scholarly journals A New Quantitative Analytical Method Development and Validation for the Analysis of Boceprevir in Bulk and Marketed Formulation

Author(s):  
Bhetanabotla Chandramowli ◽  
B.M Syam Kumar ◽  
D.V. R. N. Bhikshapathi ◽  
Bigala B Rajkamal

A simple, precise and accurate RP-HPLC technique was developed and the developed method was validated for the regular analysis of Boceprevir. Chromatographic analysis was performed by selecting X-Terra ODS ( C18) column (4.6 mm i.d. × 250 mm, 5μ), Acetonitrile : Phosphate buffer pH -3 ( 90 : 10% v/v) as mobile phase, 1.0 ml/min as flow rate and 20μl injection volume. The LC chromatographic peak was eluted at 3.6 min at 235 nm as UV detection wavelength. The developed method was validated as per the ICH guidelines and the Validation parameters were specificity, accuracy, linearity, precision, LOD and LOQ. Linear relationship for Boceprevir established in the concentration range of 50 to 150μg/mL. Accuracy in terms of percentage recovery found in the range between 98 to 101%. LOD and LOQ values were found to be 2.3 and 7.123μg/mL respectively. The results of the method established that the new RP-HPLC method is convenient and simple in regular analysis of Boceprevir in bulk and capsule formulation.

Author(s):  
Anusha Shivaraj ◽  
Shireesha Battula

A new simple, specific, accurate, precise RP-HPLC method has been developed for the estimation of Ormeloxifene. The chromatographic separation for Ormeloxifene was achieved with mobile phase containing methanol :ACN(70:30 v/v), agilent C18 column (4.6 x150 mm) 5 μ at room temperature and UV detection at 274nm.The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Ormeloxifene was found to be 2.497min. The method was validated according to ICH guideline for linearity, specificity, precision, accuracy, LOD, LOQ and robustness in accordance with ICH guidelines.


Author(s):  
M. Zeba Baktiyar ◽  
B. Mohammed Ishaq ◽  
Siva Sanker Reddy L ◽  
Sreenivasulu M.

A simple, precise and reproducible RP-HPLC method was developed for the estimation of related substances in tilorone dihydrochloride. Quantification was performed using a Zorbax SB-phenyl column (150 × 4.6mm, 5µ) with mobile phase A: 20mM potassium dihydro phosphate + 2ml of triethylamine, pH 2.30 and mobile phase B: acetonitrile, methanol and water 60: 20: 20% v/v. A gradient program was followed with a run time of 55 minutes at a flow rate of 1.0 ml/min. The column temperature was maintained at 40°C, the injection volume was 10 µl and the detection was performed at 269nm using a PDA detector. The retention time of Tilorone dihydrochloride was found to be 10.36 minutes. The proposed method has been validated according to the ICH guidelines for Linearity, Precision, Accuracy, LOD, and LOQ. The method was linear from 0.157 - 3.934μg/ml for standard, 0.153-3.820μg/ml and 0.166 - 4.140μg/ml for impurities, TLHC01 and TLHC02 respectively. The impurities TLHC01 and TLHC02 have been mapped in all stress conditions. The LOD and LOQ of TLHC01 were found at 1.757μg/ml and 5.857μg/ml and 1.919μg/ml and 6.396μg/ml respectively for TLHC02 respectively. Statistical analysis showed that the method was precision, reproducible, selective, specific and accurate for the analysis of Tilorone dihydrochloride and its impurities. The wide range of linearity, sensitivity, precision, short retention times and simple mobile phase have shown that the method is suitable for the routine quantification of mass impurities of tilorone hydrochloride and its dosage pharmaceutical forms with high precision and accuracy.


2013 ◽  
Vol 49 (2) ◽  
pp. 359-366 ◽  
Author(s):  
Mustafa Çelebier ◽  
Tuba Reçber ◽  
Engin Koçak ◽  
Sacide Altinöz

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


2021 ◽  
Vol 23 (06) ◽  
pp. 992-1000
Author(s):  
Sneha S. Ghule ◽  
◽  
Ashpak M. Tamboli ◽  
Snehal D. Patil ◽  
◽  
...  

A reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Pyridoxamine dihydrochloride and Acetylcysteine in the marketed formulation is developed. Chromatography carried out at 30oc temperature on Agilent Zorbax Bonus-RP (250 x 4.6 mm, 5 µ) coloum. Coloum using a mobile phase 0.1% trifluroacetic acid in water: acetonitrile (80:20v/v) with flow rate 1ml/min (DAD scan at 210nm). Validation parameters such as system suitability, linearity, precision, accuracy are considered as reported International Conference on Harmonization guidelines. The retention times for Pyridoxamine dihydrochloride and Acetylcysteine are 2 min and 3.4 min. The linearity range for Pyridoxamine dihydrochloride and Acetylcysteine is 30-70 µg/ml and 180-420 µg/ml. The %RSD for accuracy was found to be less than 2%. Hence the proposed method was found to be accurate, precise, reproducible, and specific and can be used for simultaneous analysis of these drugs in tablet formulation.


Author(s):  
Krishna Kishore Adireddy ◽  
Srinivasa Rao Baratam ◽  
Nagarjuna Hari Pratap S

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Istradefylline in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. C18G column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 0.1 % orthophosphoric acid and acetonitrile in the ratio of 30: 70 v/v. The method showed a good linear response in the concentration range of 10-90 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 246 nm. The retention time was 3.125 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of istradefylline in tablet formulation.


Author(s):  
Abhishek Agrawal ◽  
Prem Kumar Bichala ◽  
Swapna Singh

RP-HPLC method was developed for the determination for the validation of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. Chromatographic separation was performed on Develosil ODS HG-5 RP C18, 15x4.6mm, 5µm column, with mobile phase comprising of mixture of ACN: Methanol: Citric acid in the ratio of 50:45:5 v/v, at the flow rate 1.0ml/min and the detection was carried out at 296nm. The comprehensive forced stress testing has been carried out as per USP guidelines. The drug Nitazoxanide is subjected to synthetic Benzamide, and the drug Ofloxacin is subject to synthetic Fluoroquinolone. RP- HPLC method was developed to separate analyte from all other degradation peaks. The method was successfully validated as per ICH guidelines for the purpose of conducting studies of the analyte in quality control laboratory. The drug was subjected to different degradation conditions; it was found to be stable in all degradation conditions. The purposed HPLC method was found to be precise, specific, accurate, rapid and economical for the determination of Nitazoxanide and Ofloxacin in pharmaceutical dosage form. The sample recoveries in all formulations were in good agreement with their respective label claims and this method can be used for routine analysis. The linearity range was found to be 0-50 (µg/ml) for Nitazoxanide and 0-50 (µg/ml) for Ofloxacin. Calibration curve was plotted and correlation co-efficient for the drugs found to be 0.999 and 0.997. Hence the results obtained were within the limits.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (05) ◽  
pp. 68-71
Author(s):  
A Lakshmana Rao ◽  
◽  
T. Prasanthi ◽  
E. L Anusha

A simple, accurate and precise RP-HPLC method was developed for the simultaneous estimation of the linagliptin and empagliflozin in tablet dosage form. Chromatogram was run through Kromasil 250 x 4.6 mM, 5mM column, mobile phase containing 0.1% o-phosphoric acid buffer and acetonitrile in the ratio of 60:40%v/v was pumped through column at a flow rate of 1 mL/min. The optimized wavelength was 230 nm. Retention times of linagliptin and empagliflozin were found to be 2.759 min and 2.139 min. %RSD of the Linagliptin and Empagliflozin were found to be 0.5 and 0.6 respectively. Percentage assay was obtained as 99.91% and 100.15% for linagliptin and empagliflozin, respectively. LOD, LOQ values obtained for linagliptin and empagliflozin were 0.23 μg/ml and 0.44 μg/mL and 0.70 μg/mL and 1.34 μg/mL, respectively. Thus, the current study showed that the developed RP-HPLC method is sensitive and selective for the estimation of linagliptin and empagliflozin in combined dosage form.


2019 ◽  
Vol 9 (6-s) ◽  
pp. 127-135
Author(s):  
Amar Deep Ankalgi ◽  
Nitin Kumar Chaudhary ◽  
Pooja Kaushal ◽  
Mahendra Singh Ashawat

Curcumin is the natural herb that shows effect in the treatment of cancer and rheumatoid arthritis and methotrexate is well known anticancer and anti-rheumatoid drug. Literature survey reveals that there was no method available for the selected drug combination. So, here an attempt has been made to develop simple, rapid and economic method for simultaneous estimation of methotrexate and curcumin in bulk drug by using RP-HPLC method. The percentage assay from optimized method was found to be 99.68% and 99.76% for methotrexate and curcumin respectively.  The proposed method was validated for  linearity, accuracy, precision and robustness according to ICH guidelines and were found to be   within the standard range. Keywords: RP- HPLC, methotrexate, Linearity, anticancer


2018 ◽  
Vol 34 (5) ◽  
pp. 2554-2561
Author(s):  
D. China Babu ◽  
C. Madhusudhana Chetty ◽  
S. K. Mastanamma

A selective, sensitive RP-HPLC method was developed for the simultaneous estimation of the Ertugliflozin (ETR) and Sitagliptin (SGT) in bulk and its dosage form. The separation and determination was carried on water’s C18 column capacitate (250X4.6 mm, 5 µm particle size), retention times of Ertugliflozin and Sitagliptin were found to be 2.39 and 4.60 min respectively. The wavelength was fixed at 215nm with PDA detection. The mobile phase was consisted mixture of 0.5 mM potassium dihydrogen ortho phosphate buffer: Methanol in the ratio of 55:45 v/v, pH 5.3 was adjusted with HCl and flow of mobile phase was maintained 1mL/min. The calibration curve was linear and regression co-efficient (R2) value found to be 0.999 and concentration ranging from 37.5-112.5 and 250-750 µg/mL for Ertugliflozin & Sitagliptin respectively. The quantization limit and detection limit of the method were found 0.1 & 0.3 µg/ml and 0.4&1µg/ml for Ertugliflozin & Sitagliptin.


2020 ◽  
Vol 11 (4) ◽  
pp. 6826-6833
Author(s):  
Vijey Aanandhi M ◽  
Elancheziyan K ◽  
Yamini R ◽  
Prakash Chand T ◽  
Aysha Jadeera K A ◽  
...  

The purpose or intent of this current study was to establish a fast and sensitive HPLC technique for the perseverance of Fludrocortisone acetate and utilizing best frequently used HPLC technique. This method had been validated as per the ICH requirements  to assure that the method consistently meets the predetermined specifications and quality attributes.Utilizing filtered and degassed pH 3.0 Phosphate buffer and Acetonitrile in the ratio 90:10 as a Mobile phase-A and pH 3.0 Phosphate buffer and Acetonitrile in the ratio 65:35 as a Mobile phase-B the established RP-HPLC technique was done. The separation was achieved by using Waters, X-Bridge Shield RP18, (150 X 4.6-mm), 3.5-µm column. Run time and Flow rate was set 45minutes and 1.2mL/min. Injection volume 100µL and wavelength was set 240nm.The correlation coefficient square for fludrocortisones acetate and Fludrocortisone Impurity was found to be 0.9991 and 0.99997. The SD and %RSD for Fludrocortisone Impurity was found to be 0.02 and 1.48 represents method precision. Following validated parameters lies within the limit. Hence, the developed method was precise, simple, fast and accurate.