scholarly journals Simulation Model and State Analysis of Ship Transmission Line

2018 ◽  
Vol 25 (s3) ◽  
pp. 36-42
Author(s):  
Yanzhe Hu ◽  
Mengjie Xu ◽  
Yang Li

Abstract In order to discuss the simulation model of the ship transmission line and the state of the transmission line, an early fault model is built according to the evolution principle of the short circuit fault of the transmission line and combining with the fault characteristics of the early fault. A small distributed ship transmission line system is built in MATLAB/ Simulink. Then, combined with the constructed fault module, the original short circuit module, and the load module, the various states (normal state, early fault state, severe early fault state, short circuit state) of the ship transmission line are stimulated, and the features of voltage signal in each state is analysed. It is concluded that, due to the normal operation of the ship transmission line system, the variation characteristics of the flow signal and voltage signal caused by the sudden load mutation, that is, the sudden load and the sudden increase load, are very similar to the changes caused by the early fault. Therefore, in order to find a more accurate early fault detection method, the state is divided into normal state, sudden load state, sudden increase and sudden decrease load state.

Author(s):  
Jéssica Sousa Paixão ◽  
Derblai Casaroli ◽  
João Carlos Rocha dos Anjos ◽  
José Alves Júnior ◽  
Adão Wagner Pêgo Evangelista ◽  
...  

2021 ◽  
Vol 30 (4) ◽  
pp. 74-89
Author(s):  
A. V. Ershov ◽  
V. B. Korobko

The article addresses the problem of bridging the divide between the present-day technological advancement, primarily in the field of normative legal and technical regulation of fire safety, and the qualification of persons, authorized to regulate relations in fire safety assurance (hereinafter — “Authorized persons”) in the context of transition of the state regulation of fire safety relations from an obsolete standard target model to a new analytical and scenario-based (risk-oriented) target model used to make decisions in the area of control over the safe condition of the technosphere in view of a sudden increase in the dynamics of sociocultural processes.The Education and Research Supervision Unit of the State Fire Academy of the EMERCOM of Russia (the Ministry for Civil Defense, Emergencies, and Elimination of Consequences of Natural Disasters), responsible for the drafting of suggestions concerning the implementation of point 10, Minutes № 1 of the meeting of the workgroup of EMERCOM of Russia on May 20, 2019 “Regarding the arrangement of interaction with the management authorities of the institutional firefighting service of executive federal authorities and organizations”, has developed “The list of milestones of professional culture for the persons responsible for regulating relations in the field of fire safety for the period of transition from a standard target model to the risk model of controlling, supervisory, and authorization-related activities” (hereinafter — “the List”).This List represents a basic set of conceptual professional milestones, whose attainment enables authorized persons to re-focus their conscience from an obsolete standard paradigm, used to make decisions in the area of fire safety, to a new risk-oriented one.Given the focus of this article, it defines some, or the most significant, milestones of professional risk-oriented culture of authorized persons.


2018 ◽  
Vol 12 (3) ◽  
pp. 124-130
Author(s):  
Erol Can

This article deals with the energy transmission line system which feeds from solar energy at the MATLAB Simulink. So, direct voltage is considered to be converted as an alternating voltage by a 35-level inverter after the solar power plant which has the power of 110 MW an produce 360 kV of direct voltage. A line which covers 240 km of distance is preferred to transmit electrical power from the A1 point to an A2 point. Due to this, the required mathematical equations are calculated with a circuit analyzing method for the line modeling in the simulation. Experiments on the model are carried out at the MATLAB Simulink after the creation of an energy transmission line. After that, when measurements are made taking into consideration the A2 node; the capacitor voltage, the transformer current, the A2 node current, and the fault current, values are given according to the converted voltage at the frequencies of 100 Hz, 80 Hz, and 50 Hz. The obtained results demonstrate the success of the proposed line system, while power is distributed with eliminated fault at a long distance at different frequencies.


2018 ◽  
Vol 8 (5) ◽  
pp. 3332-3337
Author(s):  
N. M. Khoa ◽  
D. D. Tung

The impact of thyristor controlled series capacitor (TCSC) on distance protection relays in transmission lines is analyzed in this paper. Voltage and current data are measured and collected at the relay locations to calculate the apparent impedance seen by distance protection relays in the different operating modes of the TCSC connected to the line. Short-circuit faults which occur at different locations on the power transmission line are considered in order to locate the fault for the purpose of evaluating the impact of TCSC on the distance protection relay. Matlab/Simulink simulation software is used to model the power transmission line with two sources at the two ends. Voltage source, transmission line, TCSC, voltage and current measurement, and discrete Fourier transform (DFT) blocks are integrated into the model. Simulation results show the impact of TCSC on the distance protection relay and determine the apparent impedance and fault location in the line.


Author(s):  
Arsal Mehmood ◽  
Huzaifa Hassan ◽  
Faraz Ahmed Baig ◽  
Suhail Ahmed Shaikh

Researchers are working on techniques to mitigate failure rates as low as possible to avoid potential harm, sustain high power efficiency for this a considerable number of estimation studies were already performed and several designs of methodologies were being suggested. The transmission line performs the role of the arteries which maintain the process of transporting electricity in the transmission line. That is why it is important to maintain and manage the costs of these tracks.  Surge arrestor and shield wire application are often techniques chosen for defensive strategy in a very technique. By pushing travelling waves towards the electrical equipment mounted on the transmission line, the effects of lightning stoke on the transmission line may cause severe damage to the electrical equipment. In this review, this research study provides a review-based overview of the mechanism of occurrence of lightning along with its impact on the transmission line and the defence methods used to prevent such effects. A MATLAB / SIMULINK 2020a simulation modeling-based analysis for the incidence of lightning on the 33 kV transmission line system is observed in this regard, and a Metal-Oxide surge arrestor-based lightning fault clearance safety scheme is also suggested and discussed.


2019 ◽  
Vol 8 (1) ◽  
pp. 82-90
Author(s):  
L. K. Warne ◽  
S. Campione ◽  
R. S. Coats

This paper considers plane wave coupling to a transmission line consisting of an aerial wire above a conducting ground. Simple circuit models are constructed for the terminating impedances at the ends of the line including radiation effects. We consider the following load topologies: open circuit, short circuit, and grounded rods. Results from the transmission line model with these loads show good agreement with full-wave simulations.  


Sign in / Sign up

Export Citation Format

Share Document