Analisa Pola Kegagalan Balok Beton Menggunakan GFRP Bar Tanpa Selimut Beton

2020 ◽  
Vol 24 (1) ◽  
pp. 11-16
Author(s):  
Saddam - Husein ◽  
Rudy Djamaluddin ◽  
Rita Irmawaty ◽  
Kusnadi Kusnadi

SADDAM HUSEIN. Analisa Pola Kegagalan Balok Beton Menggunakan GFRP Bar Tanpa Selimut Beton (dibimbing oleh Rudi Djamaluddin dan Rita Irmawaty) Struktur beton bertulang yang menggunakan tulangan baja pada daerah korosif, menjadi rawan terhadap kerusakan atau penurunan kekuatannya akibat korosi.Korosi pada tulangan baja merupakan salah satu faktor penyebab menurunnya kekuatan struktur beton bertulang. Salah satu material yang dikembangkan mengatasi korosi adalah penggunaan material tulangan GFRP (Glass Fiber Reinforced Polymer). Penelitian ini bertujuan untuk menganalisa kapasitas lentur dan pola kegagalan balok beton tanpa selimut dengan menggunakan material tulangan GFRP bar.   Desain penelitian merupakan eksperimental laboratorium dengan rekapitulasi sebanyak 6 sampel yang terdiri dari 2 Balok beton menggunakan tulangan baja dengan selimut beton, 2 balok beton menggunakan tulangan GFRP bar dengan selimut beton, 2 balok beton menggunakan GFRP bar tanpa selimut beton. Metode pengujian dilakukan dengan dengan pengujian lentur statik monotonik dan Analisis data menggunakan uji kondisi retak awal dan kondisi ultimit.   Hasil penelitian ini menunjukkan bahwa kapasitas lentur pada balok dengan tulangan GFRP bar lebih besar dibandingkan dengan balok tulangan baja dan mampu meningkatkan kapasitas lentur balok dalam menahan beban sebesar 39.76 %, pola kegagalan beton yang terjadi pada balok tulangan baja mengalami kegagalan lentur tekan ditandai dengan retakan yang terjadi pada sisi tertekan dan membentuk retakan tegak dengan sumbu netral beton yang tertekan, sedangkan pada balok beton tulangan GFRP tanpa selimut mengalami kegagalan keruntuhan tekan geser dengan kondisi tulangan berdeformasi (bi-linear) dengan retak miring dan secara tiba-tiba menjalar menuju sumbu netral beton yang tertekan sehingga terjadilah keruntuhan secara tiba-tiba.     SADDAM HUSEIN.Failure mode analysis of concrete Beams Using GFRP rebar Without concrete cover (supervised by Rudi Djamaluddin and Rita Irmawaty)   Reinforced concrete that uses rebar steel in corrosive areas, are prone to damage or decreased strength due to corrosion. Corrosion in the steel reinforcement is one of the factors that decreasing strength of reinforced concrete. One of the materials developed to overcome corrosion is the use of GFRP (Glass Fiber Reinforced Polymer) reinforcement material. This study aims to analyze the flexural capacity and failure mode of concrete beams without concrete cover using material GFRP bar as reinforcement.   The research design was an experimental laboratory with a recapitulation of 6 samples consisting of 2 beams using steel reinforcement with concrete cover.2 concrete beams using reinforcement GFRP bar with concrete cover, 2 beams using GFRP bars without concrete cover. The  research method uses the monotonic static flexure and analyzing the data using the initial crack condition and ultimate conditions test.   The results of the research indicate the flexural capacity of the beams with GFRP bar reinforcement is higher than steel reinforcement beams and can increase 39.76% of the flexural capacity of the beams in holding loads , the failure mode analysis occurs in steel reinforcing beam experiences compressive failure. Failure was characterized  by cracks that occur on the depressing side and form an upright crack with the neutral axis of the compressed concrete, whereas in GFRP reinforced concrete beams without concrete cover, failure of shear compression with conditions of deformed reinforcement (bi-linear) with sloping cracks and suddenly spread towards the neutral axis of the compressed concrete so that there was a sudden collapse.

2016 ◽  
Vol 707 ◽  
pp. 51-59 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Rania Khattab

The behaviour of reinforced concrete beam strengthened with Carbon Fiber Reinforced Polymer (CFRP) and Glass fiber reinforced polymer GFRP laminates was investigated using finite element models and the results are presented in this paper. The numerical investigation assessed the effect of the configuration of FRP strengthening laminates on the behaviour of concrete beams. The load-deflection behaviour, and ultimate load of strengthened beam were compared to those of un-strengthened concrete beams. It was shown that using U-shaped FRP sheets increased the ultimate load. The stiffness of the strengthed beam also increased after first yielding of steel reinforcing bars. At was also observed that strengthening beams with FRP laminates to one-fourth of the beam span, modifies the failure of the beam from shear-controlled near the end of the unstrengthened beam, to flexure-controlled near mid-span. CFRP produced better results compared GFRP in terms of the ability to enhance the behavior of strengthenened reinforced concrete beams.


Polymers ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2110
Author(s):  
Hakem Alkhraisha ◽  
Haya Mhanna ◽  
Noor Tello ◽  
Farid Abed

The main objective of this study was to investigate experimentally and numerically the behavior of basalt fiber-reinforced polymer (BFRP) reinforcement exposed to a combination of ultraviolet rays, humidity, and rain. Specifically, the effects of the previously stated harsh exposure on the serviceability performance and flexural capacity of BFRP reinforced concrete beams was examined. Holding the exposure parameter constant, the study also evaluated the effects of reinforcement ratio and beam detailing on the flexural capacity and the bond-dependent coefficient (kb) of the beams. Seven beams were cast and tested, four of which were reinforced with exposed BFRP bars, two were reinforced with unexposed BFRP bars, and one specimen was cast and reinforced with steel bars to serve as a benchmark specimen. The results indicate that the kb factor was averaged to be 0.61 for all the beams. Test results also indicate that increasing the reinforcement ratio did not result in a directly proportional increase in the moment capacity. The period of exposure did not cause any significant impact on the behavior of the over-reinforced beams. Thus, a finite element model was created to simulate the impact of exposure on the behavior of under-reinforced BFRP reinforced concrete beams.


2008 ◽  
Vol 1 (3) ◽  
pp. 285-295 ◽  
Author(s):  
D. H. Tavares ◽  
J. S. Giongo ◽  
P. Paultre

The use of fiber reinforced polymer (FRP) bars is one of the alternatives presented in recent studies to prevent the drawbacks related to the steel reinforcement in specific reinforced concrete members. In this work, six reinforced concrete beams were submitted to four point bending tests. One beam was reinforced with CA-50 steel bars and five with glass fiber reinforced polymer (GFRP) bars. The tests were carried out in the Department of Structural Engineering in São Carlos Engineering School, São Paulo University. The objective of the test program was to compare strength, reinforcement deformation, displacement, and some anchorage aspects between the GFRP-reinforced concrete beams and the steel-reinforced concrete beam. The results show that, even though four GFRP-reinforced concrete beams were designed with the same internal tension force as that with steel reinforcement, their capacity was lower than that of the steel-reinforced beam. The results also show that similar flexural capacity can be achieved for the steel- and for the GFRP-reinforced concrete beams by controlling the stiffness (reinforcement modulus of elasticity multiplied by the bar cross-sectional area - EA) and the tension force of the GFRP bars.


2016 ◽  
Vol 9 (1) ◽  
pp. 123-152
Author(s):  
M. M. VIEIRA ◽  
A. R. S. SANTOS ◽  
A. M. MONT'ALVERNE ◽  
L. M. BEZERRA ◽  
L. C. S. MONTENEGRO ◽  
...  

The use of carbon fiber reinforced polymer (CFRP) has been widely used for the reinforcement of concrete structures due to its practicality and versatility in application, low weight, high tensile strength and corrosion resistance. Some construction companies use CFRP in flexural strengthening of reinforced concrete beams, but without anchor systems. Therefore, the aim of this study is analyze, through an experimental program, the structural behavior of reinforced concrete beams flexural strengthened by CFRP without anchor fibers, varying steel reinforcement and the amount of carbon fibers reinforcement layers. Thus, two groups of reinforced concrete beams were produced with the same geometric feature but with different steel reinforcement. Each group had five beams: one that is not reinforced with CFRP (reference) and other reinforced with two, three, four and five layers of carbon fibers. Beams were designed using a computational routine developed in MAPLE software and subsequently tested in 4-point points flexural test up to collapse. Experimental tests have confirmed the effectiveness of the reinforcement, ratifying that beams collapse at higher loads and lower deformation as the amount of fibers in the reinforcing layers increased. However, the increase in the number of layers did not provide a significant increase in the performance of strengthened beams, indicating that it was not possible to take full advantage of strengthening applied due to the occurrence of premature failure mode in the strengthened beams for pullout of the cover that could have been avoided through the use of a suitable anchoring system for CFRP.