using C 18 inertsil column and optimization of variables for Favipiravir estimation in bulk and formulations. Place and Duration of the Study: The present work was carried out at Ali-allana College of Pharmacy, Akkalkuwa between the duration of November-2020 to February-2021. Methodology: UV-Spectroscopic method was developed for the estimation of Favipiravir in the bulk and pharmaceutical dosage form. The solvent selected for the Favipiravir UV analysis was water, the solution in a range of 2-10µg/ml was scanned in the UV region from 200-400 nm and the λmax value was determined. The RP-HPLC method was developed on inertsil ODS-3V C18 150 mm x 4.6mm x 5μ column using buffer pH 3.5: acetonitrile [90:10] as mobile phase at flow rate 1.0 ml/min and PDA detection at 358 nm. Results: The maximum absorbance was observed at 358 nm. The wavelength 358 nm was selected for further analysis of Favipiravir. The calibration curve was determined using drug concentrations ranging from 2-10 µg/ml. The % recovery for accuracy was 100.50-100.76%. The method was to be precise with a % RSD value 0.51-1.37 and 0.77-1.78 for intraday and Interday respectively. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 0.0723 &0.219 µg/ml respectively by UV method. The RP-HPLC method was shown to be linear in the 50-250 μg/ml concentration range. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 2.186 & 6.626 μg/ml respectively. The method was to be precise with a % RSD value 0.25-1.53 and 0.86-1.68 for intraday and inter-day respectively. Conclusion: Here we conclude that the developed UV and RP-HPLC methods are precise, accurate, sensitive, and reproducible for the quantitative estimation of Favipiravir bulk and its formulation. The developed method can be used by the pharmaceutical industries for the routine analysis of Favipiravir, in particular by UV and RP-HPLC. The main features of the proposed method are economic and eco-friendly with less retention time around 5.0 min.


Author(s):  
Ankit Acharya ◽  
N.K. Satish ◽  
L. Manoj ◽  
Renukaradhya Chitti

The main objective of present study is to develop and validate a new, simple, precise and accurate RP-HPLC method for the determination of Darifenacin Hydrobromide (DFH) in bulk and pharmaceutical dosage forms. The separation and quantification of the drug was achieved on a RP C18 column (250×4.6mm, 5μm) using a mobile phase of acetonitrile: buffer (50:50), pH 3.0 ± 0.2 at a flow rate of 1 mL/min with detection of analyte at 287 nm. The separation was achieved with in 4.0 ± 0.3 min. The method showed good linearity in the range of 10-100 μg/mL. The intra and inter day RSD ranged from 0.20-0.58%. The recovery (mean ± SD) of low, medium and high concentrations were 98.50 ± 0.20, 100.27 ± 0.15 and 100.90 ± 0.09 respectively. The limit of detection and limit of quantification were 0.31 and 0.61 μg/mL, respectively. It can be concluded that the present method could be superior over the methods which were reported earlier. Kathmandu University Journal of Science, Engineering and TechnologyVol. 13, No. 1, 2017, Page: 36-44 


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


2020 ◽  
Vol 10 (1) ◽  
pp. 31-38
Author(s):  
Rahul Suryawanshi ◽  
Siddiqua Shaikh ◽  
Snehal Patil

A new, simple, precise, accurate and reproducible Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for Simultaneous estimation of bulk and pharmaceutical formulations. Separation of Mirabegron was successfully achieve , C18, 250X4.6mm, 5µm or equivalent in an isocratic mode utilizing methanol water (70:30) at pH 5.0 Adjusted to OPA at a flow rate of 1.0ml/min and eluate was monitored at 243nm, with a retention time of 2.584 minutes for Mirabegron. The method was validated and the response was found to be linear in the drug concentration range of 50µg/ml to150 µg/ml for Mirabegron. The values of the correlation coefficient were found to 0.999for Mirabegron. The Limit of Detection(LOD) and Limit of Quantification (LOQ) for Mirabegron were found to be 0.149 and 0.498 respectively. This method was found to be good percentage recovery were found to be 99 indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample so, the method specifically determines the analyte in the sample without interference from excipients of tablet dosage forms. The method was extensively validated according to International Council for Harmonisation(ICH) guidelines for Linearity, Accuracy, Precision, Specificity and


Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

Objective: The present study was aimed to develop a rapid, accurate, linear, sensitive and validate stability-indicating high performance liquid chromatographic [RP-HPLC] method for determination of vildagliptin and metformin in pharmaceutical dosage form.Methods: The chromatographic separation was performed on kromasil-C18 column [4.5 x 250 mm; 5 µm] using a mobile phase consisting of 0.05 mmol potassium dihydrogen phosphate buffer: acetonitrile [80:20 v/v], [pH adjusted to 3.5 using orthophosphoric acid]. The flow rate is 0.9 ml/min and the detection was carried out at 263 nm.Results: The chromatographic condition, the peak retention time of metformin and vildagliptin were found to be 2.215 min and 2.600 min respectively. Stress testing was performed in accordance with an international conference on harmonization [ICH] Q1A R2 guidelines. The method was validated as per ICH Q2 R1 guidelines. The calibration curve was found to be linear in the concentration range of 5-17.5 µg/ml and 50-175 µg/ml for vildagliptin and metformin. The limit of detection and quantification was found to be 0.0182 µg/ml and 0.0553 µg/ml for vildagliptin and 0.4451 µg/ml and 1.3490 µg/ml for metformin respectively.Conclusion: A new sensitive, simple and stability indicating reverse-phase high-performance liquid chromatography [RP-HPLC] method has been developed and validated for the determination of vildagliptin and metformin. The proposed method can be used for routine determination of vildagliptin and metformin.


2020 ◽  
Vol 70 (4) ◽  
pp. 465-482
Author(s):  
Béla Kovács ◽  
Francisc Boda ◽  
Ibolya Fülöp ◽  
István Székely-Szentmiklósi ◽  
Éva Katalin Kelemen ◽  
...  

AbstractOffering a systematic and multivariate analysis of the analytical procedure, development and validation of HPLC methods using Quality by Design approach are in the limelight of current research trends. A new, experimental design-aided HPLC method for fampridine was developed and preliminarily validated according to current in-force international guidelines for linearity, accuracy, robustness and precision.The method offers a high throughput sample analysis, with an elution time of 2.9 minutes, and signal detection without excipient interference performed at 262 nm. The method proved to be linear between 1–15 µg mL−1 (R2= 0.9996). The mean recovery was found to be 98.7 ± 1.9 % in the tested range of 2.5–7.5 µg mL−1. Low RSD values (< 1 %) were obtained for both model, intra- and inter-day precision. The limit of detection and limit of quantification were 0.24 and 0.78 µg mL−1, resp. The method proved to be applicable for active substance assay in a pharmaceutical dosage form.


Author(s):  
K Tirumala ◽  
CH.V.S Gautam ◽  
J Gangadhar ◽  
M Jayajeevitha ◽  
Vanitha Prakash K

Reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the estimation of pitavastatin in tablet dosage form. A Phenomenex Luna C18, 150×4.6 mm i.d, 5 µm particle size with mobile phase consisting of buffer 0.01M potassium dihydrogen ortho phosphate pH (3.75) adjusted with dilute orthophosphoric and acetonitrile in the ratio of 20:80 v/v was used. The flow rate was 1.2 mL/min and eluents were monitored at 248 nm. The retention time was 4.1min. The detector response was linear in the concentration of 25-150 µg/mL, with the regression coefficient of 0.9998. Quantification was done by calculating area of the peak and the limit of detection and limit of quantification were 1.9 µg/mL and 5.7 µg/mL respectively. The percentage assay of pitavastatin was 101.1%. The results of study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate which is useful for the routine determination of pitavastatin in bulk drug and in its pharmaceutical dosage forms.