scholarly journals OPTIMIZATION OF THE 1050nm PUMP POWER AND FIBER LENGTH IN SINGLE-PASS AND DOUBLE-PASS THULIUM DOPED FIBER AMPLIFIERS

2009 ◽  
Vol 14 ◽  
pp. 431-448 ◽  
Author(s):  
Siamak Dawazdah Emami ◽  
Sulaiman Wadi Harun ◽  
Faidz Abd-Rahman ◽  
Hairul Azhar Abdul-Rashid ◽  
Siti Aida Daud ◽  
...  
2006 ◽  
Vol 15 (03) ◽  
pp. 303-307
Author(s):  
HARITH AHMAD ◽  
SULAIMAN WADI HARUN

A double-pass erbium-doped fiber amplifier (EDFA) based on a depressed cladding erbium-doped fiber, which operates in the short wavelength (S-band) region is proposed and demonstrated. This amplifier provides a small signal gain as high as 30 dB at 1500 nm, using only 15 m depressed cladding erbium-doped fiber (EDF) and 130 mW of 980 nm pump power. Compared to the single-pass configuration, this amplifier shows a gain enhancement of about 14 dB for pump powers above 120 mW. However, noise figures penalties of less than 0.9 dB are obtained for these pump powers. The proposed double-pass amplifier will play an important role in the development of a practical S-band EDFA from the perspective of economical usage of EDF and pump power.


2009 ◽  
Vol 2009 ◽  
pp. 1-5 ◽  
Author(s):  
Chun Jiang ◽  
Li Jin

We present for the first time a theoretical model ofEr3+-Tm3+-Pr3+codoped fiber pumped with both 800 nm and 980 nm lasers to explore possibility of this co-doped system as all-wave fiber amplifier. The rate and power propagation equations of the model are solved numerically and the dependence of the gains at 1310, 1470, 1530, 1600, 1650 nm windows on fiber length is calculated. The results show that with pump power of 200 mW/200 mW, when the concentrations ofPr3+,Tm3+,Er3+are around1.7×1024,3.9×1024,1.2×1024(ions/m3), respectively, the signals at 1310, 1470, 1530, 1600, 1650 nm may be nearly equally amplified with gain of 13–16.0 dB in the active fiber with length of 23.5 m; the co-doping concentrations and fiber length and pump powers may be further optimized to reduce the ripple.


Author(s):  
Maryam Ilchi-Ghazaani ◽  
Parviz Parvin ◽  
Sajjad Mohammadian ◽  
Reza Poozesh ◽  
Kamran Hejaz
Keyword(s):  

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Md. Asraful Sekh ◽  
Mijanur Rahim ◽  
Anjumanara Begam

Abstract In this paper, design of erbium-doped fiber amplifiers (EDFA) based 16 channel wavelength-division multiplexing (WDM) system for different pump powers and input signal levels using counter propagating pumping scheme is reported. Wavelength range between 1548 and 1560 nm in C-band with channel spacing of 0.75 nm at a bit rate of 10 Gbps are used. Input power given to all the channels is taken between −20 and −35 dBm with 3 dBm variation. Pump power levels between 100 and 500 mW at 980 nm wavelength are used. Low gain flatness with high gains and low noise figures are achieved with the proposed scheme.


2010 ◽  
Vol 30 (3) ◽  
pp. 681-685
Author(s):  
宋梅梅 Song Meimei ◽  
冯素娟 Feng Sujuan ◽  
毛庆和 Mao Qinghe

2014 ◽  
Vol 989-994 ◽  
pp. 3790-3793
Author(s):  
Hai Dong Wu ◽  
Jin Song Guo ◽  
Yun Wen Wu ◽  
Zhao Xia Wang

Bandwidth enhancement and response flattening of wavelength conversion based on single-pass and double-pass cascaded second harmonic generation and difference frequency generation in step-segmented quasi-phase matched (QPM) gratings are investigated. For the same waveguide length, high conversion efficiency, flat response and broad signal bandwidth can be obtained simultaneously by optimizing the poling period of the step-segmented QPM structure. The conversion bandwidths in a 3-cm-long five-step-segmented waveguide are 134 nm for single-pass scheme and 132 nm for the double-pass one, respectively, which are both over the whole conventional band and long-wavelength band. The ripple on the matching response can keeps less than 0.2 dB as well.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Raheleh Nowzari ◽  
Hasan Saygin ◽  
L.B.Y. Aldabbagh

Abstract An experimental study was conducted to evaluate the thermal efficiency of a modified solar air heater. In the current design, air enters the collector through holes in front glass, passes through mesh layers, and exits at the backside of the air heater. A centrifugal fan was used to circulate air through the system. The design offers low construction costs and less solar radiation reflected from the collector. The modified collector was examined with various bed heights (30, 50, and 70 mm) and different mass flowrates of air varying from 0.011 kg/(s m2) to 0.043 kg/(s m2). The results showed that a counter flow collector with pierced cover had 5.6–9.7% higher efficiency than the single-pass one. The average efficiencies of the current design collector were found to be 55.2%, 44.6%, and 39.7% for the single-pass and 60.8%, 50.9% and 45.4% for the double-pass collector at 30, 50, and 70 mm bed heights and airflow rate of 0.043 kg/(s m2), respectively. The thermohydraulic efficiency, temperature difference, and perforated cover surface temperature were analyzed at each test and their effects on the system performance were evaluated. The highest amount of pressure drop through the collector was measured in the collector with a 70-mm bed height and a maximum air flowrate.


Sign in / Sign up

Export Citation Format

Share Document